Skip to main content
QUICK REVIEW

[Paper Review] Estimating Phase Aberration from Noisy Radiofrequency Data of a single frame of Synthetic Aperture Ultrasound Image

Dena Monjazebi, Yuan Xu|arXiv (Cornell University)|Jun 21, 2021
Ultrasound Imaging and ElastographyMedicine30 references5 citations
TL;DR

This paper proposes an iterative filtered normalized cross-correlation (f-NCC) method to estimate phase aberration from low-signal-to-noise-ratio (SNR) radiofrequency (RF) data in a single-frame synthetic transmit aperture (STA) ultrasound image. By applying 2D aperture-temporal filtering, iterative delay estimation with phase aberration modeling in transmit and receive processes, and edge-effect correction via iterative zero-padding, the method improves phase aberration estimation accuracy even in noisy speckle regions, leading to enhanced image contrast, resolution, and SNR in both simulations and experiments.

ABSTRACT

Phase aberration is one of the main contributors to image degradation in ultrasound imaging. Normalized-Cross-Correlation (NCC) is one of the most extensively studied techniques to estimate the arrival delay error and the aberration profile. extit{However, the performance of NCC can be compromised when the data have a poor signal-to-noise-ratio.} Here we propose an iterative filtered NCC (f-NCC) method to estimate phase aberration in speckle regions from the noisy radio-frequency data of a single frame of synthetic transmit aperture (STA) image. First, two-dimensional filters were applied in the aperture and temporal domains to suppress noise and off-axis signals in the transmit beamformed data from an arbitrary speckle region. Second, an iterative method that included the phase aberration in both the transmission and receiving process was used to estimate the phase aberration. Third, the estimation were improved by correcting the edge effect with an iterative zero-padding technique. Last, in the experimental study, we proposed and validated a formula to estimate the arrival time error caused by a sound speed error. The results from both the numerical simulations and experimental studies confirm that the proposed filtered NCC method can estimate the phase aberration profile correctly from noisy STA RF data in a speckle region. Image quality in terms of contrast, resolution and image signal-to-noise-ratio was improved. Potential applications of the proposed method to map local speed of samples are also discussed.

Motivation & Objective

  • To address the challenge of inaccurate phase aberration estimation in low-SNR ultrasound RF data, particularly in obese or breast imaging where signal degradation is common.
  • To improve the performance of normalized cross-correlation (NCC) in noisy conditions by integrating spatial and temporal filtering in the aperture and temporal domains.
  • To reduce edge artifacts in delay estimation caused by periodic signal assumptions in Fourier transforms via an iterative zero-padding technique.
  • To validate the method on both numerical simulations and experimental data, demonstrating robustness in noisy speckle regions.
  • To enable accurate local speed-of-sound mapping by deriving a theoretical formula for delay errors due to sound speed mismatches.

Proposed method

  • Applying a 2D low-pass filter in the aperture and temporal domains to suppress noise and off-axis signals in transmit beamformed RF data from a speckle region.
  • Implementing an iterative f-NCC algorithm that models phase aberration in both transmission and reception processes to refine delay estimation.
  • Using an iterative zero-padding technique to mitigate edge effects caused by discontinuities in the signal when applying Fourier transforms.
  • Integrating the estimated phase aberration profile into the beamforming process to compensate for wavefront distortions.
  • Deriving a theoretical formula for delay error due to sound speed mismatch, accounting for both direct speed error and focal point shift effects.
  • Validating the method using both simulated data with known aberration profiles and experimental data from ultrasound phantoms.

Experimental results

Research questions

  • RQ1Can the f-NCC method accurately estimate phase aberration in low-SNR RF data from a single-frame synthetic transmit aperture (STA) ultrasound image?
  • RQ2How does 2D aperture-temporal filtering improve the robustness of NCC-based delay estimation in noisy speckle regions?
  • RQ3To what extent does iterative zero-padding reduce edge-related artifacts in phase aberration estimation?
  • RQ4How does the proposed method improve image quality metrics such as contrast, resolution, and SNR in low-SNR conditions?
  • RQ5Can the derived theoretical formula accurately predict delay errors caused by sound speed mismatches in ultrasound imaging?

Key findings

  • The f-NCC method successfully estimated phase aberration profiles from noisy STA RF data in speckle regions, outperforming standard NCC under low SNR conditions.
  • Image quality improved significantly, with enhanced contrast, lateral resolution, and signal-to-noise ratio (SNR) after aberration correction.
  • The iterative zero-padding technique effectively reduced edge artifacts in delay estimation, particularly at the first and last 10 transducer elements.
  • Theoretical analysis confirmed that total delay error due to sound speed mismatch is proportional to δtc(1 + cosθi), where δtc accounts for speed error and focal shift.
  • The method demonstrated convergence within 2–3 iterations, indicating computational efficiency and stability.
  • The approach enables potential applications in local speed-of-sound mapping, offering a pathway for clinical adaptation in challenging imaging scenarios like obese patients.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.