Skip to main content
QUICK REVIEW

[Paper Review] Evaluation of distortion correction methods in diffusion MRI of the spinal cord

Haykel Snoussi, Julien Cohen‐Adad|arXiv (Cornell University)|Aug 9, 2021
Advanced Neuroimaging Techniques and ApplicationsMedicine17 references9 citations
TL;DR

This study evaluates four distortion correction methods—HySCO, Block-Matching, TOPUP, and Voss—using reversed gradient polarity in spinal cord diffusion MRI at 3T. Using geometric metrics like angular concentration of diffusion directions and cross-correlation with anatomical images, HySCO demonstrated superior correction performance, significantly improving alignment with the spinal cord centerline and image fidelity, particularly at the superior and inferior ends of the acquisition window.

ABSTRACT

Background: Magnetic field inhomogeneities generate important geometric distortions in reconstructed echo-planar images. Various procedures were proposed for correcting these distortions on brain images; yet, few neuroimaging studies tailored and incorporated the use of these techniques in spinal cord diffusion MRI. Purpose: We present a comparative evaluation of distortion correction methods that use the reversed gradient polarity technique on spinal cord. We propose novel geometric metrics to measure the alignment of the reconstructed diffusion model with the apparent centerline of the spinal cord. Subjects: 95 subjects, among which 29 healthy controls and 66 multiple sclerosis patients. Assessment: Geometric distortions were corrected using 4 state-of-the-art methods. We measured the alignment of the principal direction of diffusion with the apparent centerline of the spine after correction and the correlation with the reference anatomical image. Results are computed per vertebral level, to evaluate the impact on different portions of the spine. Besides, subjective evaluation of the quality of the correction of healthy subjects images was performed by three expert raters. Results: As a result of distortion correction, the diffusion directions are better aligned locally with the centerline, in particular at both ends of the acquisition window. The cross-correlation with anatomical image is also improved by Hyperelastic Susceptibility Artefact Correction (HySCO) and block-matching. The subjective evaluation for HySCO is significantly better (p < 0.05) than for Block-Matching; TOPUP performs significantly worse than the three other methods. Conclusion: Correction based on HySCO provide best results among the selected methods.

Motivation & Objective

  • To evaluate and compare state-of-the-art distortion correction methods for spinal cord diffusion MRI using reversed gradient polarity.
  • To address geometric distortions caused by B0 inhomogeneities, which are especially severe in the spinal cord due to its small size and complex surrounding tissues.
  • To develop and apply novel geometric metrics to quantify alignment between diffusion direction and the apparent spinal cord centerline.
  • To perform a subjective evaluation by expert raters to assess visual quality of corrected images.
  • To determine which method provides the most accurate and reliable distortion correction across different vertebral levels.

Proposed method

  • Acquired 3T diffusion-weighted echo-planar imaging (EPI) data from 95 subjects (29 healthy, 66 multiple sclerosis patients) with b-value 900 s/mm² and 30 diffusion directions.
  • Applied four distortion correction methods: Hyperelastic Susceptibility Artefact Correction (HySCO), Block-Matching, TOPUP, and Voss, all based on reversed gradient polarity.
  • Proposed a novel geometric metric—angular concentration of diffusion directions (ACD)—to measure alignment with the apparent spinal cord centerline.
  • Used cross-correlation and mutual information between corrected diffusion data and T2-weighted anatomical images as additional fidelity metrics.
  • Performed voxel-wise segmentation of spinal cord volume and computed metrics per vertebral level (C1–T2) to assess regional variation in correction performance.
  • Conducted a subjective evaluation using a web interface with three expert raters ranking image quality across the four methods, modeled with a logistic regression including rater random effects.

Experimental results

Research questions

  • RQ1Which distortion correction method most effectively realigns the principal diffusion direction with the apparent spinal cord centerline across vertebral levels?
  • RQ2How do the different correction methods affect image fidelity as measured by cross-correlation and mutual information with T2-weighted anatomical images?
  • RQ3Does the performance of distortion correction vary significantly across different regions of the spinal cord (e.g., cervical vs. thoracic vs. brainstem)?
  • RQ4How does subjective image quality ranking by expert raters compare with objective geometric and intensity-based metrics?
  • RQ5Is there a statistically significant difference in correction performance between HySCO, Block-Matching, TOPUP, and Voss methods?

Key findings

  • HySCO significantly improved angular concentration of diffusion directions (ACD) compared to uncorrected data (p < 10⁻³) and other methods, especially at the brainstem and C1 levels.
  • HySCO achieved the highest cross-correlation with T2-weighted anatomical images (mean 0.242), with a p-value of 2.1×10⁻⁴ compared to uncorrected data, indicating superior image alignment.
  • Subjective evaluation showed HySCO was ranked significantly better than Block-Matching (p < 0.05), and TOPUP performed significantly worse than all other methods.
  • Block-Matching and HySCO showed significant improvement in cross-correlation (p = 0.029 and p = 2.1×10⁻⁴, respectively), while TOPUP and Voss did not reach significance.
  • Mutual information analysis confirmed HySCO’s superiority (p = 4.1×10⁻¹⁴) and Block-Matching’s strong performance (p = 10⁻⁵), indicating better structural similarity.
  • Significant differences in spinal cord volume were observed across correction methods (p < 0.05), with HySCO and Block-Matching showing more consistent and accurate segmentation.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.