TL;DR

This study investigates dynamic Structure-Soil-Structure Interaction (SSSI) in nuclear power plants using high-fidelity 3D finite element models in the Real-ESSI Simulator, revealing that nonlinear soil and interface behavior can transform detrimental rotational coupling into beneficial out-of-phase horizontal interaction, reducing spectral accelerations in critical reactor components by up to 55% near the auxiliary building's resonant frequency.

ABSTRACT

The paper explores the linear and nonlinear dynamic interaction between the reactor and the auxiliary buildings of a Nuclear Power Plant, aiming to evaluate the effect of the auxiliary building on the seismic response of crucial components inside the reactor building. Based on realistic geometrical assumptions, high-fidelity 3D finite element (FE) models of increasing sophistication are created in the Real-ESSI Simulator. Starting with elastic soil conditions and assuming tied soil-foundation interfaces, it is shown that the rocking vibration mode of the soil-reactor building system is amplified by the presence of the auxiliary building through a detrimental out-of-phase rotational interaction mechanism. Adding nonlinear interfaces, which allow for soil foundation detachment during seismic shaking, introduces higher excitation frequencies (above 10 Hz) in the foundation of the reactor building, leading to amplification effects in the resonant vibration response of the biological shield wall inside the reactor building. A small amount of sliding at the soil-foundation interface of the auxiliary building slightly decreases its response, thus reducing its aforementioned negative effects on the reactor building. When soil nonlinearity is accounted for, the rocking vibration mode of the soil-reactor building system almost vanishes, thanks to the strongly nonlinear response of the underlying soil. This leads to a beneficial out-of-phase horizontal interaction mechanism between the two buildings, reducing the spectral accelerations at critical points inside the reactor building by up to 55% for frequencies close to the resonant one of the auxiliary building. This implies that the neighboring buildings could offer mutual seismic protection to each other, in a similar way to the recently emerged seismic resonant metamaterials, provided that they are properly tuned during the design phase.

Motivation & Objective

  • To evaluate the impact of auxiliary buildings on the seismic response of reactor buildings via dynamic SSSI.
  • To assess the influence of soil and interface nonlinearities on SSSI mechanisms in nuclear power plants.
  • To investigate whether neighboring structures can provide mutual seismic protection, akin to seismic resonant metamaterials.
  • To develop and apply high-fidelity 3D finite element models with realistic soil profiles and nonlinear interfaces.

Proposed method

  • High-fidelity 3D finite element models of reactor and auxiliary buildings were developed using the Real-ESSI Simulator.
  • The Domain Reduction Method (DRM) was employed to inject SH-wave accelerograms into the soil domain.
  • Elastic and nonlinear soil behavior was modeled using a cyclic elastoplastic constitutive model for clays.
  • Tied and nonlinear soil-foundation interfaces were simulated, including gapping and limited sliding.
  • Progressively complex models were analyzed: first elastic soil with tied interfaces, then nonlinear interfaces, and finally nonlinear soil with nonlinear interfaces.
  • Spectral accelerations at critical points in the reactor building were evaluated across a range of frequencies.

Experimental results

Research questions

  • RQ1How does the presence of an auxiliary building affect the seismic response of a reactor building via SSSI?
  • RQ2What is the role of soil and interface nonlinearities in altering the dynamic interaction mechanism between adjacent nuclear buildings?
  • RQ3Can SSSI between adjacent structures lead to beneficial seismic protection, similar to resonant metamaterials?
  • RQ4How do nonlinear interfaces influence the development of higher-frequency excitations in the reactor building foundation?
  • RQ5To what extent can the dynamic characteristics of neighboring buildings be tuned to reduce seismic demand on critical components?

Key findings

  • The presence of the auxiliary building amplifies spectral accelerations in the reactor building due to a detrimental out-of-phase rotational interaction mechanism when soil and interfaces are elastic and tied.
  • Nonlinear interfaces introduce higher-frequency excitations (>10 Hz) in the reactor building foundation, increasing resonant response of the biological shield wall and reactor vessel.
  • Limited sliding at the auxiliary building's interface slightly reduces its response, thereby diminishing the negative impact on the reactor building.
  • Nonlinear soil behavior suppresses the rocking mode of the reactor building, transforming the interaction into a beneficial out-of-phase horizontal mechanism.
  • For frequencies near the auxiliary building’s resonance, spectral accelerations at critical reactor components (e.g., cylindrical wall and reactor vessel) are reduced by up to 55% due to this favorable dynamic interaction.
  • The results demonstrate that SSSI can provide mutual seismic protection when properly tuned, suggesting potential for designing resilient building clusters or 'meta-cities' in seismic zones.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.