Skip to main content
QUICK REVIEW

[Paper Review] Dilated-UNet: A Fast and Accurate Medical Image Segmentation Approach using a Dilated Transformer and U-Net Architecture

Davoud Saadati, Omid Nejati Manzari|arXiv (Cornell University)|Apr 22, 2023
Advanced Neural Network ApplicationsComputer Science17 citations
TL;DR

Dilated-UNet combines a Dilated Transformer block with a U-Net style encoder–decoder to achieve fast and accurate 2D medical image segmentation, outperforming several state-of-the-art models on Synapse and ISIC datasets.

ABSTRACT

Medical image segmentation is crucial for the development of computer-aided diagnostic and therapeutic systems, but still faces numerous difficulties. In recent years, the commonly used encoder-decoder architecture based on CNNs has been applied effectively in medical image segmentation, but has limitations in terms of learning global context and spatial relationships. Some researchers have attempted to incorporate transformers into both the decoder and encoder components, with promising results, but this approach still requires further improvement due to its high computational complexity. This paper introduces Dilated-UNet, which combines a Dilated Transformer block with the U-Net architecture for accurate and fast medical image segmentation. Image patches are transformed into tokens and fed into the U-shaped encoder-decoder architecture, with skip-connections for local-global semantic feature learning. The encoder uses a hierarchical Dilated Transformer with a combination of Neighborhood Attention and Dilated Neighborhood Attention Transformer to extract local and sparse global attention. The results of our experiments show that Dilated-UNet outperforms other models on several challenging medical image segmentation datasets, such as ISIC and Synapse.

Motivation & Objective

  • Motivate improved medical image segmentation by enriching CNN-based encoders with global context learning.
  • Propose a Dilated Transformer-based encoder–decoder architecture that preserves local detail via Neighborhood Attention and global context via Dilated Neighborhood Attention.
  • Design a U-Net-like structure with skip connections and a patch expanding decoder to restore resolution without traditional convolutions.
  • Demonstrate robustness and generalization on skin lesion (ISIC) and multi-organ (Synapse) segmentation datasets.

Proposed method

  • Introduce the Dilated-UNet architecture built on a four-part U-shaped design (encoder, bottleneck, decoder, skip connections) using Dilated Transformer blocks.
  • Use DiNA (dilated neighborhood attention) and NA (neighborhood attention) within successive Transformer blocks to capture sparse global and local relations.
  • Maintain feature dimension and resolution in the encoder with patch merging that downsamples token count while doubling feature channels; a patch expanding decoder upsamples with a linear layer to preserve information.
  • Employ a skip-connection module that concatenates encoder and decoder features and aligns dimensions with a linear layer to maintain consistency.
  • Adopt a two-block bottleneck to mitigate training convergence issues common in deep Transformers, keeping resolution and channels unchanged.
  • Evaluate with 224x224 and 384x384 inputs, showing a trade-off between accuracy and compute, and perform ablations on skip connections and input size.

Experimental results

Research questions

  • RQ1How does integrating a Dilated Transformer block with NA and DiNA mechanisms affect local detail and global context in medical image segmentation?
  • RQ2What is the impact of multiple skip connections on segmentation accuracy across organs of varying sizes?
  • RQ3Does the patch expansion decoder effectively replace traditional upsampling/convolution for restoring spatial resolution in a Transformer-based U-Net?
  • RQ4What is the effect of input resolution and model scale on performance and efficiency across ISIC and Synapse datasets.

Key findings

  • On Synapse multi-organ segmentation, Dilated-Unet achieves an average DSC of 82.43 and HD of 17.46, outperforming several CNN-, Transformer-, and hybrid-based models.
  • On ISIC2018 skin lesion segmentation, Dilated-Unet attains 0.9147 DSC (and 0.9129 HD-based metric in the table), surpassing SOTA methods like Swin-Unet and TransNorm.
  • Increasing the number of skip connections from 0 to 3 substantially improves organ-wise DSC and reduces HD, with 3 skips yielding the best overall results.
  • Larger input size (384x384) improves DSC and HD over 224x224 but increases computational cost, leading to a practical choice of 224x224 for efficiency.
  • Model size ablations show that Dilated-Unet-tiny/small achieve strong performance with substantially fewer parameters than some competing methods.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.