TL;DR

This paper presents an energy-efficient, tree-based EEG artifact detection system using a minimal 4-channel temporal EEG setup, optimized via automated machine learning (TPOT) and deployed on a PULP ultra-low-power platform. It achieves 93.95% accuracy and 4.71 µJ per inference, outperforming state-of-the-art methods in both accuracy and energy efficiency for wearable epilepsy monitoring systems.

ABSTRACT

In the context of epilepsy monitoring, EEG artifacts are often mistaken for seizures due to their morphological similarity in both amplitude and frequency, making seizure detection systems susceptible to higher false alarm rates. In this work we present the implementation of an artifact detection algorithm based on a minimal number of EEG channels on a parallel ultra-low-power (PULP) embedded platform. The analyses are based on the TUH EEG Artifact Corpus dataset and focus on the temporal electrodes. First, we extract optimal feature models in the frequency domain using an automated machine learning framework, achieving a 93.95% accuracy, with a 0.838 F1 score for a 4 temporal EEG channel setup. The achieved accuracy levels surpass state-of-the-art by nearly 20%. Then, these algorithms are parallelized and optimized for a PULP platform, achieving a 5.21 times improvement of energy-efficient compared to state-of-the-art low-power implementations of artifact detection frameworks. Combining this model with a low-power seizure detection algorithm would allow for 300h of continuous monitoring on a 300 mAh battery in a wearable form factor and power budget. These results pave the way for implementing affordable, wearable, long-term epilepsy monitoring solutions with low false-positive rates and high sensitivity, meeting both patients' and caregivers' requirements.

Motivation & Objective

  • To develop a low-power, accurate EEG artifact detection system suitable for wearable, long-term epilepsy monitoring.
  • To address the high false-positive rate in seizure detection caused by morphological similarity between artifacts and seizures.
  • To optimize artifact detection performance using automated machine learning on the TUH EEG Artifact Corpus.
  • To implement and minimize energy consumption of the detection framework on a real ultra-low-power embedded platform (Mr. Wolf).

Proposed method

  • Employed Fast Fourier Transform (FFT) and Discrete Wavelet Transform (DWT) for frequency-domain signal pre-processing.
  • Used the TPOT automated machine learning framework to search for optimal ensemble tree models across binary, multi-label, and multi-class multi-output classification tasks.
  • Designed a decision tree ensemble (Extra Trees) with pruning via the MCCP algorithm to reduce model size and memory footprint.
  • Optimized the model for parallel execution on the 8-core Mr. Wolf PULP platform, aligning tree count to multiples of 8 for efficient multi-core execution.
  • Measured energy consumption on the Mr. Wolf chip, achieving sub-200 µs inference time and 4.71 µJ per inference for the MMC case.
  • Combined the artifact detection model with prior low-energy seizure detection models to enable 300h of continuous monitoring on a 300 mAh battery.

Experimental results

Research questions

  • RQ1Can automated machine learning identify optimal tree-based models for EEG artifact detection with minimal EEG channels?
  • RQ2How does the accuracy of artifact detection vary across different classification paradigms (binary, multi-label, multi-class multi-output) on the TUH EEG Artifact Corpus?
  • RQ3What is the achievable energy efficiency of a tree-based artifact detection system when deployed on an ultra-low-power embedded platform like Mr. Wolf?
  • RQ4To what extent can model pruning and parallelization reduce memory footprint and energy consumption without sacrificing accuracy?
  • RQ5Can the proposed artifact detection system be integrated with low-energy seizure detection to enable long-term, wearable epilepsy monitoring?

Key findings

  • The proposed system achieved 93.95% test accuracy on the TUH EEG Artifact Corpus using a 4-channel temporal EEG setup, surpassing prior state-of-the-art by nearly 20%.
  • The model achieved a 0.838 F1 score in the multi-class multi-output classification setting, matching the best reported F1 score but with significantly higher accuracy.
  • Energy consumption was reduced to 4.71 µJ per inference on the Mr. Wolf platform, representing a 5.21× improvement in energy efficiency over existing low-power implementations.
  • Model size was reduced from 11,000 kB to 2,300 kB with only a 1% accuracy drop by limiting the number of decision trees to multiples of 8 for parallel execution.
  • The system enables up to 300 hours of continuous EEG monitoring on a 300 mAh battery when combined with a low-power seizure detection algorithm.
  • Pruning via MCCP maintained high accuracy (92.4% for BC case) even when fitting within the 512 kB L2 memory, validating the robustness of the optimized embedded implementation.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.