TL;DR

This paper presents the design and fabrication of a highly integrated silicon stave for the STAR experiment at RHIC, featuring 6 custom silicon sensors and 36 APV front-end chips bonded via 4,608 wire bonds on a Kapton-based hybrid substrate. The stave uses a carbon fiber-reinforced composite structure with embedded cooling, achieving 95% channel functionality in the final detector with precise optical surveying for sub-100 µm alignment accuracy.

ABSTRACT

We present the design of a detector used as a particle tracking device in the STAR experiment at the RHIC collider of Brookhaven National Laboratories. The "stave," 24 of which make up the completed detector, is a highly mechanically integrated design comprised of 6 custom silicon sensors mounted on a Kapton substrate. 4608 wire bonds connect these sensors to 36 analog front-end chips which are mounted on the same substrate. Power and signal connectivity from the hybrid to the front-end chips is provided by wire bonds. The entire circuit is mounted on a carbon fiber base co-cured to the Kapton substrate. We present the unique design challenges for this detector and some novel techniques for overcoming them.

Motivation & Objective

  • To develop a low-mass, high-integration particle tracking detector for the STAR experiment at RHIC's high-radiation environment.
  • To minimize material budget in the detector while ensuring robust electrical and thermal performance.
  • To achieve precise mechanical and electrical integration of silicon sensors, front-end chips, and cooling systems in a flexible, co-cured stave structure.
  • To ensure reliable wire bonding and long-term stability under radiation and thermal stress using UV-resistant encapsulation.

Proposed method

  • The stave uses a 2-layer 0.5 oz. copper-on-Kapton hybrid substrate with selective plating through vias to reduce mass.
  • 36 APV analog front-end chips and 6 silicon sensors are wire-bonded to the hybrid, with power, signal, and control lines routed via differential pairs and I2C buses.
  • A carbon fiber honeycomb and foam core are co-cured to the hybrid, with an aluminum cooling tube embedded beneath the APV chips to manage heat.
  • Novec 7200 synthetic fluid is used as a non-damaging, low-vapor-pressure coolant to prevent detector contamination in case of leaks.
  • Optical surveying with a Nikon VM-150 achieves ~5 µm in-plane and ~50 µm out-of-plane position accuracy for sensor alignment.
  • Dow Corning Sylgard 186 elastomer is used to encapsulate wire bonds post-assembly to prevent damage, replacing a UV-curable encapsulant that degraded APV chips.

Experimental results

Research questions

  • RQ1How can a high-density, low-mass silicon tracking stave be designed to minimize material interactions in a high-radiation collider environment?
  • RQ2What techniques enable reliable wire bonding and thermal management in a co-cured carbon fiber and Kapton hybrid structure?
  • RQ3How can electrical performance and signal integrity be maintained across 4,608 wire bonds in a compact, flexible stave design?
  • RQ4What encapsulation method ensures long-term reliability of wire bonds without degrading sensitive APV front-end chips?
  • RQ5How can sub-100 µm mechanical alignment accuracy be achieved for detector staves prior to installation?

Key findings

  • The final detector achieved 95% channel functionality, with nearly all staves successfully integrated into the STAR experiment.
  • Optical surveying achieved a position accuracy of approximately 5 µm in-plane and 50 µm out-of-plane for each stave.
  • The use of Novec 7200 fluid as a coolant eliminated risk of detector damage in case of leaks due to its low vapor pressure and high resistivity.
  • UV-curable encapsulant Dymax 9001-E-V3.1 damaged APV chips during curing, leading to the adoption of room-temperature-cured Dow Corning Sylgard 186.
  • The stave design successfully managed thermal loads with 14 thermal vias per APV chip placement site, reducing thermal resistance.
  • Post-assembly testing and optical surveying enabled identification and correction of bonding issues, ensuring high reliability before installation.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.