[Paper Review] From Cold Start to Active Learning: Embedding-Based Scan Selection for Medical Image Segmentation
The paper introduces a two-stage framework that first uses foundation-model embeddings and clustering to seed a diverse cold-start training set, then applies an uncertainty–diversity active-learning strategy to acquire additional labels for medical image segmentation. It reports consistent gains in Dice and Hausdorff distance across X-ray and MRI datasets in low-data regimes.
Accurate segmentation annotations are critical for disease monitoring, yet manual labeling remains a major bottleneck due to the time and expertise required. Active learning (AL) alleviates this burden by prioritizing informative samples for annotation, typically through a diversity-based cold-start phase followed by uncertainty-driven selection. We propose a novel cold-start sampling strategy that combines foundation-model embeddings with clustering, including automatic selection of the number of clusters and proportional sampling across clusters, to construct a diverse and representative initial training. This is followed by an uncertainty-based AL framework that integrates spatial diversity to guide sample selection. The proposed method is intuitive and interpretable, enabling visualization of the feature-space distribution of candidate samples. We evaluate our approach on three datasets spanning X-ray and MRI modalities. On the CheXmask dataset, the cold-start strategy outperforms random selection, improving Dice from 0.918 to 0.929 and reducing the Hausdorff distance from 32.41 to 27.66 mm. In the AL setting, combined entropy and diversity selection improves Dice from 0.919 to 0.939 and reduces the Hausdorff distance from 30.10 to 19.16 mm. On the Montgomery dataset, cold-start gains are substantial, with Dice improving from 0.928 to 0.950 and Hausdorff distance decreasing from 14.22 to 9.38 mm. On the SynthStrip dataset, cold-start selection slightly affects Dice but reduces the Hausdorff distance from 9.43 to 8.69 mm, while active learning improves Dice from 0.816 to 0.826 and reduces the Hausdorff distance from 7.76 to 6.38 mm. Overall, the proposed framework consistently outperforms baseline methods in low-data regimes, improving segmentation accuracy.
Motivation & Objective
- Motivate label-efficient medical image segmentation due to labeling cost and expertise constraints.
- Propose a two-stage framework combining diverse cold-start initialization with uncertainty-aware active learning.
- Enable interpretable visualization of the sampling process by operating in a low-dimensional feature space.
- Demonstrate improved segmentation performance on multiple datasets under low labeling budgets.
Proposed method
- Extract foundation-model embeddings from medical images and project to 2D with t-SNE for visualization and distance computations.
- Perform k-means clustering over 2D embeddings with multiple candidate k values and select the configuration that maximizes the mean silhouette score.
- Choose cluster medoids as initial seeds and allocate the remaining budget proportionally to cluster sizes, with farthest-point sampling within clusters for diversity.
- Train an initial segmentation model on the cold-start seeds and iteratively acquire more samples using a combined image-level entropy and spatial-diversity score.
- Compute image-level entropy from pixel-wise class probabilities and normalize; measure spatial diversity as distance to nearest already-selected sample in 2D embedding; combine with a trade-off parameter alpha to obtain acquisition score S(i).
- Iteratively select samples with the highest S(i) until the labeling budget is exhausted.

Experimental results
Research questions
- RQ1Does embedding-based clustering provide a better diverse and representative cold-start than random sampling or naive clustering in medical image segmentation?
- RQ2Can an entropy-based uncertainty signal combined with spatial diversity improve sample efficiency during active learning for segmentation?
- RQ3How does the proposed method perform across multiple modalities and organs with varying data regimes (SynthStrip, Montgomery, CheXmask-300)?
Key findings
- Cold-start with foundation-model embeddings and silhouette-optimized clustering improves Dice and reduces Hausdorff distance over random selection on all datasets (e.g., CheXmask: Dice 0.929 vs 0.918; HD 27.66 mm vs 32.41 mm).
- In the active-learning stage, combining entropy and diversity yields further gains (e.g., CheXmask-300: Dice 0.936–0.939 and HD 19.16–20.0 mm depending on setup).
- On Montgomery, cold-start gains are substantial (Dice up to 0.950; HD down to 9.38–20.44 mm range across budgets).
- On SynthStrip, cold-start raises Dice modestly while reducing HD (HD from 9.43 to 8.69 mm); active learning improves Dice from 0.816 to 0.826 and HD from 7.76 to 6.38 mm.
- Across datasets, the proposed method consistently matches or outperforms baselines in low-data regimes and reduces result variability compared to random sampling.

Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.