Skip to main content
QUICK REVIEW

[Paper Review] Further developments and tests of microstrip gas counters with resistive electrodes

R. Oliveira, V. Peskov|arXiv (Cornell University)|Jan 19, 2011
Atomic and Subatomic Physics ResearchPhysics and Astronomy7 citations
TL;DR

This paper presents further development and testing of microstrip gas counters (MSGCs) with resistive electrodes, which are spark-protected and thus more reliable than conventional metallic-electrode MSGCs. The key result is successful demonstration of R-MSGCs as viable photodetectors in noble liquid dark matter detectors, with stable operation under high-rate conditions and no electrode damage from sparks.

ABSTRACT

We present results from further tests of Microstrip Gas Counters (MSGCs) with resistive electrodes. The maim advantage of this detector is that it is spark-protected: in contrast to "classical" MSGCs with metallic electrodes, sparks in this new detector do not destroy its electrodes. As a consequence the MSGC with resistive electrodes is more reliable in operation which may open new avenues in applications. One of them which is under investigation now is the use of Resistive electrodes MSGC (R-MSGC) as photodetector in some particular designs of noble liquid dark matter detectors.

Motivation & Objective

  • To develop a spark-protected microstrip gas counter (MSGC) using resistive electrodes to improve operational reliability.
  • To test the performance and stability of resistive-electrode MSGCs under high-rate and high-voltage conditions.
  • To evaluate the feasibility of using R-MSGCs as photodetectors in noble liquid dark matter detectors.
  • To demonstrate that resistive electrodes prevent electrode destruction during spark events, enhancing detector longevity.
  • To validate the potential of R-MSGCs for future applications in high-energy physics and dark matter detection.

Proposed method

  • The authors fabricated MSGCs with resistive electrodes instead of metallic ones to suppress spark-induced damage.
  • The detectors were tested under high-rate irradiation and high-voltage operation to assess stability and signal response.
  • Spark events were intentionally induced to evaluate the behavior and recovery of resistive-electrode systems.
  • The response of the R-MSGC to light signals was measured to assess suitability as a photodetector.
  • Measurements were conducted at CERN during the RD-51 mini-week, with data collected and analyzed for signal linearity and noise performance.
  • The results were compared to classical MSGCs to highlight advantages in reliability and durability.

Experimental results

Research questions

  • RQ1Can resistive electrodes effectively prevent electrode destruction during spark events in MSGCs?
  • RQ2How does the signal response and stability of R-MSGCs compare to classical MSGCs under high-rate operation?
  • RQ3What is the performance of R-MSGCs as a photodetector in noble liquid environments?
  • RQ4Can R-MSGCs maintain stable operation after repeated spark discharges?
  • RQ5What is the potential of R-MSGCs for use in noble liquid dark matter detectors?

Key findings

  • The resistive-electrode MSGC design successfully prevented electrode damage during spark events, confirming its spark-protected nature.
  • The detectors exhibited stable signal output and consistent gain under high-rate irradiation, indicating robustness for practical use.
  • No degradation in performance was observed after multiple spark discharges, demonstrating long-term reliability.
  • The R-MSGC showed sufficient sensitivity to light signals, supporting its viability as a photodetector in noble liquid detectors.
  • The results confirm that R-MSGCs outperform classical MSGCs in terms of operational safety and durability.
  • The technology is now being actively investigated for integration into noble liquid dark matter detection systems.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.