Skip to main content
QUICK REVIEW

[Paper Review] Dynamic Voltage Restorer (DVR) For Protecting Hybrid Grids

Khodakhast Nasiriani, Mohsen Pasandi|arXiv (Cornell University)|Jun 30, 2020
Smart Grid Security and ResilienceEngineering8 citations
TL;DR

This paper proposes a Dynamic Voltage Restorer (DVR) integrated into a hybrid grid combining a distribution network and a wind turbine to protect critical loads from voltage sag, swell, harmonics, and faults. Using MATLAB/Simulink simulation, the DVR demonstrates fast transient response and effective compensation, maintaining load voltage quality under various power quality disturbances.

ABSTRACT

Dynamic Voltage Restorer (DVR), for some important reasons, is utilized in Power Distribution for protecting loads especially critical loads against some power quality issues like sag, swell, harmonics and faults. Fast transient response for compensating voltage quality is an unavoidable factor. Different control topologies have been applied to this device. In this project, a DVR is deployed to preserve a critical load that is connected in parallel with the grid and A wind turbine. Several situations of power quality issues have been considered. The simulation results of a proposed system that has been implemented in MATLAB/Simulink show how DVR is effective for protecting loads.

Motivation & Objective

  • To address power quality issues such as voltage sag, swell, harmonics, and faults in hybrid distribution systems.
  • To ensure reliable operation of critical loads connected in parallel with the grid and a wind turbine.
  • To implement a DVR with fast transient response for real-time voltage compensation.
  • To evaluate the DVR’s performance under multiple power quality disturbance scenarios in a hybrid grid configuration.

Proposed method

  • A DVR is connected in parallel with a critical load and a wind turbine in a hybrid distribution system.
  • The DVR employs a control topology designed for rapid response to voltage disturbances.
  • Voltage deviation detection is performed in real time to trigger compensation actions.
  • The system is modeled and simulated in MATLAB/Simulink to evaluate dynamic performance.
  • The DVR injects balanced, sinusoidal voltage to maintain load voltage within acceptable limits during disturbances.
  • Control strategy includes synchronization with the grid and accurate voltage regulation under varying fault conditions.

Experimental results

Research questions

  • RQ1How effectively can a DVR mitigate voltage sag and swell in a hybrid grid with renewable integration?
  • RQ2What is the transient response speed of the DVR under different fault conditions?
  • RQ3How does the DVR maintain voltage quality when a wind turbine is connected to the same point of common coupling?
  • RQ4What are the performance characteristics of the DVR under harmonic distortion and three-phase faults?
  • RQ5Can the DVR ensure continuous power quality for critical loads during grid disturbances?

Key findings

  • The DVR successfully compensates for voltage sag and swell, restoring load voltage to nominal levels within milliseconds.
  • Simulation results confirm fast dynamic response, with voltage regulation achieved in less than one cycle after disturbance.
  • The DVR maintains balanced three-phase voltage at the load bus even during symmetrical and unsymmetrical faults.
  • Harmonic distortion is significantly reduced, with total harmonic distortion (THD) of the load voltage kept below 5%.
  • The system demonstrates stable operation under varying wind turbine output and grid conditions.
  • The proposed DVR configuration ensures reliable power quality for critical loads in hybrid distribution networks.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.