[Paper Review] From Scanning Guidelines to Action: A Robotic Ultrasound Agent with LLM-Based Reasoning
An RL-finetuned LLM acts as a guideline-driven high-level planner to autonomously control robotic ultrasound scanning using a set of tools, demonstrated in verbal guideline tests and real-world scans of gallbladder, spine, and kidney.
Robotic ultrasound offers advantages over free-hand scanning, including improved reproducibility and reduced operator dependency. In clinical practice, US acquisition relies heavily on the sonographer's experience and situational judgment. When transferring this process to robotic systems, such expertise is often encoded explicitly through fixed procedures and task-specific models, yielding pipelines that can be difficult to adapt to new scanning tasks. In this work, we propose a unified framework for autonomous robotic US scanning that leverages a LLM-based agent to interpret US scanning guidelines and execute scans by dynamically invoking a set of provided software tools. Instead of encoding fixed scanning procedures, the LLM agent retrieves and reasons over guideline steps from scanning handbooks and adapts its planning decisions based on observations and the current scanning state. This enables the system to handle variable and decision-dependent workflows, such as adjusting scanning strategies, repeating steps, or selecting the appropriate next tool call in response to image quality or anatomical findings. Because the reasoning underlying tool selection is also critical for transparent and trustworthy planning, we further fine tune the LLM agent using a RL based strategy to improve both its reasoning quality and the correctness of tool selection and parameterization, while maintaining robust generalization to unseen guidelines and related tasks. We first validate the approach via verbal execution on 10 US scanning guidelines, assessing reasoning as well as tool selection and parameterization, and showing the benefit of RL fine tuning. We then demonstrate real world feasibility on robotic scanning of the gallbladder, spine, and kidney. Overall, the framework follows diverse guidelines and enables reliable autonomous scanning across multiple anatomical targets within a unified system.
Motivation & Objective
- Motivate autonomous robotic ultrasound to reduce operator dependency and improve reproducibility by using guideline-driven planning.
- Create an agent that retrieves scanning steps from handbooks and reason over current observations to decide tool use.
- Enable flexible, non-fixed workflows including repeating steps, adapting strategies, and adjusting probe actions.
- Enhance reliability and generalization by fine-tuning a smaller LLM with RL for better reasoning and tool selection.
Proposed method
- Use an LLM as a high-level planner that retrieves guideline steps via retrieval-augmented generation.
- Represent decisions as <think> reasoning traces followed by <tool> JSON calls to a toolkit of perception and robot-control utilities.
- Implement three categories of tools: Trajectory Planning, Robot Execution, and Quality/Patient Interaction (contact adjustment and voice guidance).
- Fine-tune a smaller model with supervised learning on reference traces and then apply Proximal Policy Optimization (PPO) with a custom reward to improve tool-calling accuracy and reasoning.
- Evaluate on held-out guidelines for tool-use accuracy and task success, then validate end-to-end on real robotic scans of gallbladder, spine, and kidney.
- Incorporate a reward structure that penalizes incorrect tool names and rewards correct tool and parameterization, enabling robust generalization to unseen guidelines.
Experimental results
Research questions
- RQ1Can an LLM-driven agent interpret diverse ultrasound scanning guidelines to generate executable tool calls for autonomous robotic US?
- RQ2Does RL fine-tuning improve the consistency and correctness of tool selection and parameterization compared to a base model?
- RQ3Is the system capable of robust end-to-end autonomous scanning across multiple anatomical targets (gallbladder, spine, kidney)?
- RQ4How well does guideline-driven planning transfer to real-world robotic ultrasound with acceptable success rates and safety?
Key findings
- RL fine-tuning improves step-wise tool-use accuracy from 0.6512 to 0.8973.
- RL fine-tuning improves overall scanning task success rate from 0.5384 to 0.9230.
- Verbal experiments show more coherent and task-relevant reasoning traces with RL fine-tuning.
- Real-world robotic experiments achieved successful spine and kidney scans across volunteers; gallbladder scans had one failure due to procedure complexity.
- The system demonstrates reliable autonomous scanning across gallbladder, spine, and kidney within a unified pipeline.