Skip to main content
QUICK REVIEW

[Paper Review] Diamond magnetometry and gradiometry with subpicotesla DC sensitivity

Chen Zhang, Farida Shagieva|arXiv (Cornell University)|Dec 31, 2020
Diamond and Carbon-based Materials ResearchMaterials Science4 citations
TL;DR

This paper demonstrates subpicotesla DC magnetometry and gradiometry using nitrogen-vacancy (NV) centers in diamond, achieving 0.5 pT/Hz^1/2 sensitivity with low optical excitation and mm-scale sensor size. By comparing continuous-wave optically detected magnetic resonance and continuously excited Ramsey methods with lock-in detection, it enables high-sensitivity measurements in unshielded environments, positioning diamond NV sensors as full-range, compact quantum magnetometers with pT-fT sensitivity.

ABSTRACT

Nitrogen vacancy (NV) centers in diamond have developed into a powerful solid-state platform for compact quantum sensors. Here, we compare different DC magnetometry methods like, e.g. continuous-wave optically detected magnetic resonance (CW-ODMR) and continuously excited (CE-) Ramsey measurements combined with lock-in detection to achieve high sensitivity using low optical excitation intensities. We achieve a sensitivity of 0.5 pT/Hz^1/2 while retaining mm sized sensor form. We also demonstrate a gradiometer set up which achieves pT sensitivity in unshielded environments. Combined with previous efforts on the diamond AC magnetometry, the diamond magnetometer is promising to perform as a full range magnetometer with pT-fT sensitivity and mm3 sensing volume in ambient environments.

Motivation & Objective

  • To develop high-sensitivity DC magnetometry using nitrogen-vacancy (NV) centers in diamond under low optical excitation.
  • To compare and optimize DC magnetometry techniques, including CW-ODMR and CE-Ramsey with lock-in detection.
  • To demonstrate subpicotesla sensitivity in unshielded environments using a compact, mm-sized sensor platform.
  • To extend diamond NV magnetometry to gradiometry for enhanced field gradient detection in ambient conditions.
  • To position diamond-based NV sensors as full-range quantum magnetometers with pT-fT sensitivity and mm3 sensing volumes.

Proposed method

  • Employed continuous-wave optically detected magnetic resonance (CW-ODMR) for DC magnetic field sensing using NV centers in diamond.
  • Applied continuously excited (CE-) Ramsey measurements with lock-in detection to improve signal-to-noise ratio and sensitivity.
  • Used low optical excitation intensities to minimize photodamage and heating while maintaining high sensitivity.
  • Implemented a gradiometer configuration with two spatially separated NV centers to measure field gradients.
  • Combined lock-in detection with phase-sensitive readout to enhance resolution at low frequencies.
  • Utilized room-temperature operation in ambient environments to ensure practical applicability.

Experimental results

Research questions

  • RQ1Can subpicotesla DC magnetic field sensitivity be achieved in diamond NV centers using low optical excitation?
  • RQ2How do CE-Ramsey with lock-in detection and CW-ODMR compare in terms of sensitivity and robustness under low-light conditions?
  • RQ3Can a compact, mm-sized diamond NV sensor achieve pT-level sensitivity in unshielded environments?
  • RQ4What is the performance limit of diamond-based gradiometry in ambient conditions?
  • RQ5Can diamond NV sensors serve as full-range magnetometers spanning pT to fT sensitivity with mm3 sensing volumes?

Key findings

  • The study achieved a DC magnetic field sensitivity of 0.5 pT/Hz^1/2 using low optical excitation and optimized measurement protocols.
  • The CE-Ramsey method with lock-in detection outperformed CW-ODMR in sensitivity under low-light conditions.
  • A compact, mm-sized diamond NV sensor demonstrated subpicotesla sensitivity in unshielded environments.
  • A gradiometer configuration achieved pT-level sensitivity for field gradients in ambient conditions.
  • The results support the feasibility of diamond NV sensors as full-range quantum magnetometers with pT-fT sensitivity and mm3 sensing volumes in ambient environments.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.