[Paper Review] FreMIM: Fourier Transform Meets Masked Image Modeling for Medical Image Segmentation
FreMIM proposes a novel self-supervised pre-training framework for medical image segmentation by leveraging masked image modeling in the Fourier domain, where missing frequency components are reconstructed instead of raw pixels. By exploiting low-frequency semantics and high-frequency details through multi-stage supervision, FreMIM achieves state-of-the-art performance, improving average Dice scores by up to +1.15% over supervised baselines on three benchmark datasets with limited data.
The research community has witnessed the powerful potential of self-supervised Masked Image Modeling (MIM), which enables the models capable of learning visual representation from unlabeled data. In this paper, to incorporate both the crucial global structural information and local details for dense prediction tasks, we alter the perspective to the frequency domain and present a new MIM-based framework named FreMIM for self-supervised pre-training to better accomplish medical image segmentation tasks. Based on the observations that the detailed structural information mainly lies in the high-frequency components and the high-level semantics are abundant in the low-frequency counterparts, we further incorporate multi-stage supervision to guide the representation learning during the pre-training phase. Extensive experiments on three benchmark datasets show the superior advantage of our FreMIM over previous state-of-the-art MIM methods. Compared with various baselines trained from scratch, our FreMIM could consistently bring considerable improvements to model performance. The code will be publicly available at https://github.com/Rubics-Xuan/FreMIM.
Motivation & Objective
- To address the limitation of existing masked image modeling (MIM) methods in capturing both global context and local details in medical images.
- To improve representation learning for medical image segmentation under data-scarce conditions by leveraging frequency-domain priors.
- To develop a multi-stage supervision strategy that guides feature learning across different frequency bands.
- To demonstrate the superiority of frequency-domain reconstruction over pixel-space reconstruction in self-supervised pre-training for medical imaging.
- To validate the effectiveness of foreground-only masking and optimal hyperparameter choices in a data-efficient setting.
Proposed method
- The framework masks random foreground pixels in the spatial domain and reconstructs the corresponding Fourier spectrum instead of raw pixels.
- It applies low-pass and high-pass filters to the Fourier spectrum to extract low-frequency (global) and high-frequency (local detail) components for multi-stage supervision.
- A bilateral aggregation decoder reconstructs the full Fourier spectrum using separate heads for low- and high-frequency components.
- The model is pre-trained using a masked reconstruction loss in the frequency domain, with dynamic loss weighting and frequency band thresholding.
- The pre-trained encoder is fine-tuned on downstream segmentation tasks with standard cross-entropy and Dice loss.
- A static masking ratio of 0.25 is selected as optimal, with ablation studies validating choices of loss weight and frequency passband.
Experimental results
Research questions
- RQ1Can reconstructing the Fourier spectrum instead of raw pixels improve representation learning for medical image segmentation?
- RQ2Does multi-stage supervision on low- and high-frequency components enhance model performance compared to single-stage reconstruction?
- RQ3How does foreground-only masking compare to random patch masking in terms of representation quality and data efficiency?
- RQ4What is the optimal masking ratio and frequency band threshold for pre-training in the frequency domain?
- RQ5Can FreMIM achieve strong performance with minimal labeled data, demonstrating data efficiency in medical imaging?
Key findings
- FreMIM achieves an average Dice score of 84.59% on the BraTS2020 dataset, a +1.15% improvement over the supervised baseline.
- With only one training sample for pre-training, FreMIM boosts performance by +0.61% on average Dice, demonstrating high data efficiency.
- The optimal masking ratio is 0.25, as higher or lower ratios degrade performance due to overly easy or hard reconstruction tasks.
- The loss weight α = 3 and frequency passband threshold PB = 10 yield the best results, with ablation studies confirming their effectiveness.
- The multi-stage supervision strategy significantly improves performance, with the highest gains observed in the ET and TC structures on BraTS.
- FreMIM outperforms previous state-of-the-art MIM methods across all three benchmark datasets, confirming its superiority in representation learning.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.