[Paper Review] A gel wax phantom for performance evaluation in diagnostic ultrasound: assessment of image uniformity, geometric accuracy, and diameter of a hyperechoic target
This study presents a low-cost, stable gel wax phantom for ultrasound performance evaluation, using embedded stainless-steel discs and nylon filaments to assess image uniformity, geometric accuracy, and target diameter. The phantom demonstrated high stability (1.8% volume loss over 62 weeks) and accurate measurements with a maximum distance error of 7.1% in US imaging, validating its use in diagnostic ultrasound quality control.
Purpose: To develop and validate a phantom for diagnostic ultrasound (US) scanners by embedding targets in gel wax to determine the image uniformity, lateral and axial resolution, and diameter of a stainless-steel disc. Materials and Methods: Acoustic property (AP), which includes the velocity of US (cus), acoustic impedance (Z), and attenuation coefficient in gel wax were determined. The cus, and attenuation coefficient were estimated using the pulse-echo technique. Z was obtained from the product of sample density ( {ho}) and cus. Two rectangular frames using polytetrafluoroethylene (PTFE) sheets with holes separated by 5, 10, and 20 mm distances were constructed. Nylon filaments and SS-disc (diameter = 16.8 mm) were threaded through the frames and suitably placed in melted gel wax to obtain orthogonal targets. The targets were measured using computerized tomography (CT) and a 2-9 MHz US probe. Results: The AP of gel wax were cus=1418 m/s, {ho}= 0.87 g/cm3, Z=1.23 MRayls, attenuation coefficient= 0.88 dB/cm/MHz. The results of US imaging of the targets were compared with their physical sizes and served as baselines for the scanner and probe. The maximum error in distance measurement in the phantom US images was 7.1%, and the phantom volume decreased by 1.8% over 62 weeks. Conclusion: Gel wax can be useful in developing affordable, highly stable, and customizable diagnostic US phantoms that can be implemented widely.
Motivation & Objective
- To develop an affordable, stable, and customizable phantom for diagnostic ultrasound performance evaluation.
- To assess image uniformity, geometric accuracy, and diameter measurement of hyperechoic targets in ultrasound imaging.
- To validate the acoustic properties of gel wax as a suitable medium for ultrasound phantoms.
- To provide a baseline for scanner and probe performance using physical measurements from CT and US imaging.
- To support widespread implementation of phantoms in clinical and research settings through low-cost, accessible materials.
Proposed method
- Acoustic properties of gel wax were measured using the pulse-echo technique to determine sound velocity (cus), acoustic impedance (Z), and attenuation coefficient.
- Two rectangular frames made of polytetrafluoroethylene (PTFE) with 5, 10, and 20 mm hole separations were fabricated to position targets.
- Stainless-steel discs (16.8 mm diameter) and nylon filaments were embedded in melted gel wax to create orthogonal targets.
- The phantom was scanned using a 2–9 MHz ultrasound probe and CT for physical size validation.
- Image uniformity, lateral and axial resolution, and target diameter were evaluated by comparing US measurements to physical dimensions from CT.
Experimental results
Research questions
- RQ1Can gel wax serve as a stable and cost-effective medium for diagnostic ultrasound phantoms with consistent acoustic properties?
- RQ2How accurately can ultrasound systems measure distances and target diameters in a gel wax phantom compared to physical measurements?
- RQ3What is the long-term stability of the gel wax phantom in terms of dimensional and acoustic integrity over time?
- RQ4To what extent does the phantom support reliable assessment of image uniformity and geometric accuracy in ultrasound imaging?
- RQ5Can the phantom be reliably reproduced and used across different ultrasound systems for quality control?
Key findings
- The acoustic properties of gel wax were measured as: sound velocity (cus) = 1418 m/s, density (ρ) = 0.87 g/cm³, acoustic impedance (Z) = 1.23 MRayls, and attenuation coefficient = 0.88 dB/cm/MHz.
- The maximum error in distance measurement between US images and physical dimensions was 7.1%, indicating good geometric accuracy.
- The phantom volume decreased by only 1.8% over 62 weeks, demonstrating high long-term stability.
- The phantom enabled consistent assessment of image uniformity and target diameter, with results comparable to CT-based physical measurements.
- The use of stainless-steel discs and nylon filaments allowed for clear visualization and accurate measurement of hyperechoic targets in 2D ultrasound imaging.
Read this paper