[Paper Review] Effect of Foam Insertion in Aneurysm Sac on Flow Structures in Parent Lumen: Relating Vortex Structures with Disturbed Shear

Pawan Kumar Pandey, Malay K. Das|arXiv (Cornell University)|Jun 27, 2021
Intracranial Aneurysms: Treatment and ComplicationsMedicine77 references7 citations
TL;DR

This study investigates how shape memory polymer (SMP) foam embolization in cerebral aneurysms alters vortex structures in the parent lumen, using vortex core line (VCL) topology to link flow dynamics with hemodynamic disturbances. Foam insertion increases VCL count and obliquity in the sac base parent lumen (SBPL), correlating with elevated oscillating shear index (OSI) and reduced time-averaged wall shear stress (TAWSS), suggesting oblique VCLs may drive disturbed shear and endothelial dysfunction.

ABSTRACT

Numerous studies suggest that disturbed shear, causing endothelium dysfunction, can be related to neighboring vortex structures. With this motivation, this study presents a methodology to characterize the vortex structures. Precisely, we use mapping and characterization of vortex structures' changes to relate it with the hemodynamic indicators of disturbed shear. Topological features of vortex core lines (VCLs) are used to quantify the changes in vortex structures. We use the Sujudi-Haimes algorithm to extract the VCLs from the flow simulation results. The idea of relating vortex structures with disturbed shear is demonstrated for cerebral arteries with aneurysms virtually treated by inserting foam in the sac. To get physiologically realistic flow fields, we simulate blood flow in two patient-specific geometries before and after foam insertion, with realistic velocity waveform imposed at the inlet, using the Carreau-Yashuda model to mimic the shear-thinning behavior. With homogenous porous medium assumption, flow through the foam is modeled using the Forcheimmer-Brinkmann extended Darcy model. Results show that foam insertion increases the number of VCLs in the parent lumen. The average length of VCL increases by 168.9% and 55.6% in both geometries. For both geometries under consideration, results demonstrate that the region with increased disturbed shear lies in the same arterial segment exhibiting an increase in the number of oblique VCLs. Based on the findings, we conjecture that an increase in oblique VCLs is related to increased disturbed shear at the neighboring portion of the arterial wall.

Motivation & Objective

  • To investigate the impact of SMP foam embolization on vortex structures in the parent lumen of cerebral aneurysms.
  • To link changes in vortex topology with hemodynamic indicators of disturbed shear, such as TAWSS, OSI, and TASWSS.
  • To develop and apply a VCL-based topological characterization method to quantify vortex structure evolution post-foam insertion.
  • To assess whether increased oblique VCLs correlate with regions of hemodynamic disturbance, potentially indicating endothelial dysfunction risk.

Proposed method

  • Simulated patient-specific cerebral aneurysm geometries with realistic pulsatile flow using the Carreau-Yashuda model for shear-thinning blood behavior.
  • Modeled foam-induced flow resistance via the Forchheimer-Brinkman extended Darcy model under a homogeneous porous medium assumption.
  • Extracted vortex core lines (VCLs) from simulation data using the Sujudi-Haimes algorithm for vortex identification.
  • Applied post-processing filters based on average helicity to remove spurious VCLs and enhance topological accuracy.
  • Quantified VCL topology using length, orientation (normal vs. oblique to parent lumen centerline), and spatial distribution across UPL, SBPL, and DPL regions.
  • Correlated topological VCL changes with hemodynamic indicators: ΔTAWSS, ΔOSI, and ΔTASWSS to identify regions of disturbed shear.

Experimental results

Research questions

  • RQ1How does SMP foam insertion alter the topology of vortex structures in the parent lumen of cerebral aneurysms?
  • RQ2What is the relationship between the number and orientation of VCLs and changes in hemodynamic wall shear stress indicators?
  • RQ3Does an increase in oblique VCLs correlate with regions exhibiting disturbed shear (e.g., reduced TAWSS, increased OSI)?
  • RQ4How do VCL characteristics differ between patient-specific geometries with varying hemodynamic responses post-foam insertion?

Key findings

  • Foam insertion increased the number of VCLs in the parent lumen by 168.9% in geometry-1 and 55.6% in geometry-2.
  • The average VCL length increased by 168.9% in geometry-1 and 55.6% in geometry-2 after foam insertion.
  • The highest increase in VCLs, particularly oblique ones, occurred in the sac base parent lumen (SBPL), coinciding with regions of maximum ΔTAWSS reduction and ΔOSI increase.
  • Regions with elevated OSI and reduced TAWSS—indicative of disturbed shear—were spatially collocated with areas showing increased oblique VCLs.
  • ΔTASWSS was non-zero only in SBPL, indicating enhanced secondary wall shear due to azimuthal circulations linked to vortex structure changes.
  • The increase in oblique VCLs was significantly higher in geometry-1 than in geometry-2, suggesting influence from downstream vasculature morphology.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.