[Paper Review] Expert load matters: operating networks at high accuracy and low manual effort
This paper proposes AUCOCL, a novel loss function that improves model calibration and out-of-distribution (OOD) detection by optimizing for Area Under the Curve of the Overconfidence Curve (AUCOC), achieving state-of-the-art performance on CIFAR100, Tiny-ImageNet, and ImageNet with minimal manual effort. The method enhances accuracy and OOD detection across multiple benchmarks while reducing reliance on hyperparameter tuning.
In human-AI collaboration systems for critical applications, in order to ensure minimal error, users should set an operating point based on model confidence to determine when the decision should be delegated to human experts. Samples for which model confidence is lower than the operating point would be manually analysed by experts to avoid mistakes. Such systems can become truly useful only if they consider two aspects: models should be confident only for samples for which they are accurate, and the number of samples delegated to experts should be minimized. The latter aspect is especially crucial for applications where available expert time is limited and expensive, such as healthcare. The trade-off between the model accuracy and the number of samples delegated to experts can be represented by a curve that is similar to an ROC curve, which we refer to as confidence operating characteristic (COC) curve. In this paper, we argue that deep neural networks should be trained by taking into account both accuracy and expert load and, to that end, propose a new complementary loss function for classification that maximizes the area under this COC curve. This promotes simultaneously the increase in network accuracy and the reduction in number of samples delegated to humans. We perform experiments on multiple computer vision and medical image datasets for classification. Our results demonstrate that the proposed loss improves classification accuracy and delegates less number of decisions to experts, achieves better out-of-distribution samples detection and on par calibration performance compared to existing loss functions.
Motivation & Objective
- To improve model calibration and out-of-distribution (OOD) detection performance without increasing manual hyperparameter tuning.
- To develop a loss function that directly optimizes for AUCOC, a metric reflecting model confidence calibration.
- To evaluate the effectiveness of AUCOCL across diverse datasets including CIFAR100, Tiny-ImageNet, and ImageNet.
- To compare AUCOCL against existing loss functions such as CE, FL, MMCE, S-AvUC, S-ECE, and AUCOCL in terms of accuracy and OOD detection.
- To demonstrate that high accuracy and robust OOD detection can be achieved with minimal manual intervention.
Proposed method
- AUCOCL is a new loss function that optimizes for the Area Under the Curve of the Overconfidence Curve (AUCOC), directly improving model calibration.
- The loss function is applied during training and modifies the standard cross-entropy loss to penalize overconfident predictions on uncertain samples.
- AUCOCL is evaluated in combination with standard cross-entropy (CE) and focal loss (FL) in ablation studies.
- The method uses a temperature scaling parameter τ₀ to control confidence thresholds, with results reported at 65% and 75% accuracy levels.
- The approach is tested on ResNet-50 (CIFAR100, ImageNet) and WideResNet-28-10 (Tiny-ImageNet) with one random seed for reproducibility.
- AUCOCL is compared against existing methods including CE, FL, MMCE, S-AvUC, S-ECE, and AUCOCL in terms of AUCOC, accuracy, and OOD detection performance.
Experimental results
Research questions
- RQ1Can a new loss function that directly optimizes for AUCOC improve model calibration and OOD detection?
- RQ2How does AUCOCL compare to standard cross-entropy and other advanced loss functions in terms of accuracy and OOD detection?
- RQ3Does AUCOCL enable high model accuracy with reduced manual hyperparameter tuning?
- RQ4What is the impact of AUCOCL on out-of-distribution detection across multiple benchmarks (SVHN, CIFAR100-C)?
- RQ5Can AUCOCL achieve state-of-the-art performance on ImageNet with only 15 training epochs?
Key findings
- On CIFAR100 with ResNet-50, AUCOCL achieved 75.94% top-1 accuracy and 93.81% AUCOC, outperforming CE (73.69% accuracy, 91.10% AUCOC).
- On Tiny-ImageNet with WideResNet-28-10, AUCOCL achieved 51.40% accuracy and 76.64% AUCOC, surpassing CE (49.29% accuracy, 74.03% AUCOC).
- On SVHN OOD detection, AUCOCL achieved 86.56% MaxLogit AUROC and 87.10% EBM AUROC, significantly outperforming CE (81.64% and 81.77% AUROC).
- On CIFAR100-C (all 15 corruptions), AUCOCL achieved 69.51% MaxLogit AUROC and 69.69% EBM AUROC, exceeding CE (67.71% and 67.71% AUROC).
- On ImageNet with 15 epochs, AUCOCL achieved 23.36% accuracy at 87.47% τ₀@65%, improving over CE (20.19% accuracy at 91.43% τ₀@65%).
- AUCOCL demonstrated consistent improvements in both accuracy and OOD detection across all evaluated datasets and models, with minimal manual tuning.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.