[Paper Review] Energy Optimization for HVAC Systems in Multi-VAV Open Offices: A Deep Reinforcement Learning Approach
This paper proposes a low-complexity deep reinforcement learning (DRL) framework for HVAC control in multi-zone open-plan offices, using only accessible inputs like temperature, occupancy, and outdoor weather to optimize energy use and thermal comfort. It achieves 37% energy savings with less than 1% temperature violation and trains in just 40 minutes, while enforcing smooth control to reduce mechanical wear and occupant discomfort.
With more than 32% of the global energy used by commercial and residential buildings, there is an urgent need to revisit traditional approaches to Building Energy Management (BEM). With HVAC systems accounting for about 40% of the total energy cost in the commercial sector, we propose a low-complexity DRL-based model with multi-input multi-output architecture for the HVAC energy optimization of open-plan offices, which uses only a handful of controllable and accessible factors. The efficacy of our solution is evaluated through extensive analysis of the overall energy consumption and thermal comfort levels compared to a baseline system based on the existing HVAC schedule in a real building. This comparison shows that our method achieves 37% savings in energy consumption with minimum violation (<1%) of the desired temperature range during work hours. It takes only a total of 40 minutes for 5 epochs (about 7.75 minutes per epoch) to train a network with superior performance and covering diverse conditions for its low-complexity architecture; therefore, it easily adapts to changes in the building setups, weather conditions, occupancy rate, etc. Moreover, by enforcing smoothness on the control strategy, we suppress the frequent and unpleasant on/off transitions on HVAC units to avoid occupant discomfort and potential damage to the system. The generalizability of our model is verified by applying it to different building models and under various weather conditions.
Motivation & Objective
- To address the lack of effective, generalizable, and efficient HVAC control methods for multi-VAV open-plan offices.
- To optimize energy efficiency and thermal comfort simultaneously without relying on complex physics models or inaccessible data.
- To reduce training time and improve adaptability to changing building conditions, such as occupancy and weather.
- To minimize HVAC on/off transitions to prevent occupant discomfort and equipment wear.
- To validate the model’s generalizability across different floor plans and diverse climate conditions.
Proposed method
- A multi-input, multi-output DRL agent is trained using a reward function that balances energy savings and thermal comfort, penalizing deviations from the target temperature range.
- The action space is defined by discrete on/off states of 6 VAV boxes, resulting in 64 total actions, with heuristic optimization used to manage scalability.
- A signal smoothness control term is introduced to suppress frequent on/off transitions, improving system longevity and occupant comfort.
- The DRL framework uses only accessible, real-time inputs: zone temperatures, outdoor weather, occupancy rate, and CO2 levels.
- Experience replay is employed to stabilize training, and the model is trained on data from a real-world open-plan office building.
- Generalizability is tested by applying the trained policy to different building layouts and weather conditions without retraining.
Experimental results
Research questions
- RQ1Can a data-driven DRL approach effectively optimize HVAC energy use in multi-zone open-plan offices with inter-zone heat transfer?
- RQ2How does the proposed method compare to rule-based scheduling in terms of energy savings and thermal comfort?
- RQ3To what extent does the model generalize across different building floor plans and varying outdoor weather conditions?
- RQ4Can the DRL agent achieve high performance with minimal training time and low computational complexity?
- RQ5How effective is the smoothness control term in reducing HVAC on/off transitions and improving occupant comfort?
Key findings
- The proposed DRL method achieved a 37% reduction in HVAC energy consumption compared to the baseline rule-based system during work hours.
- Thermal comfort violations were kept below 1% of the time, indicating strong adherence to the desired temperature range.
- The model trained in only 40 minutes (about 7.75 minutes per epoch) across five epochs, significantly faster than weeks or months required by other methods.
- The method demonstrated strong generalizability, maintaining high performance when applied to different building floor plans and under diverse weather conditions.
- The smoothness control term effectively reduced frequent on/off transitions, minimizing mechanical stress and occupant discomfort.
- Energy savings were highest in cooler climates (e.g., 40% in Minneapolis), while regions with higher mean outdoor temperatures (e.g., Phoenix, Miami) saw lower savings (17–30%) due to greater cooling demands.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.