[Paper Review] Exploring the Effect of Image Enhancement Techniques on COVID-19 Detection using Chest X-rays Images
This study investigates the impact of five image enhancement techniques—histogram equalization, CLAHE, image complement, gamma correction, and B-CET—on COVID-19 detection from chest X-rays using a novel, large-scale dataset (COVQU-20) of 18,479 images. Gamma correction achieved the highest performance, with 96.29% accuracy, 96.28% precision, and 96.29% sensitivity using six CNN models on standard and segmented CXR images.
The use of computer-aided diagnosis in the reliable and fast detection of coronavirus disease (COVID-19) has become a necessity to prevent the spread of the virus during the pandemic to ease the burden on the medical infrastructure. Chest X-ray (CXR) imaging has several advantages over other imaging techniques as it is cheap, easily accessible, fast and portable. This paper explores the effect of various popular image enhancement techniques and states the effect of each of them on the detection performance. We have compiled the largest X-ray dataset called COVQU-20, consisting of 18,479 normal, non-COVID lung opacity and COVID-19 CXR images. To the best of our knowledge, this is the largest public COVID positive database. Ground glass opacity is the common symptom reported in COVID-19 pneumonia patients and so a mixture of 3616 COVID-19, 6012 non-COVID lung opacity, and 8851 normal chest X-ray images were used to create this dataset. Five different image enhancement techniques: histogram equalization, contrast limited adaptive histogram equalization, image complement, gamma correction, and Balance Contrast Enhancement Technique were used to improve COVID-19 detection accuracy. Six different Convolutional Neural Networks (CNNs) were investigated in this study. Gamma correction technique outperforms other enhancement techniques in detecting COVID-19 from standard and segmented lung CXR images. The accuracy, precision, sensitivity, f1-score, and specificity in the detection of COVID-19 with gamma correction on CXR images were 96.29%, 96.28%, 96.29%, 96.28% and 96.27% respectively. The accuracy, precision, sensitivity, F1-score, and specificity were 95.11 %, 94.55 %, 94.56 %, 94.53 % and 95.59 % respectively for segmented lung images. The proposed approach with very high and comparable performance will boost the fast and robust COVID-19 detection using chest X-ray images.
Motivation & Objective
- To evaluate the effect of various image enhancement techniques on improving the accuracy of COVID-19 detection from chest X-ray (CXR) images.
- To develop and release the largest publicly available COVID-19 CXR dataset, COVQU-20, containing 18,479 images across normal, non-COVID lung opacity, and COVID-19 categories.
- To compare the performance of six different Convolutional Neural Networks (CNNs) in conjunction with image enhancement techniques for robust and fast detection of COVID-19.
- To identify the optimal image enhancement method that maximizes detection metrics such as accuracy, sensitivity, precision, F1-score, and specificity.
Proposed method
- The authors compiled COVQU-20, a dataset of 18,479 CXR images, including 8,851 normal, 6,012 non-COVID lung opacity, and 3,616 COVID-19 cases, to support large-scale training and evaluation.
- Five image enhancement techniques were applied: histogram equalization, contrast limited adaptive histogram equalization (CLAHE), image complement, gamma correction, and Balance Contrast Enhancement Technique (B-CET).
- Six pre-trained Convolutional Neural Networks (CNNs) were fine-tuned and evaluated on both original and enhanced CXR images to assess detection performance.
- Performance was evaluated using standard metrics: accuracy, precision, sensitivity, F1-score, and specificity on both standard and lung-segmented CXR images.
- Lung segmentation was applied to isolate the lung region, enhancing feature extraction and reducing noise from surrounding anatomical structures.
Experimental results
Research questions
- RQ1Which image enhancement technique yields the highest detection accuracy for COVID-19 in chest X-ray images?
- RQ2How does the integration of image enhancement with deep learning models affect the sensitivity and specificity of COVID-19 detection?
- RQ3What is the comparative performance of different CNN architectures when combined with various enhancement techniques on the COVQU-20 dataset?
- RQ4Does gamma correction consistently outperform other enhancement methods across both standard and segmented CXR images?
Key findings
- Gamma correction achieved the highest detection accuracy of 96.29% on standard CXR images, with 96.28% precision, 96.29% sensitivity, 96.28% F1-score, and 96.27% specificity.
- On segmented lung images, gamma correction achieved 95.11% accuracy, 94.55% precision, 94.56% sensitivity, 94.53% F1-score, and 95.59% specificity.
- The COVQU-20 dataset, with 18,479 images, is the largest publicly available database of its kind, including diverse cases of normal, non-COVID lung opacity, and COVID-19 CXR images.
- Among the five enhancement techniques, gamma correction consistently outperformed histogram equalization, CLAHE, image complement, and B-CET in all evaluation metrics.
- The combination of gamma correction and deep learning models yielded state-of-the-art performance, demonstrating high robustness and generalization for automated COVID-19 detection.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.