Skip to main content
QUICK REVIEW

[Paper Review] Dual-Decoder Consistency via Pseudo-Labels Guided Data Augmentation for Semi-Supervised Medical Image Segmentation

Yuanbin Chen, Tao Wang|arXiv (Cornell University)|Aug 31, 2023
Image Retrieval and Classification TechniquesComputer Science3 citations
TL;DR

This paper proposes DCPA, a semi-supervised medical image segmentation method that uses a dual-decoder architecture with consistency regularization and pseudo-label guided data augmentation to improve performance with limited labeled data. By generating pseudo-labels from a teacher network and augmenting training data using mixup-like strategies, DCPA achieves state-of-the-art results, especially with only 5% labeled data across three benchmark datasets.

ABSTRACT

While supervised learning has achieved remarkable success, obtaining large-scale labeled datasets in biomedical imaging is often impractical due to high costs and the time-consuming annotations required from radiologists. Semi-supervised learning emerges as an effective strategy to overcome this limitation by leveraging useful information from unlabeled datasets. In this paper, we present a novel semi-supervised learning method, Dual-Decoder Consistency via Pseudo-Labels Guided Data Augmentation (DCPA), for medical image segmentation. We devise a consistency regularization to promote consistent representations during the training process. Specifically, we use distinct decoders for student and teacher networks while maintain the same encoder. Moreover, to learn from unlabeled data, we create pseudo-labels generated by the teacher networks and augment the training data with the pseudo-labels. Both techniques contribute to enhancing the performance of the proposed method. The method is evaluated on three representative medical image segmentation datasets. Comprehensive comparisons with state-of-the-art semi-supervised medical image segmentation methods were conducted under typical scenarios, utilizing 10% and 20% labeled data, as well as in the extreme scenario of only 5% labeled data. The experimental results consistently demonstrate the superior performance of our method compared to other methods across the three semi-supervised settings. The source code is publicly available at https://github.com/BinYCn/DCPA.git.

Motivation & Objective

  • To address the challenge of limited labeled medical image data, which is costly and time-consuming to obtain from radiologists.
  • To improve generalization and robustness in semi-supervised medical image segmentation by effectively leveraging unlabeled data.
  • To mitigate performance degradation caused by data imbalance and noisy pseudo-labels in low-data regimes.
  • To enhance model consistency and segmentation accuracy through a novel dual-decoder architecture and guided data augmentation.
  • To establish a robust framework that performs strongly even under extreme label scarcity, such as 5% labeled data.

Proposed method

  • The method employs a mean-teacher framework with a shared encoder and two distinct decoders for student and teacher networks.
  • Pseudo-labels are generated by the teacher network on unlabeled data and used to guide data augmentation by mixing labeled and unlabeled samples.
  • A mixup-style data augmentation strategy combines labeled and pseudo-labeled samples using a weighted average, enhancing training diversity.
  • Consistency regularization is applied between the two decoders to enforce agreement on predictions, improving model robustness.
  • A sharpening function with a temperature coefficient is applied to refine pseudo-label confidence and improve boundary clarity.
  • The training process uses consistency loss between decoders and optimizes both student and teacher networks end-to-end.

Experimental results

Research questions

  • RQ1Can a dual-decoder architecture with consistency regularization improve semi-supervised medical image segmentation under low-label regimes?
  • RQ2How effective is pseudo-label guided data augmentation in enhancing model generalization when labeled data is scarce?
  • RQ3What is the optimal number of weak augmentations and sharpening temperature for robust performance across datasets?
  • RQ4How does the method perform under extreme label scarcity, such as 5% labeled data?
  • RQ5Can the proposed method outperform existing state-of-the-art semi-supervised methods in diverse medical image segmentation scenarios?

Key findings

  • DCPA outperforms six state-of-the-art methods on three public medical image segmentation datasets under all evaluation settings, including 5% labeled data.
  • With only 5% labeled data, DCPA achieved a Dice score of 83.05% on the Pancreas-CT dataset, demonstrating strong performance in extreme low-data regimes.
  • The method achieved peak performance with K=2 weak augmentations, showing sensitivity to augmentation count under low-label conditions.
  • A temperature coefficient of T=0.1 in the sharpening function yielded the best results, balancing confidence and boundary clarity.
  • The dual-decoder consistency loss significantly improved performance, especially when combined with pseudo-label guided data augmentation.
  • The method demonstrated robustness across different datasets and label proportions, with consistent gains in Dice score over baselines.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.