Skip to main content
QUICK REVIEW

[Paper Review] Frequency Regulation Model of Bulk Power Systems with Energy Storage

Claudio A. Cañizares, Kankar Bhattacharya|arXiv (Cornell University)|Sep 9, 2020
Microgrid Control and OptimizationEngineering10 references6 citations
TL;DR

This paper proposes a detailed dynamic frequency regulation (FR) model for large interconnected power systems integrating Battery and Flywheel Energy Storage Systems (BESS/FESS), accounting for communication delays and State of Charge (SoC) management. Validated on the North American Eastern Interconnection, the model accurately simulates long-term FR dynamics, demonstrating that communication delays and SoC control significantly impact Area Control Error (ACE).

ABSTRACT

This paper presents a dynamic Frequency Regulation (FR) model of a large interconnected power system including Energy Storage Systems (ESSs) such as Battery Energy Storage Systems (BESSs) and Flywheel Energy Storage Systems (FESSs), considering all relevant stages in the frequency control process. Communication delays are considered in the transmission of the signals in the FR control loop and ESSs, and their State of Charge (SoC) management model is considered. The system, ESSs and SoC components are modelled in detail from a FR perspective. The model is validated using real system and ESSs data, based on a practical transient stability model of the North American Eastern Interconnection (NAEI), and the results show that the proposed model accurately represents the FR process of a large interconnected power network including ESS, and can be used for long-term FR studies. The impact of communication delays and SoC management of ESS facilities in the Area Control Error (ACE) is also studied and discussed

Motivation & Objective

  • To develop a comprehensive dynamic frequency regulation model for large interconnected power systems incorporating Energy Storage Systems (ESS).
  • To integrate realistic communication delays in the FR control loop and model their impact on system stability.
  • To include a detailed State of Charge (SoC) management strategy for ESS within the FR framework.
  • To validate the model using real system and ESS data from the North American Eastern Interconnection (NAEI).
  • To analyze the influence of communication delays and SoC management on Area Control Error (ACE) in bulk power systems.

Proposed method

  • Develops a dynamic model of the entire frequency control process, including primary, secondary, and tertiary control stages.
  • Incorporates communication delays in the transmission of control signals within the FR control loop using time-delayed transfer functions.
  • Models ESS components (BESS and FESS) with detailed electrical and control dynamics relevant to frequency support.
  • Integrates a State of Charge (SoC) management model that regulates ESS operation to prevent overcharging or deep discharge.
  • Uses a practical transient stability model of the North American Eastern Interconnection (NAEI) as the test system for validation.
  • Validates the model by comparing simulated FR responses with real-world system and ESS data under various disturbance scenarios.

Experimental results

Research questions

  • RQ1How do communication delays in the FR control loop affect the dynamic response and stability of a bulk power system with ESS?
  • RQ2To what extent does ESS SoC management influence the performance of frequency regulation in large interconnected systems?
  • RQ3Can the proposed FR model accurately represent the transient and long-term behavior of a real large-scale power system with ESS?
  • RQ4How do the combined effects of communication delays and SoC constraints impact the Area Control Error (ACE) in the control area?
  • RQ5What is the validity of the model when tested against real system and ESS operational data?

Key findings

  • The proposed FR model accurately replicates the dynamic behavior of the North American Eastern Interconnection (NAEI) under various disturbance conditions.
  • Communication delays in the FR control loop significantly degrade system damping and increase ACE oscillations, especially under high ESS penetration.
  • SoC management of ESS facilities introduces additional constraints that affect the duration and magnitude of frequency support, particularly during prolonged disturbances.
  • The model effectively captures the interaction between ESS control dynamics and system-wide frequency response, enabling reliable long-term FR studies.
  • The inclusion of both communication delays and SoC management improves the model's realism and alignment with actual system performance.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.