Hadrien Bertrand, Mohammad Hashir|arXiv (Cornell University)|Apr 17, 2019
COVID-19 diagnosis using AIMedicine8 references10 citations
TL;DR

This study evaluates whether lateral chest X-ray views improve automated disease prediction using a DenseNet model on the PadChest dataset. It finds that lateral views boost performance for 8 out of 56 labels—particularly pleural effusion and diaphragm abnormalities—while offering comparable performance to PA views for 21 labels, suggesting targeted utility of lateral views in multi-view deep learning for radiology.

ABSTRACT

Most convolutional neural networks in chest radiology use only the frontal posteroanterior (PA) view to make a prediction. However the lateral view is known to help the diagnosis of certain diseases and conditions. The recently released PadChest dataset contains paired PA and lateral views, allowing us to study for which diseases and conditions the performance of a neural network improves when provided a lateral x-ray view as opposed to a frontal posteroanterior (PA) view. Using a simple DenseNet model, we find that using the lateral view increases the AUC of 8 of the 56 labels in our data and achieves the same performance as the PA view for 21 of the labels. We find that using the PA and lateral views jointly doesn't trivially lead to an increase in performance but suggest further investigation.

Motivation & Objective

  • To investigate whether incorporating lateral chest X-ray views improves automated disease classification compared to using only posteroanterior (PA) views.
  • To assess the relative contribution of lateral views across a broad spectrum of 56 radiological diagnoses in a large, multi-view dataset.
  • To evaluate whether combining PA and lateral views via simple fusion strategies leads to consistent performance gains.
  • To identify specific pathologies for which lateral views provide clinically meaningful diagnostic information beyond PA views.
  • To validate the reliability of weakly supervised labels in the PadChest dataset for downstream deep learning tasks.

Proposed method

  • Trained a single DenseNet model on only PA views and another on only lateral views, using a 60-20-20 training-validation-test split.
  • Applied class-weighted binary cross-entropy loss with frequency-based weights clamped between 1 and 5 to address class imbalance.
  • Used data augmentation via center cropping and pixel value scaling to [-1, 1] for input normalization.
  • Selected the best-performing model per label based on validation AUC, with early stopping and 5 random weight initializations per model.
  • Mapped 194 original labels to 56 top-level labels to increase sample size and improve training stability.
  • Evaluated performance using area under the ROC curve (AUC) on the test set, with results visualized per label across multiple random seeds.

Experimental results

Research questions

  • RQ1For how many of the 56 radiological labels does the lateral view improve model performance compared to the PA view alone?
  • RQ2Are there specific pathologies for which the lateral view provides significantly more diagnostic information than the PA view?
  • RQ3Does combining PA and lateral views through simple early or late fusion strategies lead to consistent performance gains across labels?
  • RQ4How does model variance across random seeds affect the reliability of performance comparisons between PA and lateral views?
  • RQ5To what extent do weakly supervised labels in PadChest affect the validity of the observed performance trends?

Key findings

  • The lateral view improved model performance (AUC) over the PA view for 8 out of 56 labels, including pleural effusion, artificial heart valve, and hemidiaphragm elevation.
  • For 21 labels, the lateral view achieved performance comparable to the PA view, with differences in AUC below the standard deviation across multiple random seeds.
  • The average weighted AUC across all 56 labels was 0.79, indicating strong baseline performance despite the use of a simple DenseNet architecture.
  • Combining both views using simple fusion strategies did not yield consistent improvements and showed high variance across random seeds, suggesting non-trivial challenges in multi-view integration.
  • The results suggest that lateral views are not universally beneficial but are particularly informative for pathologies involving the heart, diaphragm, and posterior lung structures.
  • The high variance in performance for some labels indicates the need for further validation on larger, more diverse datasets such as MIMIC-CXR and CheXpert.