[Paper Review] Experimental Challenges of the European Strategy for Particle Physics
This paper addresses pileup mitigation in the HL-LHC era by developing precision timing detectors capable of sub-20 picosecond resolution in high-rate, high-radiation environments. It presents a deep-depleted APD/MicroMegas tracker design achieving ~21 ps timing jitter from Landau/Vavilov signal fluctuations, demonstrating a viable path to reduce pileup effects in ATLAS and CMS experiments through improved timing-based event reconstruction.
In planning for the Phase II upgrades of CMS and ATLAS major considerations are: 1)being able to deal with degradation of tracking and calorimetry up to the radiation doses to be expected with an integrated luminosity of 3000 $fb^{-1}$ and 2)maintaining physics performance at a pileup level of ~140. Here I report on work started within the context of the CMS Forward Calorimetry Task Force and continuing in an expanded CERN RD52 R$&$D program integrating timing (i.e. measuring the time-of-arrival of physics objects) as a potential tool for pileup mitigation and ideas for Forward Calorimetry. For the past 4 years our group has focused on precision timing at the level of 10-20 picoseconds in an environment with rates of $~10^6-10^7$ Hz/$cm^2 $ as is appropriate for the future running of the LHC (HL-LHC era). A time resolution of 10-20 picoseconds is one of the few clear criteria for pileup mitigation at the LHC, since the interaction time of a bunch crossing has an rms of 170 picosec. While work on charged particle timing in other contexts (i.e. ALICE R$&$D) is starting to approach this precision, there have been essentially no technologies that can sustain performance at these rates. I will present results on a tracker we developed within the DOE Advanced Detector R$&$D program which is now meeting these requirements. I will also review some results from Calorimeter Projects developed within our group (PHENIX EMCAL and ATLAS ZDC) which achieved calorimeter timing precision< 100 picoseconds.
Motivation & Objective
- Address the challenge of event pileup at HL-LHC, where instantaneous pileup levels may reach 140, degrading physics analysis performance.
- Develop timing-based tools to mitigate pileup, particularly for reconstructing forward proton remnants and reducing mis-association of jets.
- Achieve sub-20 picosecond timing resolution in high-rate, high-radiation environments typical of the HL-LHC (10^6–10^7 Hz/cm²).
- Optimize detector design and electronics for minimal timing jitter, focusing on signal formation and noise suppression.
- Integrate timing capabilities into future upgrades of CMS and ATLAS, particularly in forward calorimetry and tracking systems.
Proposed method
- Design and prototype a deep-depleted APD with a 60 µm depletion region, where only the last 40 µm supports saturated electric field for fast signal formation.
- Use a MicroMegas mesh as an external capacitor plate to reduce time walk and position-dependent timing jitter.
- Model charge drift and signal induction using Ramo’s theorem, focusing on electron drift at ~10 ps/µm toward the amplification region.
- Simulate signal formation by dividing the 40 µm region into 40 layers of 1 µm thickness, each with Landau/Vavilov-distributed energy deposition.
- Apply constant fraction timing algorithms to measure mean time of arrival and assess jitter from non-Gaussian signal distributions.
- Conduct beam tests with femtosecond laser pulses to validate timing performance and optimize pre-amplifier matching to detector capacitance (60 pF).
Experimental results
Research questions
- RQ1Can sub-20 picosecond timing resolution be achieved in silicon detectors under HL-LHC radiation and rate conditions?
- RQ2To what extent does Landau/Vavilov fluctuation in charge deposition contribute to timing jitter in thin silicon detectors?
- RQ3How effective is the MicroMegas mesh as an external capacitor in reducing position-dependent timing walk in deep-depleted APDs?
- RQ4What is the impact of detector thickness and gain on timing jitter, and how can optimal trade-offs be made?
- RQ5Can timing-based reconstruction reduce pileup effects in Higgs boson and vector boson fusion analyses by a factor of 10?
Key findings
- The deep-depleted APD/MicroMegas design reduces timing jitter from >0.6 ns to ~21 ps, primarily due to suppression of position-dependent time walk.
- Timing jitter from Landau/Vavilov fluctuations in 40 µm thick silicon layers is quantified at approximately 21 picoseconds for minimum ionizing particles.
- The jitter decreases proportionally with reduced depletion depth, indicating a path to further improvement through thinner, high-gain designs.
- Signal formation and noise from leakage current remain below the fundamental limits observed in current measurements, indicating headroom for further optimization.
- Beam tests are underway to validate sub-20 ps timing resolution with improved electronics (SAMPIC, DRS5, HPTDC) and noise suppression.
- Calorimeter timing performance, particularly from ATLAS ZDC data, shows promise for integration into future timing-based pileup mitigation strategies.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.