Skip to main content
QUICK REVIEW

[Paper Review] Evidence of electric breakdown induced by bubbles in liquid argon

F. Bay, C. Cantini|arXiv (Cornell University)|Jan 13, 2014
Power Transformer Diagnostics and InsulationEngineering5 citations
TL;DR

This study investigates electric breakdown in liquid argon under high voltage, demonstrating that bubble formation drastically reduces dielectric strength—down to 40 kV/cm—compared to 100 kV/cm in stable, non-boiling liquid argon. The results provide critical evidence that bubbles act as preferential breakdown pathways due to argon gas's lower dielectric rigidity, informing design for large-scale liquid argon detectors like GLACIER for neutrino physics.

ABSTRACT

We report on the results of a high voltage test in liquid argon in order to measure its dielectric rigidity. Under stable conditions and below the boiling point, liquid argon was found to sustain a uniform electric field of 100 kV/cm, applied in a region of 20 cm$^2$ area across 1 cm thick gap. When the liquid is boiling, breakdowns may occur at electric fields as low as 40 kV/cm. This test is one of the R&D efforts towards the Giant Liquid Argon Charge Imaging ExpeRiment (GLACIER) as proposed Liquid Argon Time Projection Chamber (LAr TPC) for the LBNO observatory for neutrino physics, astrophysics and nucleon decay searches.

Motivation & Objective

  • To measure the dielectric rigidity of liquid argon under high voltage conditions for application in large-scale neutrino detectors.
  • To investigate the impact of boiling and bubble formation on electric breakdown thresholds in liquid argon.
  • To validate the performance of a high-voltage test setup with uniform field geometry for future detector R&D.
  • To support the development of the GLACIER liquid argon time projection chamber for the LBNO experiment.
  • To assess the feasibility of double-phase operation (liquid-vapor) for signal amplification in charge imaging detectors.

Proposed method

  • A high-voltage test setup with a 20 cm² uniform electric field region was constructed using Rogowski-profile electrodes in a vacuum-insulated dewar.
  • Liquid argon was purified via molecular sieves and copper cartridges to minimize impurities and maintain low residual pressure (<10⁻⁴ mbar).
  • The system applied up to -100 kV across a 1 cm gap, generating a field of 100 kV/cm in non-boiling liquid argon.
  • Voltage was ramped up over 20 seconds to test stability and monitor for discharges using a high-voltage coaxial cable with inductive coupling to an oscilloscope.
  • Boiling was induced by reducing pressure via liquid nitrogen flow through a serpentine heat exchanger, allowing controlled bubble formation.
  • Breakdown events were monitored visually through a viewport and electrically via discharge current detection, with field strength adjusted by pressure control.

Experimental results

Research questions

  • RQ1What is the maximum electric field strength that liquid argon can sustain without breakdown under stable, non-boiling conditions?
  • RQ2How does the presence of bubbles in boiling liquid argon affect the breakdown threshold?
  • RQ3Can bubbles in liquid argon act as preferential channels for electrical breakdown due to the lower dielectric strength of argon gas?
  • RQ4What is the relationship between pressure-induced boiling and the onset of electric breakdown in liquid argon?
  • RQ5How does the dielectric rigidity of liquid argon vary with temperature, pressure, and phase state in a controlled high-voltage environment?

Key findings

  • Liquid argon sustained a uniform electric field of 100 kV/cm without breakdown when below its boiling point, indicating a dielectric rigidity exceeding 100 kV/cm.
  • In boiling liquid argon, electric breakdown occurred at fields as low as 40 kV/cm, significantly lower than in stable liquid argon.
  • Breakdown events were strongly correlated with visible bubble formation, suggesting bubbles initiate or facilitate discharge paths.
  • At 930 mbar, breakdowns occurred at 70 kV/cm, and at pressures below 880 mbar, breakdowns occurred at 40 kV/cm, indicating a pressure-dependent threshold.
  • The observed reduction in breakdown strength is attributed to the lower dielectric rigidity of argon gas compared to liquid argon, with bubbles forming preferred discharge channels.
  • The system demonstrated stable operation for over 4 hours at -100 kV with repeated charging cycles, confirming the robustness of the setup under non-boiling conditions.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.