Skip to main content
QUICK REVIEW

[Paper Review] Evaluation of Various Open-Set Medical Imaging Tasks with Deep Neural Networks

Zongyuan Ge, Xin Wang|arXiv (Cornell University)|Oct 21, 2021
Artificial Intelligence in Healthcare and EducationMedicine38 references4 citations
TL;DR

This paper evaluates state-of-the-art open-set recognition methods—ODIN, MC Dropout, OpenMax, and OLTR—on medical imaging tasks across self-domain, similar-domain, and different-domain scenarios. Using ImageNet-pretrained models on dermatology, ophthalmology, and radiology datasets, it finds that open-set focused models (especially OLTR) outperform uncertainty-based methods in detecting unknowns, with OLTR showing the best balance of accuracy, calibration, and inference speed for clinical deployment.

ABSTRACT

The current generation of deep neural networks has achieved close-to-human results on "closed-set" image recognition; that is, the classes being evaluated overlap with the training classes. Many recent methods attempt to address the importance of the unknown, which are termed "open-set" recognition algorithms, try to reject unknown classes as well as maintain high recognition accuracy on known classes. However, it is still unclear how different general domain-trained open-set methods from ImageNet would perform on a different but more specific domain, such as the medical domain. Without principled and formal evaluations to measure the effectiveness of those general open-set methods, artificial intelligence (AI)-based medical diagnostics would experience ineffective adoption and increased risks of bad decision making. In this paper, we conduct rigorous evaluations amongst state-of-the-art open-set methods, exploring different open-set scenarios from "similar-domain" to "different-domain" scenarios and comparing them on various general and medical domain datasets. We summarise the results and core ideas and explain how the models react to various degrees of openness and different distributions of open classes. We show the main difference between general domain-trained and medical domain-trained open-set models with our quantitative and qualitative analysis of the results. We also identify aspects of model robustness in real clinical workflow usage according to confidence calibration and the inference efficiency.

Motivation & Objective

  • To assess the effectiveness of general-domain open-set recognition methods (trained on ImageNet) in medical imaging tasks where domain shift exists.
  • To compare uncertainty-based methods (ODIN, MC Dropout) with open-set focused models (OpenMax, OLTR) in detecting out-of-distribution medical conditions.
  • To evaluate model robustness in real clinical workflows through confidence calibration and inference efficiency.
  • To provide publicly available code, logits, and models to establish a benchmark for future medical open-set research.

Proposed method

  • Fine-tuned ImageNet-pretrained models (ResNet-50) on three medical datasets: dermatology (ISIC), ophthalmology (APTOS), and radiology (NIH ChestX-ray).
  • Applied temperature scaling to calibrate model probabilities and improve confidence calibration for medical decision-making.
  • Evaluated four open-set methods: ODIN (input perturbation + temperature scaling), MC Dropout (Bayesian uncertainty estimation), OpenMax (open-set risk modeling), and OLTR (open-set loss with representation learning).
  • Conducted three open-set scenarios: self-domain (same domain as training), similar-domain (e.g., dermatology to ophthalmology), and different-domain (e.g., ImageNet to medical).
  • Measured performance using known-class accuracy, AUC for unknown detection, and inference speed on a GTX 1080Ti GPU.
  • Used confidence calibration metrics (e.g., ECE) and reported inference times to assess clinical feasibility.

Experimental results

Research questions

  • RQ1How do general-domain open-set methods perform when transferred to medical imaging domains with domain shift?
  • RQ2Which open-set method—uncertainty-based or open-set focused—better detects unknown medical conditions across varying degrees of domain similarity?
  • RQ3How does confidence calibration affect the reliability of open-set predictions in clinical decision support systems?
  • RQ4What is the inference efficiency of different open-set methods, and which is most suitable for real-time clinical deployment?
  • RQ5To what extent does domain similarity between source and target datasets influence open-set recognition performance?

Key findings

  • OLTR outperformed all other methods in detecting unknowns across all three open-set scenarios, especially in similar- and different-domain tasks.
  • Open-set focused models (OpenMax, OLTR) significantly outperformed uncertainty-based methods (ODIN, MC Dropout) in unknown detection, particularly under domain shift.
  • MC Dropout had the slowest inference speed—20× slower than ODIN—due to its Monte Carlo sampling nature, limiting real-time use.
  • ODIN achieved the fastest inference speed (112.3 ms on GTX 1080Ti), but had poor unknown detection performance on medical data.
  • OLTR showed the best trade-off between detection performance, calibration, and inference speed, making it most suitable for clinical deployment.
  • Confidence calibration via temperature scaling significantly improved model reliability, especially for OLTR and OpenMax, reducing miscalibration in medical predictions.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.