[Paper Review] First results on low-mass dark matter from the CRESST-III experiment
CRESST-III reports its first low-mass dark matter search results using 2.39 kg·days of data from detector Det-A, achieving a 100 eV energy threshold. Despite background challenges, the experiment improves sensitivity by one order of magnitude at 500 MeV/c² and extends the reach down to 350 MeV/c², reaffirming its leading position in sub-GeV dark matter searches using cryogenic CaWO₄ calorimeters with phonon and light detection via tungsten transition edge sensors.
The CRESST experiment, located at Laboratori Nazionali del Gran Sasso in Italy, searches for dark matter particles via their elastic scattering off nuclei in a target material. The CRESST target consists of scintillating CaWO$_4$ crystals, which are operated as cryogenic calorimeters at millikelvin temperatures. Each interaction in the CaWO$_4$ target crystal produces a phonon signal and a light signal that is measured by a second cryogenic calorimeter. Since the CRESST-II result in 2015, the experiment is leading the field of direct dark matter search for dark matter masses below 1.7\,GeV/$c^2$, extending the reach of direct searches to the sub-GeV/$c^2$ mass region. For CRESST-III, whose Phase 1 started in July 2016, detectors have been optimized to reach the performance required to further probe the low-mass region with unprecedented sensitivity. In this contribution the achievements of the CRESST-III detectors will be discussed together with preliminary results and perspectives of Phase 1.
Motivation & Objective
- To extend direct dark matter searches into the sub-GeV/c² mass regime, where light dark matter particles are predicted.
- To achieve an energy threshold below 100 eV to access coherent elastic scattering signals from low-mass dark matter.
- To optimize cryogenic CaWO₄ detectors with dual phonon and light readout for improved background discrimination.
- To set the first exclusion limits from CRESST-III Phase 1 with a blind analysis and conservative threshold.
- To probe the parameter space favored by previous experiments like CDMS-Si and CoGeNT.
Proposed method
- Cryogenic CaWO₄ crystals are operated at millikelvin temperatures as phonon and scintillation calorimeters.
- Tungsten transition edge sensors (TES) read out phonon and light signals for energy and particle identification.
- A novel instrumented detector holder with TES-equipped support sticks provides a veto against background from support structures.
- A blind analysis is performed using a training set to optimize cuts without bias, followed by application to the final data set.
- Energy-dependent detection efficiencies are measured using artificial nuclear recoil events with known energies.
- The Yellin optimum interval method is used to calculate a 90% confidence level upper limit on the spin-independent dark matter-nucleon cross-section.
Experimental results
Research questions
- RQ1Can CRESST-III achieve a sub-100 eV energy threshold to probe dark matter masses below 1 GeV/c²?
- RQ2What is the sensitivity of CRESST-III Phase 1 to low-mass dark matter, given only 2.39 kg·days of data?
- RQ3How does the observed event rate below 500 eV affect the sensitivity to low-mass dark matter?
- RQ4What is the impact of the 3.7 keV outlier event on the intermediate mass range sensitivity?
- RQ5How does the new CRESST-III result compare to previous CRESST-II limits and other experiments in the low-mass regime?
Key findings
- The CRESST-III experiment achieves a conservative analysis threshold of 100 eV, enabling access to dark matter masses down to 350 MeV/c².
- With only 2.39 kg·days of exposure, the sensitivity at 500 MeV/c² is improved by one order of magnitude compared to CRESST-II Phase 2.
- A total of 33 events are observed in the acceptance region, with a cluster of events from threshold up to 500 eV and one outlier at 3.7 keV.
- The steep rise in event rate below ~500 eV, whose origin remains unknown, limits sensitivity for dark matter masses below ~1 GeV/c².
- The 3.7 keV event is identified as the main contributor to reduced sensitivity in the intermediate mass range (~1–5 GeV/c²).
- The exclusion limit from CRESST-III Phase 1 (solid red in Fig. 6) surpasses the previous CRESST-II limit (dashed red) and is competitive with other leading experiments in the low-mass regime.
Read this paper