[Paper Review] Experimental determination and modelling of volume shrinkage in curing thermosets
This study presents a novel real-time experimental setup based on Archimedes' principle to measure volume shrinkage during the curing of epoxy-based thermosets. By combining strain gauges and capacitive sensors with environmental compensation, the method enables precise, simultaneous detection of absolute density and small thermochemical volume changes, validated through phenomenological modeling of curing kinetics and shrinkage, with key parameters identified via nonlinear optimization.
This work deals with the characterisation and modelling of the curing process and its associated volume changes of an epoxy based thermoset resin. Measurements from differential scanning calorimetry (DSC) define the progress of the chemical reaction. The related thermochemical volume changes are recorded by an especially constructed experimental setup based on Archimedes principle. Information on measuring procedure and data processing are provided. This includes investigations on compensation of environmental influences, long-term stability and resolution. With the aim of simulating the adhesives curing process, constitutive models representing the reaction kinetics and thermochemical volume changes are presented and the model parameters are identified.
Motivation & Objective
- To develop a real-time, high-resolution method for measuring volume and density changes during the curing of thermoset adhesives.
- To address the challenge of accurately capturing small, thermochemically induced volume changes in liquid-to-solid transitioning materials.
- To model the curing process using differential scanning calorimetry (DSC) data and develop a constitutive model for volume shrinkage.
- To validate the experimental measurements against a phenomenological model of reaction kinetics and isotropic volume changes.
- To enable accurate simulation of curing-induced deformations and residual stresses in lightweight composite manufacturing.
Proposed method
- An experimental setup based on Archimedes' principle was designed to measure buoyancy changes during curing.
- Two sensor systems—strain gauges and capacitive sensors—were combined to measure both absolute volume and small volume changes with high resolution.
- Environmental influences were compensated using a dummy signal to ensure measurement stability.
- The system was calibrated and tested for long-term stability, resolution, and repeatability across multiple temperature levels.
- Differential scanning calorimetry (DSC) was used to determine the degree of cure over time.
- A phenomenological model was developed using Eq. (15) to describe temperature- and cure-dependent density changes, with parameters identified via nonlinear least squares optimization.
Experimental results
Research questions
- RQ1How can real-time, high-resolution volume shrinkage be measured during the curing of epoxy-based thermosets?
- RQ2What is the relationship between the degree of cure and the resulting thermochemical volume change in a curing thermoset?
- RQ3How can environmental and mechanical disturbances be effectively compensated in buoyancy-based volume measurements?
- RQ4To what extent does the curing reaction progress depend on temperature, and how does this affect final shrinkage?
- RQ5Can a phenomenological model accurately predict the evolution of density and volume shrinkage during curing based on DSC data?
Key findings
- The experimental setup achieved high resolution and long-term stability, enabling reliable real-time measurement of small volume changes during curing.
- The measured density evolution showed non-linear behavior due to diffusion control at elevated temperatures, with shrinkage ceasing before full conversion at temperatures above the glass transition.
- The model parameter βq, representing maximum volumetric chemical shrinkage, was identified as -0.053, indicating significant shrinkage potential.
- The simulation results based on Eq. (15) closely matched experimental data across different time-temperature regimes, validating the model's predictive capability.
- The combination of strain gauges and capacitive sensors allowed simultaneous detection of absolute density and small changes with improved accuracy.
- The use of a dummy signal for environmental compensation significantly enhanced measurement reliability and reduced drift.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.