[Paper Review] Design of Three-Phase Hybrid Active Power Filter for Compensating the Harmonic Currents of Three-Phase System

Zubair Ahmed Memon, Muhammad Aslam Uqaili|arXiv (Cornell University)|Apr 9, 2016
Power Quality and HarmonicsEngineering20 references6 citations
TL;DR

This paper proposes a three-phase hybrid active power filter using the instantaneous pq theory to detect harmonic currents and a hysteresis current controller to track the reference current. Simulation results confirm effective harmonic mitigation, reducing total harmonic distortion and improving power quality in three-phase systems as per IEEE 519 standards.

ABSTRACT

Power quality standards (IEEE-519) require to limit the total harmonic distortion within satisfactory range caused by power electronic based devices. Our work deals with the design of hybrid active filter to reduce current perturbations produced by power electronics based devices. The Instantaneous Active and Reactive Power Method (pq) is used to perform the identification of disturbing currents. The pq algorithm creates a reference current, whereas, this reference current is tracked by the current of the voltage source converter. The currents of the voltage source converter are controlled by hysteresis controller. Simulation results showed that the hybrid active filter can compensate the harmonic currents effectively and improve power quality.

Motivation & Objective

  • To address power quality issues caused by harmonic currents from power electronic devices in three-phase systems.
  • To design a hybrid active power filter that effectively compensates for harmonic currents while maintaining system stability.
  • To implement the instantaneous pq theory for accurate detection of harmonic components in load currents.
  • To ensure precise tracking of the reference current using a hysteresis current controller in the voltage source converter.
  • To validate the filter’s performance in reducing total harmonic distortion (THD) to meet IEEE 519 standards.

Proposed method

  • The instantaneous active and reactive power (pq) theory is applied to extract the fundamental and harmonic components of the load current.
  • The pq algorithm generates a reference current signal representing the harmonic component to be compensated.
  • A voltage source converter (VSC) is used to inject a compensating current equal in magnitude but opposite in phase to the detected harmonic current.
  • A hysteresis current controller regulates the switching of the VSC to ensure fast and accurate tracking of the reference current.
  • The system is simulated in a three-phase configuration to evaluate harmonic mitigation performance.
  • The filter combines a passive LC filter with an active front-end to reduce the rating and cost of the active component.

Experimental results

Research questions

  • RQ1How effectively can the pq theory detect harmonic currents in a three-phase system with nonlinear loads?
  • RQ2Can a hysteresis current controller accurately track the reference current generated by the pq method?
  • RQ3To what extent does the hybrid active filter reduce total harmonic distortion (THD) in the supply current?
  • RQ4How does the combination of passive and active filtering improve system efficiency and reduce active filter rating?
  • RQ5Does the proposed filter design meet the harmonic limits specified in IEEE 519 for power quality?

Key findings

  • The pq theory successfully identifies harmonic components in the load current with high accuracy, enabling effective compensation.
  • The hysteresis current controller ensures fast and stable tracking of the reference current, minimizing tracking error.
  • The hybrid filter design significantly reduces total harmonic distortion (THD) in the supply current, improving power quality.
  • The integration of passive and active filtering reduces the required rating of the active converter, enhancing cost-effectiveness.
  • Simulation results confirm that the filter maintains harmonic current levels within acceptable limits as per IEEE 519 standards.
  • The system demonstrates robust performance under varying load conditions, validating its practical applicability.