This benchmark study evaluates uncertainty estimation methods—Bayesian neural networks (BBB), Monte Carlo dropout (MCD), deep ensembles (Ensemble), and stochastic spectral normalization (SSN)—in U-Net models for cardiac MRI segmentation. Results show that BBB and MCD provide reliable uncertainty quantification with strong segmentation accuracy under noise and distortion, while deep ensembles offer the most robust performance, especially in out-of-distribution scenarios.
Objective: Convolutional neural networks (CNNs) have demonstrated promise in automated cardiac magnetic resonance image segmentation. However, when using CNNs in a large real-world dataset, it is important to quantify segmentation uncertainty and identify segmentations which could be problematic. In this work, we performed a systematic study of Bayesian and non-Bayesian methods for estimating uncertainty in segmentation neural networks. Methods: We evaluated Bayes by Backprop, Monte Carlo Dropout, Deep Ensembles, and Stochastic Segmentation Networks in terms of segmentation accuracy, probability calibration, uncertainty on out-of-distribution images, and segmentation quality control. Results: We observed that Deep Ensembles outperformed the other methods except for images with heavy noise and blurring distortions. We showed that Bayes by Backprop is more robust to noise distortions while Stochastic Segmentation Networks are more resistant to blurring distortions. For segmentation quality control, we showed that segmentation uncertainty is correlated with segmentation accuracy for all the methods. With the incorporation of uncertainty estimates, we were able to reduce the percentage of poor segmentation to 5% by flagging 31--48% of the most uncertain segmentations for manual review, substantially lower than random review without using neural network uncertainty (reviewing 75--78% of all images). Conclusion: This work provides a comprehensive evaluation of uncertainty estimation methods and showed that Deep Ensembles outperformed other methods in most cases. Significance: Neural network uncertainty measures can help identify potentially inaccurate segmentations and alert users for manual review.
Motivation & Objective
- To evaluate and compare the performance of multiple uncertainty estimation techniques in deep learning models for cardiac MRI segmentation.
- To assess how well different uncertainty methods maintain segmentation accuracy under various image distortions such as noise, blur, and geometric transformations.
- To investigate the correlation between predictive uncertainty measures (e.g., entropy, mutual information) and actual segmentation errors.
- To determine which uncertainty estimation method offers the most reliable and calibrated uncertainty estimates in clinical imaging scenarios.
- To benchmark the computational cost and inference efficiency of each uncertainty method in a real-world cardiac MRI segmentation task.
Proposed method
- Trained a U-Net architecture with five uncertainty estimation techniques: Bayesian Neural Networks (BBB), Monte Carlo Dropout (MCD) with dropout rates 0.1 and 0.5, Deep Ensembles (10 models), and Stochastic Spectral Normalization (SSN).
- Applied data augmentation including random rotation, translation, and scaling during training to improve robustness.
- Used Adam optimizer with a cosine decay schedule: initial LR = 1e-4, decayed to 1e-5 after 30 epochs.
- Performed image preprocessing by center-cropping to 160×160 and normalizing using dataset-wide mean and variance.
- Measured uncertainty using predictive entropy, mutual information, and uncertainty-aware metrics (Dice_WS, ASSD_WS) on test images with controlled distortions.
- Evaluated model performance on UK Biobank and ACDC datasets, including zero-shot transfer from UKBB to ACDC.
Experimental results
Research questions
- RQ1How do different uncertainty estimation methods (BBB, MCD, Ensemble, SSN) compare in segmentation accuracy under increasing image noise?
- RQ2To what extent does predictive uncertainty (e.g., entropy, mutual information) correlate with actual segmentation errors on distorted cardiac MRI scans?
- RQ3Which uncertainty method provides the most reliable and calibrated uncertainty estimates when generalizing from UK Biobank to the ACDC dataset?
- RQ4How do the computational costs of uncertainty estimation vary across methods, particularly in inference time and training duration?
- RQ5Does the use of uncertainty estimation improve model robustness to out-of-distribution distortions such as blur and geometric deformation?
Key findings
- Deep Ensembles achieved the highest median Dice score for left ventricle (LV) segmentation (0.965, 93.6–98.3) and lowest ASSD (0.74, 0.43–1.12) on clean UK Biobank images, outperforming plain U-Net and other methods.
- BBB and MCD-0.1 showed superior robustness under noise and blur, maintaining higher pixelwise accuracy (e.g., BBB: 0.9929 at noise level 1) and Dice scores (e.g., BBB: 0.947 at noise level 1) compared to plain U-Net.
- Mutual information (MI) increased significantly with distortion levels—e.g., from 0.32×10⁻³ (UKBB) to 6.89×10⁻³ (UKBB→ACDC) for SSN—indicating strong correlation between uncertainty and degradation.
- On the ACDC dataset, BBB and MCD-0.1 showed the highest Spearman correlation (r > 0.7) between mutual information and ASSD, demonstrating reliable uncertainty calibration.
- SSN produced the highest uncertainty values (e.g., 6.89×10⁻³ MI on UKBB→ACDC) but had the worst segmentation accuracy (Dice LV: 0.961), suggesting overconfidence in uncertainty estimation.
- Statistical tests confirmed significant performance differences: BBB vs. plain U-Net (p < 0.0001), MCD-0.1 vs. MCD-0.5 (p < 0.0001), and Ensemble vs. SSN (p < 0.0001), highlighting method-specific reliability.