[Paper Review] Evaluating Power System Vulnerability to False Data Injection Attacks via Scalable Optimization
This paper proposes three scalable optimization algorithms to evaluate power system vulnerability to false data injection (FDI) attacks that induce line overflows. By reformulating the bi-level attack problem into mixed-integer linear programs and introducing bounds-based techniques, the methods efficiently compute worst-case attack impacts—even for large systems like the 2383-bus Polish grid—demonstrating that Algorithm 1 finds optimal attacks, while Algorithms 2 and 3 provide tight lower and upper bounds on vulnerability with significant computational gains.
Physical consequences to power systems of false data injection cyber-attacks are considered. Prior work has shown that the worst-case consequences of such an attack can be determined using a bi-level optimization problem, wherein an attack is chosen to maximize the physical power flow on a target line subsequent to re-dispatch. This problem can be solved as a mixed-integer linear program, but it is difficult to scale to large systems due to numerical challenges. Three new computationally efficient algorithms to solve this problem are presented. These algorithms provide lower and upper bounds on the system vulnerability measured as the maximum power flow subsequent to an attack. Using these techniques, vulnerability assessments are conducted for IEEE 118-bus system and Polish system with 2383 buses.
Motivation & Objective
- To address the scalability limitations of existing bi-level optimization methods for evaluating FDI attack impacts on large power systems.
- To develop computationally efficient algorithms that can assess worst-case physical consequences of FDI attacks, particularly line overflows, in systems with thousands of buses.
- To provide both optimal solutions and tight lower/upper bounds on attack severity for large-scale systems where exact solutions are intractable.
- To enable practical vulnerability assessment of real-world systems such as the IEEE 118-bus and 2383-bus Polish systems.
Proposed method
- Formulates the FDI attack problem as a bi-level optimization: the attacker maximizes post-re-dispatch power flow on a target line, while the system operator solves an optimal power flow (OPF) to balance the system.
- Converts the bi-level problem into a single-level mixed-integer linear program (MILP) using Karush-Kuhn-Tucker (KKT) conditions and reformulates non-convex complementary slackness as mixed-integer constraints.
- Proposes Algorithm 1 to reduce binary variables and line thermal limit constraints, enabling exact optimal solutions for smaller systems.
- Introduces Algorithm 2 to further reduce generation limit constraints and binary variables at the cost of optimality, yielding a lower bound on vulnerability.
- Develops Algorithm 3 using linear programming to compute both lower and upper bounds on the maximum power flow by maximizing the difference between cyber and physical power flows.
- Employs GUROBI as the solver and MATPOWER for power flow modeling, testing all algorithms on IEEE 118-bus and 2383-bus Polish systems.
Experimental results
Research questions
- RQ1Can the worst-case FDI attack causing line overflow be efficiently computed in large power systems using scalable optimization?
- RQ2How do the proposed algorithms compare in terms of computational efficiency and solution quality for large-scale systems?
- RQ3To what extent do the lower and upper bounds from Algorithms 2 and 3 approximate the true worst-case attack impact?
- RQ4Under what conditions do the bounds from Algorithm 3 tightly bracket the optimal solution?
- RQ5Can the proposed methods be applied to real-world systems with thousands of buses, such as the Polish 2383-bus system?
Key findings
- Algorithm 1 successfully computes the optimal worst-case FDI attack for the IEEE 118-bus system, achieving exact solutions with reduced binary variables and constraints.
- For the 2383-bus Polish system, Algorithm 1 does not converge in a reasonable time, indicating scalability limits of the exact approach.
- Algorithm 2 provides a feasible attack solution that results in significant line overflow, with tighter lower bounds than Algorithm 3 for some lines in the Polish system.
- Algorithm 3 produces both lower and upper bounds on the maximum power flow, with the bounds being tight (i.e., equal) for line 292 in the Polish system across $N_1 \in [0.1, 1.6]$, indicating optimal solutions were found.
- For target line 141 in the IEEE 118-bus system, all three algorithms achieve the same optimal solution, confirming the effectiveness of the bounds approach.
- The computational time of Algorithm 3 is significantly lower than Algorithms 1 and 2, making it the most efficient method for large-scale vulnerability assessment.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.