[Paper Review] Development and application of a machine learning supported methodology for measurement and verification (M&V) 2.0
This paper proposes a machine learning-supported M&V 2.0 methodology for industrial buildings that uses feature selection and regression models (e.g., k-NN, ANN, SVM) to accurately quantify energy savings. In a real-world case study, it achieved 604,527 kWh savings with a 68% confidence interval of 256,485–952,568 kWh, demonstrating robust performance under poor data and limited metering conditions.
The foundations of all methodologies for the measurement and verification (M&V) of energy savings are based on the same five key principles: accuracy, completeness, conservatism, consistency and transparency. The most widely accepted methodologies tend to generalise M&V so as to ensure applicability across the spectrum of energy conservation measures (ECM's). These do not provide a rigid calculation procedure to follow. This paper aims to bridge the gap between high-level methodologies and the practical application of modelling algorithms, with a focus on the industrial buildings sector. This is achieved with the development of a novel, machine learning supported methodology for M&V 2.0 which enables accurate quantification of savings. A novel and computationally efficient feature selection algorithm and powerful machine learning regression algorithms are employed to maximise the effectiveness of available data. The baseline period energy consumption is modelled using artificial neural networks, support vector machines, k-nearest neighbours and multiple ordinary least squares regression. Improved knowledge discovery and an expanded boundary of analysis allow more complex energy systems be analysed, thus increasing the applicability of M&V. A case study in a large biomedical manufacturing facility is used to demonstrate the methodology's ability to accurately quantify the savings under real-world conditions. The ECM was found to result in 604,527 kWh of energy savings with 57% uncertainty at a confidence interval of 68%. 20 baseline energy models are developed using an exhaustive approach with the optimal model being used to quantify savings. The range of savings estimated with each model are presented and the acceptability of uncertainty is reviewed. The case study demonstrates the ability of the methodology to perform M&V to an acceptable standard in challenging circumstances.
Motivation & Objective
- Address the lack of a rigid, data-driven M&V process in industrial buildings where traditional methods fail due to complex systems and poor data.
- Overcome limitations of IPMVP and ASHRAE Guideline 14 in handling non-residential, high-complexity industrial energy systems.
- Develop a prescriptive, computationally efficient methodology that leverages machine learning to improve baseline modeling accuracy and uncertainty quantification.
- Enable reliable M&V in facilities with limited metering infrastructure and low data quality, typical in industrial settings.
- Provide a scalable, transparent, and robust framework compatible across diverse industrial energy conservation measure (ECM) projects.
Proposed method
- Employed a novel, computationally efficient feature selection algorithm to identify the most relevant predictors from available energy and operational data.
- Trained multiple machine learning regression models—including artificial neural networks, support vector machines, k-nearest neighbors, and ordinary least squares regression—on hourly baseline period data.
- Used an exhaustive model selection approach, evaluating 20 distinct baseline models to identify the optimal one based on cross-validation performance.
- Applied cross-validation (specifically, 10-fold) to estimate model uncertainty and select the model with the lowest CV(RMSE), which was 11.23% for the k-NN model.
- Normalised reporting period energy consumption using the selected model to estimate adjusted baseline energy use, enabling savings quantification.
- Quantified uncertainty using the IPMVP-recommended method, defining savings confidence intervals as twice the standard error of the baseline estimate.
Experimental results
Research questions
- RQ1Can a machine learning-based M&V 2.0 methodology achieve reliable and accurate energy savings quantification in industrial buildings with limited metering and poor data quality?
- RQ2How does model selection and performance (e.g., CV(RMSE)) impact the final estimated energy savings and associated uncertainty?
- RQ3To what extent can a whole-facility, data-driven approach improve M&V accuracy compared to traditional, system-specific methods in complex industrial settings?
- RQ4Does the methodology maintain robustness and reliability under real-world conditions, such as changing static factors and incomplete data?
- RQ5Can the methodology reduce the need for additional metering infrastructure while still delivering acceptable uncertainty levels for policy and investment purposes?
Key findings
- The optimal baseline model was a k-Nearest Neighbors (k-NN) regression model trained on hourly data, achieving a cross-validated root mean square error (CV(RMSE)) of 11.23%.
- Total energy savings over the 222-day reporting period were estimated at 604,527 kWh, with a 68% confidence interval ranging from 256,485 kWh to 952,568 kWh.
- The range of savings across all 20 models highlighted that model performance in cross-validation did not always correlate with savings estimates, as models with higher reported savings were favored under uncertainty thresholds.
- The adjusted R² value for the best-performing model (15-minute frequency) was 0.663, indicating a moderate but statistically significant relationship between predictors and chilled water electrical load.
- The methodology successfully enabled M&V in a real industrial facility with suboptimal conditions—limited metering, data quality issues, and dynamic factors—demonstrating its robustness in challenging environments.
- The approach significantly reduces the need for additional metering infrastructure, lowering resource and cost barriers to accurate M&V in industrial energy projects.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.