This paper proposes a novel architecture using two electron pumps with moderate error rates (10⁻⁵) and intermediate charge monitoring via sensitive electrometers to achieve ultra-low error rates (10⁻⁸) in electron counting experiments. By counting only errors rather than all electrons, the method enables high-accuracy current and capacitance standards with significantly relaxed requirements on individual device performance, allowing higher operation frequencies and improved yield through parallelization.
Electron counting experiments attempt to provide a current of a known number of electrons per unit time. We propose architectures utilizing a few readily available electron-pumps or turnstiles with the typical error rates of 100 ppm with common sensitive electrometers to achieve the desirable accuracy of 1 part in 10 ppb. This is achieved not by counting all transferred electrons but by counting only the errors of individual devices; these are less frequent and therefore readily recognized and accounted for. We thereby ease the route towards quantum based standards for current and capacitance.
Motivation & Objective
- To overcome the challenge of achieving 1 part in 10⁸ error rate in electron counting experiments for quantum-based metrology.
- To reduce reliance on ultra-high-quality individual electron pumps by focusing on error accounting rather than full electron counting.
- To enable practical, scalable current and capacitance standards by relaxing device performance requirements through architectural innovation.
- To allow higher pump frequencies and parallelization by mitigating error accumulation in multi-device systems.
- To provide a framework for monitoring and correcting individual pump errors at the single-electron level, facilitating device evaluation and optimization.
Proposed method
- Use two electron pumps in series with an intermediate node whose charge is monitored by a sensitive electrometer such as an RF-SET.
- Leverage the fact that error events (±1 electron) are rarer than full electron transfers, making them easier to detect and correct.
- Apply Bayesian inference to estimate the probability distribution of charge states on the intermediate node using real-time electrometer signals.
- Model the system using a Fokker-Planck-type equation for charge diffusion, with stochastic evolution governed by the signal-to-noise ratio of the electrometer.
- Use numerical integration of the stochastic differential equation ẟπ̲ = (T + U)π̲ to simulate and correct for measurement noise and diffusion dynamics.
- Implement a feedback-like correction algorithm that subtracts perceived errors from the underlying diffusion, reducing effective error rates by up to 10⁴-fold.
Experimental results
Research questions
- RQ1Can error rates in electron counting be reduced to 10⁻⁸ by monitoring only error events rather than all electron transfers?
- RQ2To what extent can device quality requirements be relaxed if error events are individually detected and corrected?
- RQ3How does the combination of two pumps with moderate error rates (10⁻⁵) and sensitive electrometers enable a 10⁴ to 10⁵ improvement in effective error rate?
- RQ4Can this architecture support higher pump frequencies or parallelization without compromising accuracy?
- RQ5Can single-gate electron pumps with higher error rates be made suitable for metrological applications through this error-accounting framework?
Key findings
- The proposed architecture achieves a 10,000-fold reduction in effective error rate even with individual pumps having a relative error rate of 100 ppm (10⁻⁵).
- With three pumps and two electrometers, a pump error rate of 200 errors per second can be corrected to yield an effective error rate below 10 ppb (10⁻¹⁰), meeting metrological standards.
- For five-pump configurations, error rates up to 8,000 errors per second can be corrected to below 10 ppb, enabling higher current output.
- A 100 ppm error rate per pump allows operation at 2 MHz with three devices or 80 MHz with five, significantly increasing current output while maintaining accuracy.
- With 10 ppm error rate devices, only a 1,000-fold improvement is needed, achievable with five pumps and a 1 GHz pump frequency, enabling high-current metrology.
- The method enables single-electron-level monitoring of pump error rates, a capability previously unavailable for single-gate devices, thus supporting their evaluation for metrological use.
Read this paper