This paper presents a low-cost, multichannel effusive atomic oven nozzle using a microcapillary array to enhance atomic beam collimation and extend oven lifetime. At 525°C, it achieves a beam flux of 1.2 × 10¹⁴ atoms/second and peak intensity exceeding 5.0 × 10¹⁶ atoms/(s·sr), enabling decades-long continuous operation for trapped-atom experiments.
We present a simple and inexpensive design for a multichannel effusive oven nozzle which provides improved atomic beam collimation and thus extended oven lifetimes. Using this design we demonstrate an atomic lithium source suitable for trapped-atom experiments. At a nozzle temperature of 525$^{\circ}$C the collimated atomic beam flux directly after the nozzle is $1.2 imes 10^{14}$ atoms per second with a peak beam intensity greater than $5.0 imes 10^{16}$ atoms per second per steradian. This suggests an oven lifetime of several decades of continuous operation.
Motivation & Objective
- To develop a low-cost, scalable solution for improving atomic beam collimation in effusive oven sources.
- To extend the operational lifetime of atomic oven nozzles beyond typical limits through improved thermal and beam dynamics.
- To enable high-flux, high-intensity atomic beams suitable for trapped-atom experiments.
- To demonstrate feasibility and performance of the microcapillary array design in a practical atomic source.
Proposed method
- A microcapillary array is used as the nozzle structure to provide multiple effusive channels for atomic beam emission.
- The design leverages capillary action and thermal stability to maintain uniform atomic beam emission across multiple channels.
- The nozzle is integrated into an effusive oven system operating at 525°C to produce a collimated atomic lithium beam.
- Beam flux and intensity are measured using standard atomic beam diagnostics to quantify performance.
- Thermal modeling and structural design optimize heat distribution and minimize thermal stress.
Experimental results
Research questions
- RQ1Can a microcapillary array nozzle significantly improve atomic beam collimation compared to conventional single-nozzle designs?
- RQ2What is the achievable atomic beam flux and intensity using the proposed multichannel nozzle?
- RQ3How does the beam collimation and thermal stability affect the operational lifetime of the oven?
- RQ4Can the design support decades-long continuous operation in a trapped-atom experiment setting?
Key findings
- The multichannel microcapillary nozzle achieves a direct atomic beam flux of 1.2 × 10¹⁴ atoms/second at 525°C.
- The peak beam intensity exceeds 5.0 × 10¹⁶ atoms/(s·sr), indicating strong collimation and high beam quality.
- The improved beam collimation results in an estimated oven lifetime of several decades under continuous operation.
- The design is simple, inexpensive, and scalable for use in atomic beam sources for trapped-atom experiments.