Skip to main content
QUICK REVIEW

[Paper Review] Detecting, Localising and Classifying Polyps from Colonoscopy Videos using Deep Learning

Yu Tian, Leonardo Zorrón Cheng Tao Pu|arXiv (Cornell University)|Jan 9, 2021
Colorectal Cancer Screening and DetectionMedicine58 references11 citations
TL;DR

This paper presents a deep learning system for real-time detection, localization, and classification of polyps in colonoscopy videos, using few-shot anomaly detection to identify polyp-containing frames while rejecting distractors like blurry images, feces, and water jets. The method achieves state-of-the-art performance with improved accuracy and interpretability through uncertainty estimation and confidence calibration, particularly when rejecting low-confidence predictions.

ABSTRACT

In this paper, we propose and analyse a system that can automatically detect, localise and classify polyps from colonoscopy videos. The detection of frames with polyps is formulated as a few-shot anomaly classification problem, where the training set is highly imbalanced with the large majority of frames consisting of normal images and a small minority comprising frames with polyps. Colonoscopy videos may contain blurry images and frames displaying feces and water jet sprays to clean the colon -- such frames can mistakenly be detected as anomalies, so we have implemented a classifier to reject these two types of frames before polyp detection takes place. Next, given a frame containing a polyp, our method localises (with a bounding box around the polyp) and classifies it into five different classes. Furthermore, we study a method to improve the reliability and interpretability of the classification result using uncertainty estimation and classification calibration. Classification uncertainty and calibration not only help improve classification accuracy by rejecting low-confidence and high-uncertain results, but can be used by doctors to decide how to decide on the classification of a polyp. All the proposed detection, localisation and classification methods are tested using large data sets and compared with relevant baseline approaches.

Motivation & Objective

  • To develop an automated system that detects, localizes, and classifies polyps in colonoscopy videos to support early colorectal cancer diagnosis.
  • To address the challenge of highly imbalanced datasets where normal frames vastly outnumber polyp-containing frames.
  • To improve reliability and interpretability by integrating classification uncertainty and confidence calibration into the polyp classification pipeline.
  • To reject false positives from non-polyp frames such as blurry images, feces, and water jet sprays before polyp detection.
  • To reduce reliance on post-procedural histopathology by enabling accurate in-procedural polyp classification.

Proposed method

  • A few-shot anomaly detection framework (FSAD-Net) is used to detect polyp-containing frames, trained to maximize mutual information between normal images and their embeddings.
  • An outlier-robust classifier is applied to reject frames with blur, feces, or water jet sprays before polyp detection.
  • A one-stage deep learning model performs simultaneous polyp localization (bounding box) and classification into five classes using state-of-the-art object detection architectures.
  • Bayesian and calibrated classification heads are employed to estimate prediction uncertainty and improve calibration, reducing miscalibration errors.
  • A rejection strategy is applied to discard low-confidence and high-uncertainty predictions, improving average precision and accuracy.
  • The system is evaluated using 5-fold cross-validation on large-scale Australian and Japanese colonoscopy datasets with rigorous ablation and comparison to baseline methods.

Experimental results

Research questions

  • RQ1Can few-shot anomaly detection effectively identify polyp-containing frames in colonoscopy videos despite extreme class imbalance?
  • RQ2How can non-polyp distractors such as feces, water jets, and blurry frames be effectively rejected to improve detection reliability?
  • RQ3To what extent does uncertainty estimation and confidence calibration improve the accuracy and interpretability of polyp classification?
  • RQ4How does the performance of the one-stage localization and classification model compare to methods relying on manually annotated polyps?
  • RQ5Can the integration of uncertainty and calibration reduce calibration errors and improve robustness in clinical deployment?

Key findings

  • FSAD-Net achieved state-of-the-art few-shot anomaly detection performance on colonoscopy data, outperforming existing imbalanced learning and anomaly detection methods.
  • The integration of uncertainty estimation and confidence calibration reduced Expected Calibration Error (ECE) and Mean Calibration Error (MCE), especially for non-Bayesian models.
  • Rejecting 30% of the lowest-confidence and highest-uncertainty test samples improved classification accuracy by up to 49% and average precision (AP) by up to 48%.
  • The one-stage localization and classification model achieved high performance, with a small accuracy gap (due to mislocalization) compared to a method using manually detected polyps.
  • The system's inference time is under 0.1 seconds per image for detection and localization, but confidence calibration adds significant latency (2.17s per image), indicating a need for optimization.
  • The method generalizes reasonably across domains, though future work is needed to improve zero-shot generalization using domain adaptation and generalization techniques.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.