Skip to main content
QUICK REVIEW

[Paper Review] Enabling Wireless Power Transfer in Cellular Networks: Architecture, Modeling and Deployment

Kaibin Huang, Vincent K. N. Lau|arXiv (Cornell University)|Jul 24, 2012
Energy Harvesting in Wireless NetworksEngineering19 references18 citations
TL;DR

This paper proposes a hybrid cellular network architecture overlaying uplink base stations with randomly deployed power beacons (PBs) for microwave power transfer (MPT) to enable wireless charging. Using stochastic geometry with Poisson point processes, it derives key tradeoffs showing that for isotropic MPT, $ q au_p au_b^{ rac{ au}{2}} $ must exceed a threshold, while for directed MPT, array gain $ z_m $ and $ (z_m q)^{ rac{2}{ au}} au_b $ must be sufficiently large to ensure reliable power delivery under outage constraints.

ABSTRACT

Microwave power transfer (MPT) delivers energy wirelessly from stations called power beacons (PBs) to mobile devices by microwave radiation. This provides mobiles practically infinite battery lives and eliminates the need of power cords and chargers. To enable MPT for mobile charging, this paper proposes a new network architecture that overlays an uplink cellular network with randomly deployed PBs for powering mobiles, called a hybrid network. The deployment of the hybrid network under an outage constraint on data links is investigated based on a stochastic-geometry model where single-antenna base stations (BSs) and PBs form independent homogeneous Poisson point processes (PPPs) and single-antenna mobiles are uniformly distributed in Voronoi cells generated by BSs. In this model, mobiles and PBs fix their transmission power at p and q, respectively; a PB either radiates isotropically, called isotropic MPT, or directs energy towards target mobiles by beamforming, called directed MPT. The model is applied to derive the tradeoffs between the network parameters including p, q, and the BS/PB densities under the outage constraint. First, consider the deployment of the cellular network. It is proved that the outage constraint is satisfied so long as the product the BS density decreases with increasing p following a power law where the exponent is proportional to the path-loss exponent. Next, consider the deployment of the hybrid network assuming infinite energy storage at mobiles. It is shown that for isotropic MPT, the product between q, the PB density, and the BS density raised to a power proportional to the path-loss exponent has to be above a given threshold so that PBs are sufficiently dense; for directed MPT, a similar result is obtained with the aforementioned product increased by the array gain. Last, similar results are derived for the case of mobiles having small energy storage.

Motivation & Objective

  • To enable wireless power transfer (WPT) in cellular networks using microwave power transfer (MPT) via dedicated power beacons (PBs).
  • To address the challenge of maintaining reliable uplink cellular connectivity while powering mobile devices wirelessly.
  • To model and analyze the tradeoffs between PB and base station (BS) densities, transmission powers, and beamforming techniques under outage constraints.
  • To provide design guidelines for deploying hybrid networks with isotropic or directed MPT for mobiles with large or small energy storage capacity.

Proposed method

  • Models the network using independent homogeneous Poisson point processes (PPPs) for base stations (BSs) and power beacons (PBs), with mobiles uniformly distributed in Voronoi cells of BSs.
  • Applies stochastic geometry to analyze the outage probability of uplink data links under the constraint that mobiles must receive sufficient power from PBs.
  • Considers two MPT modes: isotropic radiation (omnidirectional PBs) and directed MPT (beamforming toward target mobiles) with array gain $ z_m $.
  • Derives analytical expressions for the required product of PB transmission power $ q $, PB density $ au_p $, and BS density $ au_b $, scaled by path-loss exponent $ \alpha $.
  • Uses Lemma 3 for numerical computation of feasible parameter regions when mobiles have large energy storage, and simulation for small storage cases.
  • Incorporates the impact of array gain $ z_m $ in beamforming to model effective power increase and derive modified thresholds for directed MPT.

Experimental results

Research questions

  • RQ1What is the minimum mobile transmit power required to maintain uplink outage constraint as a function of base station density in a cellular network?
  • RQ2How do PB transmission power $ q $, PB density $ \tau_p $, and BS density $ \tau_b $ trade off to ensure reliable energy transfer under isotropic MPT?
  • RQ3How does beamforming (directed MPT) with array gain $ z_m $ affect the required PB density and transmission power compared to isotropic MPT?
  • RQ4What are the critical thresholds for $ q\tau_p\tau_b^{\alpha/2} $ and $ (z_m q)^{2/\alpha}\tau_b $ in ensuring sufficient power delivery under different storage and MPT configurations?
  • RQ5How does limited energy storage at mobiles affect the feasibility of hybrid network deployment and the required PB density?

Key findings

  • For the cellular network alone, the outage constraint is satisfied if $ p\tau_b^{\alpha/2} $ exceeds a threshold, independent of noise due to the absence of interference in the analysis.
  • For isotropic MPT with large mobile energy storage, the product $ q\tau_p\tau_b^{\alpha/2} $ must exceed a given threshold to ensure sufficient power delivery.
  • For directed MPT with large storage, the product $ z_m q \tau_p \tau_b^{\alpha/2} $ must exceed a different threshold, with array gain $ z_m $ effectively increasing the effective power transfer.
  • In directed MPT, $ (z_m q)^{2/\alpha} \tau_b $ must be sufficiently large to ensure adequate power delivery regardless of distance, otherwise PBs cannot meet the minimum power requirement.
  • For mobiles with small energy storage, both $ q^{2/\alpha} \tau_p \tau_b^{\alpha/\alpha} $ and $ q^{2/\alpha} \tau_b $ must be large enough to compensate for energy accumulation from multiple PBs.
  • Feasibility regions show that isotropic MPT performs better at low BS densities, while directed MPT becomes more efficient at high BS densities due to reduced reliance on side-lobe power.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.