[Paper Review] Disease Detection in Weakly Annotated Volumetric Medical Images using a Convolutional LSTM Network
This paper proposes a 3D convolutional LSTM network that detects emphysema in low-dose CT scans using only binary disease labels, avoiding the need for precise lesion annotations. By processing volumetric data as a sequence of 2D slices, the model captures spatial relationships across slices and achieves an AUC of 0.83, outperforming 2D MIL-based CNNs (AUC 0.69–0.76) and a 3D CNN (AUC 0.77).
We explore a solution for learning disease signatures from weakly, yet easily obtainable, annotated volumetric medical imaging data by analyzing 3D volumes as a sequence of 2D images. We demonstrate the performance of our solution in the detection of emphysema in lung cancer screening low-dose CT images. Our approach utilizes convolutional long short-term memory (LSTM) to "scan" sequentially through an imaging volume for the presence of disease in a portion of scanned region. This framework allowed effective learning given only volumetric images and binary disease labels, thus enabling training from a large dataset of 6,631 un-annotated image volumes from 4,486 patients. When evaluated in a testing set of 2,163 volumes from 2,163 patients, our model distinguished emphysema with area under the receiver operating characteristic curve (AUC) of .83. This approach was found to outperform 2D convolutional neural networks (CNN) implemented with various multiple-instance learning schemes (AUC=0.69-0.76) and a 3D CNN (AUC=.77).
Motivation & Objective
- To develop a deep learning framework for disease detection in volumetric medical images that requires only binary diagnostic labels, avoiding costly manual segmentation.
- To address the challenge of detecting localized diseases like emphysema in 3D CT scans where lesions may appear in only a fraction of the volume.
- To overcome limitations of multiple instance learning (MIL) by preserving spatial relationships between slices through sequential processing.
- To enable training on large-scale, weakly annotated datasets by leveraging radiology report-derived labels without requiring expert-annotated regions.
- To demonstrate the feasibility of retraining and fine-tuning models across different clinical sites using easily accessible binary labels.
Proposed method
- The model processes 3D CT volumes as a sequence of 2D axial slices, applying convolutional layers to each slice followed by a convolutional LSTM (Conv-LSTM) to model spatial-temporal dependencies across slices.
- The architecture uses four Conv-LSTM units with shared filter counts: two ascending (32 filters) and two descending (32 filters), followed by two ascending (64 filters) and two descending (64 filters), enabling bidirectional feature learning.
- Each Conv-LSTM unit processes slices in order (ascending or descending), maintaining hidden states that capture disease patterns across multiple slices, with final features summarizing the entire volume.
- A final fully connected layer with sigmoid activation outputs the probability of emphysema, trained end-to-end using binary cross-entropy loss.
- The model is trained on 6,631 un-annotated CT volumes from 4,486 patients, with 75% used for training, 25% for validation and hyperparameter tuning.
- Performance is compared against 2D MIL-based CNNs using max, mean, and product pooling strategies, and a 3D CNN with equivalent parameter count for fairness.
Experimental results
Research questions
- RQ1Can a Conv-LSTM model effectively detect emphysema in volumetric CT scans when only binary disease labels are available?
- RQ2Does sequential processing of 2D slices via Conv-LSTM preserve spatial relationships between slices better than MIL-based pooling strategies?
- RQ3How does the performance of a Conv-LSTM model compare to 2D MIL-CNNs and 3D CNNs in detecting emphysema using weakly annotated data?
- RQ4Can the model generalize across patients and detect disease even when lesions are localized to only a small portion of the lung volume?
- RQ5To what extent can radiology report-derived binary labels be used to train high-performing models without manual segmentation?
Key findings
- The Conv-LSTM model achieved an area under the ROC curve (AUC) of 0.83 in detecting emphysema on an independent test set of 2,163 CT volumes.
- The model significantly outperformed 2D MIL-based CNNs, which achieved AUCs of 0.69 (max pooling), 0.70 (mean pooling), and 0.76 (product pooling).
- The Conv-LSTM also outperformed a 3D CNN with a similar parameter count, which achieved an AUC of 0.77.
- At the Youden index optimal threshold, the model achieved 77% sensitivity and 74% specificity, indicating strong balance between detecting true positives and minimizing false positives.
- The model’s performance was robust across different pooling strategies and demonstrated the ability to learn disease patterns even when emphysema was localized to only a subset of slices.
- The framework enables training on large-scale datasets using only binary labels from radiology reports, significantly expanding the pool of usable data for model development.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.