[Paper Review] Distribution Calibration for Regression
This paper introduces distribution calibration for regression, proposing a post-hoc method using multi-output Gaussian Processes with a novel Beta link function to calibrate uncertainty estimates. The GP-Beta approach improves both distribution-level and quantile-level calibration across diverse regression models, outperforming existing methods like isotonic regression in real-world and synthetic datasets.
We are concerned with obtaining well-calibrated output distributions from regression models. Such distributions allow us to quantify the uncertainty that the model has regarding the predicted target value. We introduce the novel concept of distribution calibration, and demonstrate its advantages over the existing definition of quantile calibration. We further propose a post-hoc approach to improving the predictions from previously trained regression models, using multi-output Gaussian Processes with a novel Beta link function. The proposed method is experimentally verified on a set of common regression models and shows improvements for both distribution-level and quantile-level calibration.
Motivation & Objective
- To address the lack of well-calibrated uncertainty estimates in regression models, especially for complex or pre-trained models like deep neural networks.
- To define and formalize distribution-level calibration as a stronger, more informative form of calibration than traditional quantile calibration.
- To develop a scalable, post-hoc calibration method that improves uncertainty estimation without retraining the base regression model.
- To demonstrate that distribution calibration naturally implies quantile calibration, offering a more coherent uncertainty representation.
- To provide a flexible, probabilistic framework for calibrating conditional density estimates using Gaussian processes and a novel link function.
Proposed method
- Proposes a multi-output Gaussian Process model that learns calibration parameters (mean and variance) for each input instance, enabling instance-specific calibration.
- Introduces a novel Beta link function to map model outputs to calibrated predictive distributions, ensuring proper probabilistic constraints.
- Uses stochastic variational inference with inducing points to scale the method to large datasets, maintaining computational efficiency.
- Calibrates the predictive CDF by matching empirical quantiles through a learned calibration map that varies per input, unlike isotonic regression's global map.
- Employs a trapezoidal approximation over 4096 points per instance to estimate expected values and compute NLL for evaluation.
- Optimizes the model using ADAM with 64 Monte Carlo samples per batch, training on a 75/25 split of the data.
Experimental results
Research questions
- RQ1Can distribution-level calibration be defined and formalized in regression, and does it imply better uncertainty quantification than quantile calibration?
- RQ2Can a post-hoc method improve calibration of pre-trained regression models without retraining?
- RQ3Does the proposed GP-Beta method outperform existing post-hoc calibration techniques like isotonic regression in both distribution-level and quantile-level calibration?
- RQ4How does the method scale to large datasets, and what impact do the number of inducing points have on performance?
- RQ5Is the proposed method robust across diverse regression models and real-world datasets with varying data distributions?
Key findings
- The GP-Beta method consistently improves calibration across all evaluated metrics, especially in NLL, which is the most faithful measure for distribution calibration.
- For most datasets, GP-Beta outperforms isotonic regression in both distribution-level and quantile-level calibration, with the largest gains observed in synthetic data requiring local calibration.
- The method shows strong performance even with 8 inducing points, and increasing to 64 improves results on larger datasets like Airfoil (n=1503), suggesting scalability can be enhanced with more inducing points.
- On the Energy dataset (n=19,735), isotonic regression showed unexpectedly low NLL due to a step change near zero in the target distribution, highlighting the risk of global calibration methods.
- GP-Beta achieved the best NLL in nearly all cases, regardless of the number of inducing points, demonstrating its robustness and superiority in distribution calibration.
- The method successfully learns instance-specific calibration maps, as visualized in Figure 2, unlike isotonic regression, which applies a single global map to all inputs.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.