Skip to main content
QUICK REVIEW

[Paper Review] ESAD: Endoscopic Surgeon Action Detection Dataset

Vivek Singh Bawa, Gurkirt Singh|arXiv (Cornell University)|Jun 12, 2020
Surgical Simulation and TrainingMedicine8 citations
TL;DR

This paper introduces ESAD, the first large-scale dataset for endoscopic surgeon action detection in real prostatectomy videos, annotated with tool-level bounding boxes and action labels. It proposes a frame-level action detection baseline using SSD with ResNet backbones and two loss functions (Focal and OHEM), achieving a mean AP of 16.1 on the test set, establishing a benchmark for surgical robotics and AI-assisted surgery research.

ABSTRACT

In this work, we take aim towards increasing the effectiveness of surgical assistant robots. We intended to make assistant robots safer by making them aware about the actions of surgeon, so it can take appropriate assisting actions. In other words, we aim to solve the problem of surgeon action detection in endoscopic videos. To this, we introduce a challenging dataset for surgeon action detection in real-world endoscopic videos. Action classes are picked based on the feedback of surgeons and annotated by medical professional. Given a video frame, we draw bounding box around surgical tool which is performing action and label it with action label. Finally, we presenta frame-level action detection baseline model based on recent advances in ob-ject detection. Results on our new dataset show that our presented dataset provides enough interesting challenges for future method and it can serveas strong benchmark corresponding research in surgeon action detection in endoscopic videos.

Motivation & Objective

  • To address the lack of real-world datasets for surgeon action detection in minimally invasive surgery (MIS) videos.
  • To improve safety and effectiveness of surgical assistant robots by enabling real-time awareness of surgeon actions.
  • To provide a standardized benchmark for developing and evaluating AI models in endoscopic surgical video analysis.
  • To support research in autonomous surgical assistants, anomaly detection, and surgeon feedback systems.

Proposed method

  • The dataset, ESAD, contains real endoscopic videos from prostatectomy procedures, annotated with action labels and tool-specific bounding boxes.
  • Action classes were selected based on surgeon feedback and verified by medical professionals to ensure clinical relevance.
  • A frame-level action detection baseline model was developed using a single-shot detector (SSD) with ResNet backbones for feature extraction.
  • Two loss functions—Focal Loss and Online Hard Example Mining (OHEM)—were evaluated to handle class imbalance and improve detection accuracy.
  • The model was trained on multiple input image sizes (200–800) and with different backbone networks (ResNet18 to ResNet101) to assess performance trade-offs.
  • Evaluation used three IOU thresholds (0.1, 0.3, 0.5) to compute AP10, AP30, AP50, and mean AP for both validation and test sets.

Experimental results

Research questions

  • RQ1Can a real-world, clinically relevant dataset for endoscopic surgeon action detection be constructed with accurate tool-level annotations?
  • RQ2How do different loss functions (Focal vs. OHEM) affect detection performance in surgical video action detection?
  • RQ3What is the impact of input image resolution and backbone network depth on model performance in this challenging medical vision task?
  • RQ4To what extent does the proposed baseline model generalize to unseen test data in real surgical video sequences?

Key findings

  • The Focal Loss-based model achieved the highest test-set mean AP of 16.1, indicating better generalization on unseen data.
  • The OHEM loss performed better on the validation set (mean AP 24.4) but underperformed on the test set, suggesting overfitting to validation data.
  • Larger input image sizes (e.g., 800) did not consistently improve test performance, though they improved validation scores with OHEM loss.
  • Medium-depth backbones like ResNet34 and ResNet50 outperformed deeper models (e.g., ResNet101), indicating optimal complexity for this task.
  • The dataset presents significant challenges, as even the best baseline model achieved only 16.1% mean AP on the test set, highlighting the need for future methodological advances.
  • The results confirm that standard computer vision methods are insufficient for this domain, validating the need for a dedicated benchmark like ESAD.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.