TL;DR

This study evaluates the data quality of SMI's eye-tracking HTC Vive HMD using a random saccade task, introducing a non-parametric spatial precision measure based on median absolute deviation (MAD). It finds the ET-HMD outperforms the EyeLink 1000 in spatial accuracy and linearity fit, though both show similar precision; the ET-HMD exhibits quadratic crosstalk, and binocular signals are low-pass filtered versions of monocular signals, limiting high-frequency saccade analysis.

ABSTRACT

We evaluated the data quality of SMI's tethered eye-tracking head-mounted display based on the HTC Vive (ET-HMD) during a random saccade task. We measured spatial accuracy, spatial precision, temporal precision, linearity, and crosstalk. We proposed the use of a non-parametric spatial precision measure based on the median absolute deviation (MAD). Our linearity analysis considered both the slope and adjusted R-squared of a best-fitting line. We were the first to test for a quadratic component to crosstalk. We prepended a calibration task to the random saccade task and evaluated 2 methods to employ this user-supplied calibration. For this, we used a unique binning approach to choose samples to be included in the recalibration analyses. We compared our quality measures between the ET-HMD and our EyeLink 1000 (SR-Research, Ottawa, Ontario, CA). We found that the ET-HMD had significantly better spatial accuracy and linearity fit than our EyeLink, but both devices had similar spatial precision and linearity slope. We also found that, while the EyeLink had no significant crosstalk, the ET-HMD generally exhibited quadratic crosstalk. Fourier analysis revealed that the binocular signal was a low-pass filtered version of the monocular signal. Such filtering resulted in the binocular signal being useless for the study of high-frequency components such as saccade dynamics.

Motivation & Objective

  • To assess the data quality of SMI's tethered eye-tracking HTC Vive HMD (ET-HMD) in a virtual reality environment.
  • To compare the ET-HMD's performance against the established EyeLink 1000 in key metrics: spatial accuracy, precision, temporal precision, linearity, and crosstalk.
  • To introduce and validate a non-parametric spatial precision measure using median absolute deviation (MAD) for improved robustness.
  • To investigate the impact of user-supplied calibration on data quality using a novel binning approach for recalibration analysis.
  • To analyze binocular signal degradation, revealing low-pass filtering effects that impair high-frequency saccade detection.

Proposed method

  • Conducted a random saccade task to evaluate spatial accuracy, precision, temporal precision, linearity, and crosstalk.
  • Proposed a non-parametric spatial precision metric based on median absolute deviation (MAD) to reduce sensitivity to outliers.
  • Performed linearity analysis using both slope and adjusted R-squared of the best-fitting line to assess calibration quality.
  • Tested for quadratic components in crosstalk, a novel approach not previously reported.
  • Used a unique binning strategy to select samples for recalibration analysis after a user-supplied calibration task.
  • Applied Fourier analysis to compare monocular and binocular eye movement signals, revealing signal filtering effects.

Experimental results

Research questions

  • RQ1How does the spatial accuracy of the SMI ET-HMD compare to the EyeLink 1000 in a VR environment?
  • RQ2To what extent does the ET-HMD exhibit crosstalk, and does it include a quadratic component?
  • RQ3How effective is a user-supplied calibration when combined with a novel binning approach for recalibration?
  • RQ4How does the binocular eye movement signal compare to the monocular signal in terms of frequency response?
  • RQ5What is the impact of signal filtering on the study of high-frequency eye movement dynamics like saccades?

Key findings

  • The ET-HMD demonstrated significantly better spatial accuracy than the EyeLink 1000, with a p-value < 0.05 indicating statistical significance.
  • The ET-HMD showed a superior linearity fit (adjusted R-squared) compared to the EyeLink 1000, though both devices had similar linearity slopes.
  • Both the ET-HMD and EyeLink 1000 exhibited comparable levels of spatial precision, as measured by the proposed MAD-based metric.
  • The ET-HMD exhibited significant quadratic crosstalk, a phenomenon not observed in the EyeLink 1000.
  • Fourier analysis revealed that the binocular signal was a low-pass filtered version of the monocular signal, degrading high-frequency components.
  • As a result, the binocular signal was deemed unsuitable for studying high-frequency eye movement dynamics such as saccade onset and velocity.