Skip to main content
QUICK REVIEW

[Paper Review] Direct dark matter search by annual modulation in XMASS-I

XMASS Collaboration, K. Abe|arXiv (Cornell University)|Nov 16, 2015
Dark Matter and Cosmic PhenomenaPhysics and Astronomy1 references10 citations
TL;DR

This study presents the first extensive annual modulation search in a single-phase liquid xenon detector, XMASS-I, using 359.2 live days of data and 832 kg of exposure. It sets a 90% confidence level upper limit of 4.3 × 10⁻⁴¹ cm² on the WIMP-nucleon cross section at 8 GeV/c², excluding most of the DAMA/LIBRA-allowed region for WIMPs and providing stringent constraints on electron/gamma-induced modulation models down to 1.1 keV ee energy threshold.

ABSTRACT

A search for dark matter was conducted by looking for an annual modulation signal due to the Earth's rotation around the Sun using XMASS, a single phase liquid xenon detector. The data used for this analysis was 359.2 live days times 832 kg of exposure accumulated between November 2013 and March 2015. When we assume Weakly Interacting Massive Particle (WIMP) dark matter elastically scattering on the target nuclei, the exclusion upper limit of the WIMP-nucleon cross section 4.3$ imes$10$^{-41}$cm$^2$ at 8 GeV/c$^2$ was obtained and we exclude almost all the DAMA/LIBRA allowed region in the 6 to 16 GeV/c$^2$ range at $\sim$10$^{-40}$cm$^2$. The result of a simple modulation analysis, without assuming any specific dark matter model but including electron/$γ$ events, showed a slight negative amplitude. The $p$-values obtained with two independent analyses are 0.014 and 0.068 for null hypothesis, respectively. we obtained 90\% C.L. upper bounds that can be used to test various models. This is the first extensive annual modulation search probing this region with an exposure comparable to DAMA/LIBRA.

Motivation & Objective

  • To search for annual modulation in dark matter detection signals using the XMASS-I single-phase liquid xenon detector.
  • To test the DAMA/LIBRA signal hypothesis by probing low-energy electron and gamma recoils, not just nuclear recoils.
  • To provide model-independent constraints on annual modulation amplitudes across a broad energy range down to 1.1 keV ee.
  • To improve sensitivity to light WIMPs and alternative dark matter candidates by leveraging high exposure and low energy threshold.
  • To compare results with DAMA/LIBRA and XENON100 to assess consistency with electron-scattering or light dark matter models.

Proposed method

  • Utilized 359.2 live days of data with 832 kg of liquid xenon exposure from November 2013 to March 2015.
  • Applied a model-independent modulation analysis using two independent methods: 'pull term' and covariance matrix, both assuming a 1-year period and fixed phase at 152.5 days (early June).
  • Fitted event rates using the equation: $ R_{i,j}^{ ext{ex}} = \int_{t_j - \frac{1}{2}\Delta t_j}^{t_j + \frac{1}{2}\Delta t_j} \left( C_i + A_i \cos 2\pi \frac{(t - t_0)}{T} \right) dt $, where $ C_i $ is unmodulated rate and $ A_i $ is modulation amplitude.
  • Calculated energy-dependent efficiency using gamma-ray Monte Carlo simulations with a flat energy spectrum in the sensitive volume.
  • Determined 90% confidence level upper limits on positive and negative modulation amplitudes by integrating Gaussian distributions from zero to the upper limit.
  • Used energy resolution of 36% (1.0 keV ee) and 19% (5.0 keV ee) from gamma calibration and simulation to correct for resolution effects.

Experimental results

Research questions

  • RQ1Can an annual modulation signal from dark matter be detected in XMASS-I using a single-phase liquid xenon detector with low energy threshold?
  • RQ2To what extent do the XMASS-I results exclude the DAMA/LIBRA-observed modulation as arising from WIMP-nucleon scattering?
  • RQ3What are the constraints on electron or gamma-induced modulation signals at energies below 4 keV ee, where other experiments are less sensitive?
  • RQ4How do the results compare with XENON100 and DAMA/LIBRA in terms of modulation amplitude limits across different energy bins?
  • RQ5Can the model-independent analysis distinguish between positive and negative modulation amplitudes at the 1.1–7.6 keV ee threshold?

Key findings

  • The model-independent analysis found a slight negative modulation amplitude below 4 keV ee, with p-values of 0.014 (2.5σ) and 0.068 (1.8σ) for the null hypothesis using two independent methods.
  • The 90% confidence level upper limit on the positive (negative) modulation amplitude is $ 2.1 \times 10^{-2} $ events/day/kg/keV ee in the 1.1–1.6 keV ee energy bin.
  • In the 2.0–6.0 keV ee range, the upper limit on the amplitude is $ (1.7 - 3.7) \times 10^{-3} $ events/day/kg/keV ee, which is more stringent than XENON100’s $ 3.7 \times 10^{-3} $ limit.
  • For WIMP-nucleon scattering, the exclusion upper limit on the cross section is $ 4.3 \times 10^{-41} \, \text{cm}^2 $ at 8 GeV/c², excluding almost all of the DAMA/LIBRA-allowed region for WIMP masses between 6 and 16 GeV/c².
  • The analysis achieved a lower energy threshold (1.1 keV ee) than both DAMA/LIBRA and XENON100, enabling sensitivity to light dark matter and electron-scattering models.
  • The results are robust across two independent fitting methods and are consistent with no significant modulation, placing strong constraints on alternative dark matter models involving electron or photon recoils.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint