Skip to main content
QUICK REVIEW

[Paper Review] Full-field Brillouin microscopy based on an imaging Fourier transform spectrometer

Carlo Bevilacqua, Robert Prevedel|arXiv (Cornell University)|Sep 3, 2024
Photoacoustic and Ultrasonic ImagingEngineering3 citations
TL;DR

This paper presents a full-field Brillouin microscopy technique using a custom imaging Fourier transform spectrometer to achieve rapid, high-throughput spectral acquisition of Brillouin scattering. By leveraging the symmetric properties of the Brillouin spectrum, the method attains a throughput of up to 40,000 spectra per second over a 300 µm field of view, representing a ~1,000-fold speed improvement over conventional confocal methods while preserving high spatial resolution and enabling non-invasive 3D imaging of biological samples.

ABSTRACT

Brillouin microscopy is an emerging optical elastography technique that can be used to assess mechanical properties of biological samples in a 3D, all-optical and hence non-contact fashion. However, the low cross-section of spontaneous Brillouin scattering results in weak signals typically requiring prolonged exposure times or illumination dosages potentially harmful for biological samples. Here, we present a new approach for highly-multiplexed, and therefore rapid, spectral acquisition of the Brillouin scattered light. Specifically, by exploiting a custom-built Fourier-transform imaging spectrometer and the symmetric properties of the Brillouin spectrum, we experimentally demonstrate full-field 2D spectral Brillouin imaging of phantoms as well as biological samples, at a throughput of up to 40,000 spectra per second over a ~300um field-of-view. This represents an approximately three orders of magnitude improvement in speed and throughput compared to standard confocal methods while retaining high spatial resolution and the capability to acquire three-dimensional images of photosensitive samples in biology and medicine.

Motivation & Objective

  • To overcome the low signal strength and slow acquisition speeds of conventional Brillouin microscopy in biological applications.
  • To enable rapid, full-field 2D spectral imaging of Brillouin scattering with high throughput and spatial resolution.
  • To reduce exposure time and illumination dosage to minimize photodamage in photosensitive biological samples.
  • To develop a method compatible with 3D imaging of soft biological tissues using all-optical, non-contact measurement.
  • To demonstrate the feasibility of high-speed, multiplexed spectral acquisition using symmetric spectral properties of Brillouin scattering.

Proposed method

  • The method employs a custom-built imaging Fourier transform spectrometer (IFTS) to capture interferograms across the entire field of view simultaneously.
  • The IFTS enables full-field spectral acquisition by measuring the interference pattern of broadband light across a 2D spatial array.
  • The symmetric nature of the Brillouin spectrum is exploited to reconstruct the full spectrum from a single interferogram, enhancing signal-to-noise and throughput.
  • Spatial and spectral multiplexing are achieved through a Michelson interferometer configuration with a 2D detector, allowing simultaneous acquisition of spectra from all spatial points.
  • The system uses a 2D camera to record interferograms, which are then Fourier-transformed to retrieve the spectral information across the field of view.
  • The approach enables real-time, non-scanning, full-field spectral imaging at a rate of up to 40,000 spectra per second over a ~300 µm field of view.

Experimental results

Research questions

  • RQ1Can a full-field Brillouin microscopy system achieve significantly higher throughput than conventional confocal methods?
  • RQ2Can the symmetric properties of the Brillouin spectrum be leveraged to improve spectral reconstruction efficiency and signal-to-noise ratio?
  • RQ3Can high-speed, full-field 2D spectral imaging be achieved without compromising spatial resolution or introducing photodamage to biological samples?
  • RQ4Is it feasible to perform 3D mechanical imaging of soft biological tissues using this high-throughput, all-optical method?
  • RQ5Can the imaging Fourier transform spectrometer enable real-time, non-scanning spectral acquisition across a wide field of view?

Key findings

  • The system achieves a spectral acquisition throughput of up to 40,000 spectra per second over a ~300 µm field of view, representing a ~1,000-fold improvement over standard confocal Brillouin microscopy.
  • The method enables full-field 2D spectral imaging with high spatial resolution, preserving the ability to perform 3D mechanical imaging of biological samples.
  • The symmetric nature of the Brillouin spectrum allows for efficient spectral reconstruction, enhancing signal-to-noise and throughput without additional scanning.
  • The technique enables non-invasive, all-optical, and non-contact 3D imaging of phantoms and biological samples with reduced exposure times and lower illumination dosage.
  • The system was experimentally validated on both phantoms and biological samples, demonstrating robust spectral acquisition and imaging fidelity.
  • The approach maintains high spectral and spatial resolution while drastically reducing acquisition time, making it suitable for live-cell and dynamic biological imaging.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.