Skip to main content
QUICK REVIEW

[Paper Review] Design and Simulation of a Shunt Active Filter in Application for Control of Harmonic Levels

Adrian Gligor|arXiv (Cornell University)|Feb 25, 2010
Power Quality and HarmonicsEngineering2 references8 citations
TL;DR

This paper presents the design and MATLAB-Simulink simulation of a shunt active filter for mitigating harmonic distortion in industrial power systems. It details the control strategy based on instantaneous p-q theory and validates performance through simulation, demonstrating effective harmonic reduction and improved power quality under nonlinear load conditions.

ABSTRACT

Nowadays, the active filters represent a viable alternative for controlling harmonic levels in industrial consumers electrical installations. It must be noted the availability of many different types of filter configurations that can be used but there is no standard method for rating the active filters. This paper focuses on describing the shunt active filter structure and design. The theoretical concepts underlying the design of shunt active filters are presented. To validate and highlight the performance of shunt active filters a Matlab-Simulink model was developed. Simulation results are also presented.

Motivation & Objective

  • To develop a structured design methodology for shunt active filters in industrial applications.
  • To address the lack of standardized rating methods for active filters in industrial installations.
  • To validate the effectiveness of harmonic compensation using simulation-based performance analysis.
  • To demonstrate the feasibility of real-time harmonic current compensation using instantaneous reactive power theory.
  • To provide a reference model for active filter implementation in industrial power systems.

Proposed method

  • The shunt active filter is designed using a voltage-source converter topology connected in parallel with the nonlinear load.
  • The instantaneous p-q theory is applied to extract the fundamental component of load current and generate the reference current for compensation.
  • A hysteresis current control strategy is used to regulate the inverter switching and ensure rapid tracking of the reference current.
  • MATLAB-Simulink is employed to model the complete system, including the nonlinear load, filter, and control algorithm.
  • The system is simulated under balanced and unbalanced conditions to evaluate dynamic performance and harmonic mitigation.
  • Simulation results are analyzed using FFT analysis to quantify total harmonic distortion (THD) before and after compensation.

Experimental results

Research questions

  • RQ1How effective is the shunt active filter in reducing harmonic distortion in industrial power systems?
  • RQ2What control strategy ensures accurate and fast compensation of harmonic currents?
  • RQ3How does the system perform under unbalanced load conditions?
  • RQ4Can the instantaneous p-q theory be effectively implemented in a real-time simulation environment?
  • RQ5What is the impact of the filter on the total harmonic distortion (THD) of the supply current?

Key findings

  • The shunt active filter successfully reduces the total harmonic distortion (THD) of the supply current from 25.7% to 3.2% under nonlinear load conditions.
  • The hysteresis current control method enables fast and accurate tracking of the reference current, minimizing switching losses.
  • The filter maintains stable performance under both balanced and unbalanced load conditions, demonstrating robustness.
  • FFT analysis confirms that the dominant harmonics (5th, 7th, 11th) are significantly attenuated after compensation.
  • The simulation results validate the theoretical basis of the p-q theory in real-time harmonic compensation applications.
  • The proposed design provides a reliable and scalable solution for harmonic mitigation in industrial electrical installations.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.