[Paper Review] First Leptophobic Dark Matter Search from Coherent CAPTAIN-Mills
This paper presents the first search for leptophobic dark matter using coherent elastic scattering in a liquid argon detector, CAPTAIN-Mills (CCM), during an engineering run with 120 photomultiplier tubes and 17.9×10^20 protons-on-target. Despite limited data and contaminated argon, the experiment achieves sensitivity to previously unexplored parameter space, excluding 90% C.L. for dark matter masses between 9 MeV and 50 MeV in a baryonic vector portal model with a mediator-to-DM mass ratio of 2.1.
We report the first results of a search for leptophobic dark matter (DM) from the Coherent CAPTAIN-Mills (CCM) liquid argon (LAr) detector. An engineering run with 120 photomultiplier tubes (PMTs) and $17.9 imes 10^{20}$ protons-on-target (POT) was performed in Fall 2019 to study the characteristics of the CCM detector. The operation of this 10-ton detector was strictly light-based with a threshold of 50 keV and used coherent elastic scattering off argon nuclei to detect DM. Despite only 1.5 months of accumulated luminosity, contaminated LAr, and non-optimized shielding, CCM's first engineering run already achieved sensitivity to previously unexplored parameter space of light dark matter (LDM) models with a baryonic vector portal. With an expected background of 115,005 events, we observe 115,005+16.5 events which is compatible with background expectations. For a benchmark mediator-to-dark matter mass ratio of $m_{_{V_B}}/m_χ=2.1$, DM masses within the range $9\, ext{MeV} \lesssim m_χ\lesssim 50\, ext{MeV}$ have been excluded at 90% C.L. in the leptophobic model after applying the Feldman-Cousins test statistic. CCM's upgraded run with 200 PMTs, filtered LAr, improved shielding, and ten times more POT will be able to exclude the remaining thermal relic density parameter space of this model, as well as probe new parameter space of other leptophobic DM models.
Motivation & Objective
- To search for leptophobic dark matter via coherent elastic scattering in liquid argon using the CCM detector.
- To probe previously unexplored regions of the parameter space for light dark matter models with a baryonic vector portal.
- To demonstrate the sensitivity of a low-cost engineering run with limited data and non-optimized shielding.
- To establish a foundation for future upgrades that will extend sensitivity to thermal relic density targets.
- To validate the use of proton beam-induced rare pion decays as a source of dark matter in fixed-target experiments.
Proposed method
- Utilized coherent elastic scattering of dark matter off ⁴⁰Ar nuclei in a 10-ton liquid argon detector.
- Employed 120 photomultiplier tubes to detect scintillation light from nuclear recoils with a 50 keV energy threshold.
- Performed background estimation using beam-out-of-time windows to model the expected signal from CE$ν$NS.
- Applied the Feldman-Cousins test statistic to compute 90% confidence level exclusion limits.
- Scanned the $m_{V_B}$–$m_\chi$ parameter space over $m_{V_B} = [0.3-134]$ MeV and $m_\chi = [0.1-67]$ MeV to derive limits on the baryonic coupling strength $\alpha_B$.
- Used a frequentist approach consistent with prior MiniBooNE analyses for statistical treatment.
Experimental results
Research questions
- RQ1Can a low-cost engineering run of a liquid argon detector achieve sensitivity to leptophobic dark matter models?
- RQ2What parameter space for light dark matter with a baryonic vector portal can be excluded with only 1.5 months of data and contaminated argon?
- RQ3How does the sensitivity of CCM compare to previous experiments like MiniBooNE and NA62 in the same mass range?
- RQ4To what extent can detector improvements such as filtered argon and better shielding extend the reach of future runs?
- RQ5Can coherent scattering in liquid argon detect dark matter that does not couple to electrons or photons?
Key findings
- CCM120 excluded 90% C.L. for dark matter masses between 9 MeV and 50 MeV in a benchmark leptophobic model with $m_{V_B}/m_\chi = 2.1$.
- The experiment extended the excluded parameter space beyond previous constraints from MiniBooNE and NA62, particularly in the range $2\;\text{MeV} \lesssim m_\chi \lesssim 29\;\text{MeV}$.
- The exclusion limit now covers the thermal relic density target down to $m_\chi \gtrsim 9\;\text{MeV}$, previously unexplored.
- The observed data (115,005 events) was consistent with background expectations (115,005 +16.5 events), showing no significant excess.
- Sensitivity projections for the upgraded CCM200 run with 200 PMTs, filtered argon, and improved shielding indicate potential to exclude the remaining thermal relic density parameter space.
- Even with only 1.5 months of data and an attenuation length of ~50 cm due to contaminated argon, the experiment achieved competitive sensitivity.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.