TL;DR

This paper proposes a fast, content-adaptive triangular mesh-based medical image registration method that reduces computational cost by operating on a sparse mesh instead of pixel grids. By using mesh-based discretization of the energy functional and solving a sparse linear system, the method achieves faster convergence and higher accuracy than pixel-based curvature registration with DCT solvers, even when implemented in unoptimized MATLAB code.

ABSTRACT

In this paper a fast triangular mesh based registration method is proposed. Having Template and Reference images as inputs, the template image is triangulated using a content adaptive mesh generation algorithm. Considering the pixel values at mesh nodes, interpolated using spline interpolation method for both of the images, the energy functional needed for image registration is minimized. The minimization process was achieved using a mesh based discretization of the distance measure and regularization term which resulted in a sparse system of linear equations, which due to the smaller size in comparison to the pixel-wise registration method, can be solved directly. Mean Squared Difference (MSD) is used as a metric for evaluating the results. Using the mesh based technique, higher speed was achieved compared to pixel-based curvature registration technique with fast DCT solver. The implementation was done in MATLAB without any specific optimization. Higher speeds can be achieved using C/C++ implementations.

Motivation & Objective

  • To address the high computational cost of non-parametric, pixel-wise image registration in medical imaging.
  • To improve registration speed and accuracy by leveraging content-adaptive triangular meshes that conform to curvilinear image features.
  • To develop a mesh-based optimization framework that avoids the need for regular grid re-sampling and reduces degrees of freedom.
  • To demonstrate that mesh-based registration can outperform optimized pixel-based methods in speed and accuracy when implemented efficiently.
  • To enable high-resolution registration without increasing computational complexity by operating on mesh nodes rather than all image pixels.

Proposed method

  • Generates content-adaptive triangular meshes using a diffusion-based method that refines mesh density near image edges and features.
  • Applies spline interpolation to assign pixel intensity values to mesh nodes for both template and reference images.
  • Formulates the image registration energy functional as E[u] = D[Re, Te∘u] + αS[u], with D as Mean Squared Difference (MSD) and S as regularization.
  • Discretizes the distance and regularization terms over the triangular mesh, resulting in a sparse system of linear equations.
  • Solves the sparse linear system directly using standard linear solvers, avoiding iterative methods common in pixel-based approaches.
  • Uses a multi-resolution strategy implicitly through mesh adaptivity, focusing computational effort on feature-rich regions.

Experimental results

Research questions

  • RQ1Can a content-adaptive triangular mesh representation reduce computational complexity in non-rigid medical image registration compared to pixel-based methods?
  • RQ2Does mesh-based registration achieve faster convergence and better accuracy than pixel-based curvature registration with optimized DCT solvers?
  • RQ3Can a mesh-based approach maintain high accuracy while significantly reducing the number of degrees of freedom in the deformation field?
  • RQ4How does the performance of a MATLAB-implented mesh-based method compare to a highly optimized DCT-based pixel method in terms of speed and registration error?
  • RQ5To what extent does mesh adaptivity improve registration accuracy by better capturing curvilinear anatomical boundaries?

Key findings

  • The mesh-based method achieved a mean MSD of 108.91 after 100 iterations, outperforming the pixel-based method’s mean MSD of 116.66.
  • Despite using unoptimized MATLAB code, the mesh-based method completed registration in 1320 seconds, outperforming the pixel-based method’s 1534 seconds.
  • The method reduced computational load by operating on only 3300–5400 mesh nodes instead of 512×512=262,144 pixels, significantly lowering degrees of freedom.
  • The displacement field was accurately recovered, with visual inspection showing improved alignment in the registered image and reduced difference image energy.
  • The mesh-based approach achieved a 14% speedup over the DCT-optimized pixel-based method, indicating potential for even greater gains with C/C++ implementation.
  • Content-adaptive meshing effectively captured curvilinear features such as brain boundaries, enabling more accurate registration than uniform grids.