Skip to main content
QUICK REVIEW

[Paper Review] Explainable AI based Glaucoma Detection using Transfer Learning and LIME

Touhidul Islam Chayan, Anita Islam|arXiv (Cornell University)|Oct 7, 2022
Retinal Imaging and AnalysisMedicine8 citations
TL;DR

This paper proposes a transfer learning-based glaucoma detection model using ResNet50, achieving 94.71% validation accuracy, and integrates LIME for interpretability to address the black-box nature of deep learning in medical imaging. The system enhances clinical trust by visualizing key features influencing predictions on fundus images.

ABSTRACT

Glaucoma is the second driving reason for partial or complete blindness among all the visual deficiencies which mainly occurs because of excessive pressure in the eye due to anxiety or depression which damages the optic nerve and creates complications in vision. Traditional glaucoma screening is a time-consuming process that necessitates the medical professionals' constant attention, and even so time to time due to the time constrains and pressure they fail to classify correctly that leads to wrong treatment. Numerous efforts have been made to automate the entire glaucoma classification procedure however, these existing models in general have a black box characteristics that prevents users from understanding the key reasons behind the prediction and thus medical practitioners generally can not rely on these system. In this article after comparing with various pre-trained models, we propose a transfer learning model that is able to classify Glaucoma with 94.71\% accuracy. In addition, we have utilized Local Interpretable Model-Agnostic Explanations(LIME) that introduces explainability in our system. This improvement enables medical professionals obtain important and comprehensive information that aid them in making judgments. It also lessen the opacity and fragility of the traditional deep learning models.

Motivation & Objective

  • Automate glaucoma classification to reduce reliance on time-consuming manual screening.
  • Provide medical professionals with interpretable insights into model predictions to increase trust in AI-based diagnostics.
  • Reduce the workload and human error in glaucoma detection by replacing manual assessment with an explainable AI system.
  • Improve early detection of glaucoma, especially open-angle glaucoma, to prevent irreversible vision loss.
  • Address the opacity of deep learning models by integrating Local Interpretable Model-Agnostic Explanations (LIME) for feature-level interpretability.

Proposed method

  • Fine-tuned multiple pre-trained CNN models—VGG-16, VGG-19, DenseNet121, InceptionV3, and ResNet50—on a benchmark glaucoma fundus image dataset.
  • Used transfer learning with ImageNet-pretrained weights to adapt models for glaucoma classification with a 50-epoch training schedule.
  • Employed the Adam optimizer with a base learning rate of 1e-5 to optimize model training.
  • Applied LIME to generate local, instance-level explanations by perturbing input images and analyzing feature contributions to predictions.
  • Generated visual saliency maps highlighting regions of fundus images most influential in classification decisions.
  • Evaluated model performance using accuracy, loss, and misclassification rates across both glaucoma and non-glaucoma classes.

Experimental results

Research questions

  • RQ1Which pre-trained deep learning model performs best for glaucoma detection on fundus images when using transfer learning?
  • RQ2How does LIME enhance interpretability in a deep learning-based glaucoma detection system?
  • RQ3To what extent does the integration of LIME improve clinical trust in AI-driven glaucoma diagnosis?
  • RQ4What is the impact of model architecture on generalization and overfitting in glaucoma classification tasks?
  • RQ5How do misclassified images differ in feature importance patterns compared to correctly classified ones?

Key findings

  • ResNet50 achieved the highest validation accuracy of 94.71%, outperforming VGG-19 (93.31%), VGG-16 (88.63%), InceptionV3 (86.42%), and DenseNet121 (86.81%).
  • ResNet50 recorded zero misclassifications on the validation set, with 100% accuracy for both glaucoma and non-glaucoma classes.
  • VGG-19 showed strong performance with 93.31% validation accuracy and only 3 misclassified cases in the test set.
  • LIME successfully generated localized, human-interpretable explanations by highlighting regions of fundus images that contributed most to predictions.
  • The model’s predictions were visually explainable, with LIME identifying optic disc and cup regions as key discriminative features for glaucoma detection.
  • The integration of LIME significantly reduced model opacity, enabling clinicians to validate predictions based on anatomical landmarks in fundus images.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.