Skip to main content
QUICK REVIEW

[Paper Review] Direct Dark Matter search with the XENON program

P. Beltrame|arXiv (Cornell University)|May 13, 2013
Dark Matter and Cosmic PhenomenaPhysics and Astronomy4 references11 citations
TL;DR

This paper presents the latest results from the XENON100 experiment, a dual-phase time-projection chamber at LNGS that achieved the most stringent limits to date on spin-independent WIMP-nucleon cross sections—down to $2 \times 10^{-45}\ \text{cm}^2$ at 55 GeV/$c^2$—and spin-dependent WIMP-neutron cross sections—down to $3.5 \times 10^{-40}\ \text{cm}^2$ at 45 GeV/$c^2$. It also details the design and physics goals of XENON1T, a next-generation 3-ton liquid xenon detector expected to probe spin-independent cross sections down to $2 \times 10^{-47}\ \text{cm}^2$ for 50 GeV/$c^2$ WIMPs.

ABSTRACT

We present the most recent results from XENON100, the current phase of the XENON dark matter search program. XENON100 is a dual phase time-projection chamber operated at the Laboratori Nazionali del Gran Sasso (LNGS) whose ultra-low electromagnetic background, about 5 x 10^-3 events/(kg x day x keV), allowed to set the most stringent limit to date, excluding WIMP-nucleon spin-independent interaction down to cross-sections of 2 x 10^-45 cm^2 for a 55 GeV/c^2 mass at 90% confidence level and 3.5 x10^-40 for 45 GeV/c^2 in the spin-dependent interaction with neutrons. We also introduce the status and physics goal of XENON1T, the next phase of the program, which will be able to achieve sensitivity down to 2 x 10^-47 cm^2 for a WIMP of 50 GeV/c^2.

Motivation & Objective

  • To set the most stringent direct limits on spin-independent and spin-dependent WIMP-nucleon interactions using XENON100 data.
  • To validate the detector response model for nuclear recoils using $^{241}$AmBe neutron calibration data.
  • To demonstrate the feasibility and sensitivity of XENON1T, a 3-ton liquid xenon TPC, for probing the remaining parameter space of WIMP dark matter.
  • To improve background suppression through ultra-low electromagnetic backgrounds and enhanced signal discrimination via $S2/S1$ ratio.
  • To achieve sub-keV energy threshold and high fiducial volume for enhanced sensitivity to low-mass WIMPs.

Proposed method

  • Utilizes a dual-phase time-projection chamber (TPC) with liquid xenon (62 kg) and a gaseous xenon scintillation veto (99 kg) to detect WIMP nuclear recoils.
  • Employs 242 radio-pure photomultiplier tubes (PMTs) to detect prompt scintillation (S1) and proportional scintillation (S2) signals from ionization electrons.
  • Applies $S2/S1$ ratio discrimination to separate electronic recoils (ERs, background) from nuclear recoils (NRs, signal), using quenching factors $\mathcal{L}_{\text{eff}}$ and $\mathcal{Q}_{y}$.
  • Performs energy calibration using $^{60}$Co and $^{232}$Th sources for electron-equivalent energy scale (keVee), and $^{241}$AmBe neutrons for nuclear recoil calibration (keVnr).
  • Uses Profile Likelihood statistical method to set 90% confidence level upper limits on WIMP cross sections, with blind analysis and fiducial volume selection (34 kg).
  • Optimizes detector response models by fitting Monte Carlo simulations to $S1$ and $S2$ spectra, achieving 2% agreement in discrimination parameter space.

Experimental results

Research questions

  • RQ1What are the most stringent limits on spin-independent WIMP-nucleon cross sections achievable with XENON100?
  • RQ2How does the $S2/S1$ ratio discrimination perform for nuclear recoils in liquid xenon, and what is the resulting energy scale accuracy?
  • RQ3What improvements in background suppression and energy threshold are required to reach the sensitivity goal of XENON1T?
  • RQ4To what extent does the inclusion of chiral effective field theory currents improve the prediction of nuclear matrix elements for WIMP interactions?
  • RQ5How well does the combined $S1$ and $S2$ response model reproduce the observed data in discrimination space?

Key findings

  • XENON100 set the most stringent limit on spin-independent WIMP-nucleon cross sections at $2 \times 10^{-45}\ \text{cm}^2$ for a 55 GeV/$c^2$ WIMP at 90% confidence level.
  • The experiment achieved a background level of $5 \times 10^{-3}$ events/(kg·day·keV), with $^{85}$Kr concentration reduced to $19 \pm 4$ ppt, significantly lowering intrinsic background.
  • XENON100 excluded spin-dependent WIMP-neutron cross sections down to $3.5 \times 10^{-40}\ \text{cm}^2$ at 45 GeV/$c^2$, setting the tightest constraints to date.
  • The optimized $\mathcal{Q}_{y}$ for ionization yield showed no low-energy enhancement, differing from some direct measurements, and was consistent with indirect estimates.
  • The combined $S1$ and $S2$ model achieved excellent agreement (within 2%) with data in the $S2/S1$ discrimination plane for both signal and background distributions.
  • XENON1T is projected to achieve a sensitivity of $2 \times 10^{-47}\ \text{cm}^2$ for a 50 GeV/$c^2$ WIMP, with a background level of $5 \times 10^{-5}$ DRU, enabling two-year data taking with less than one expected background event in 8–45 keVnr.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.