Skip to main content
QUICK REVIEW

[Paper Review] Fake It Right: Injecting Anatomical Logic into Synthetic Supervised Pre-training for Medical Segmentation

Jiaqi Tang, Mengyan Zheng|arXiv (Cornell University)|Mar 1, 2026
Advanced Neural Network ApplicationsComputer Science0 citations
TL;DR

The paper introduces Anatomy-Informed Synthetic Supervised Pre-training that combines formula-driven synthetic data with anatomical priors to pre-train 3D medical segmentation transformers, improving downstream performance on CT/MRI tasks without using real patient textures.

ABSTRACT

Vision Transformers (ViTs) excel in 3D medical segmentation but require massive annotated datasets. While Self-Supervised Learning (SSL) mitigates this using unlabeled data, it still faces strict privacy and logistical barriers. Formula-Driven Supervised Learning (FDSL) offers a privacy-preserving alternative by pre-training on synthetic mathematical primitives. However, a critical semantic gap limits its efficacy: generic shapes lack the morphological fidelity, fixed spatial layouts, and inter-organ relationships of real anatomy, preventing models from learning essential global structural priors. To bridge this gap, we propose an Anatomy-Informed Synthetic Supervised Pre-training framework unifying FDSL's infinite scalability with anatomical realism. We replace basic primitives with a lightweight shape bank with de-identified, label-only segmentation masks from 5 subjects. Furthermore, we introduce a structure-aware sequential placement strategy to govern the patch synthesis process. Instead of random placement, we enforce physiological plausibility using spatial anchors for correct localization and a topological graph to manage inter-organ interactions (e.g., preventing impossible overlaps). Extensive experiments on BTCV and MSD datasets demonstrate that our method significantly outperforms state-of-the-art FDSL baselines and SSL methods by 1.74\% and up to 1.66\%, while exhibiting a robust scaling effect where performance improves with increased synthetic data volume. This provides a data-efficient, privacy-compliant solution for medical segmentation. The code will be made publicly available upon acceptance.

Motivation & Objective

  • Motivate data-efficient, privacy-preserving pre-training for 3D medical segmentation.
  • Bridge the semantic gap between generic synthetic shapes and real anatomy by injecting anatomical realism.
  • Propose a structure-aware synthesis pipeline with anatomical anchors and topology constraints.
  • Demonstrate superior downstream segmentation performance on CT and MRI benchmarks compared to FDSL and SSL baselines.

Proposed method

  • Replace primitive shapes with a lightweight Shape Bank derived from 5 real subjects and 32 anatomical classes.
  • Inject anatomical priors via spatial anchors and a topological relation graph to guide sequential placement of organ masks.
  • Formulate synthesis as a constrained spatial point process conditioned on an anatomical graph with unary and binary potentials.
  • Render synthetic images as contour shells to emphasize structural boundaries while providing dense voxel-wise labels.
  • Use a Monte Carlo candidate ranking with an Anatomical Anchor distribution to select plausible organ placements while avoiding biologically infeasible configurations.
Figure 1 : Overall framework. By extracting morphological and spatial priors from minimal real masks, our generator iteratively synthesizes unlimited, biologically plausible data to bridge the semantic gap of FDSL for robust model pre-training and downstream fine-tuning.
Figure 1 : Overall framework. By extracting morphological and spatial priors from minimal real masks, our generator iteratively synthesizes unlimited, biologically plausible data to bridge the semantic gap of FDSL for robust model pre-training and downstream fine-tuning.

Experimental results

Research questions

  • RQ1Can anatomy-informed synthetic supervision close the semantic gap between synthetic data and real anatomy for medical segmentation?
  • RQ2Do structure-aware priors enable pre-training that transfers across modalities (CT to MRI) and backbones (UNETR, SwinUNETR)?
  • RQ3How does the volume of synthetic data affect downstream segmentation performance?
  • RQ4How does the proposed method compare to self-supervised and other synthetic-data baselines in accuracy and data efficiency?

Key findings

  • On BTCV, UNETR: 80.64 average Dice, outperforming scratch by 4.78 and PrimGeoSeg by 1.74.
  • On BTCV, SwinUNETR: 81.53 average Dice, best overall; PrimGeoSeg underperforms scratch in this setting.
  • On MSD Task06 (Lung): UNETR improves by 9.79 over scratch and 1.66 over PrimGeoSeg; SwinUNETR improves by 5.31 and 1.06 respectively.
  • Cross-modality transfer to MRI (MSD Task02 Heart) achieves 96.02 (UNETR) and 95.93 (SwinUNETR), surpassing real-data SSL baselines in some cases.
  • Scaling: 5k synthetic samples offer a practical data-efficiency trade-off with diminishing gains beyond 5k (up to 50k shows smaller marginal gains).
  • Compared to SSL pre-training on real data, synthetic anatomy-informed pre-training can surpass some real-data SSL baselines, highlighting the value of dense anatomical supervision.
Figure 2 : Left: Qualitative comparison results. Red dashes indicate misidentified areas and blue dashes indicate more accurately identified areas. Right: Scaling effect when controlling the generated data number from 500 to 50000.
Figure 2 : Left: Qualitative comparison results. Red dashes indicate misidentified areas and blue dashes indicate more accurately identified areas. Right: Scaling effect when controlling the generated data number from 500 to 50000.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.