Md Mostafijur Rahman, Radu Mărculescu|arXiv (Cornell University)|Oct 24, 2023
Radiomics and Machine Learning in Medical ImagingMedicine6 citations
TL;DR

G-CASCADE proposes a novel graph convolutional decoder for 2D medical image segmentation that enhances feature refinement through cascaded graph convolutional attention modules, preserving long-range dependencies from vision transformer encoders. It achieves state-of-the-art performance with 80.8% fewer parameters and 82.3% fewer FLOPs than the SOTA CASCADE decoder across five medical segmentation benchmarks.

ABSTRACT

In recent years, medical image segmentation has become an important application in the field of computer-aided diagnosis. In this paper, we are the first to propose a new graph convolution-based decoder namely, Cascaded Graph Convolutional Attention Decoder (G-CASCADE), for 2D medical image segmentation. G-CASCADE progressively refines multi-stage feature maps generated by hierarchical transformer encoders with an efficient graph convolution block. The encoder utilizes the self-attention mechanism to capture long-range dependencies, while the decoder refines the feature maps preserving long-range information due to the global receptive fields of the graph convolution block. Rigorous evaluations of our decoder with multiple transformer encoders on five medical image segmentation tasks (i.e., Abdomen organs, Cardiac organs, Polyp lesions, Skin lesions, and Retinal vessels) show that our model outperforms other state-of-the-art (SOTA) methods. We also demonstrate that our decoder achieves better DICE scores than the SOTA CASCADE decoder with 80.8% fewer parameters and 82.3% fewer FLOPs. Our decoder can easily be used with other hierarchical encoders for general-purpose semantic and medical image segmentation tasks.

Motivation & Objective

  • To address the limitation of existing decoders in preserving long-range spatial dependencies in medical image segmentation.
  • To improve computational efficiency without sacrificing segmentation accuracy in transformer-based architectures.
  • To introduce a novel graph convolution-based decoder that enhances multi-scale feature refinement in hierarchical vision transformers.
  • To demonstrate the generalizability of the G-CASCADE decoder across diverse medical image segmentation tasks.

Proposed method

  • G-CASCADE employs a cascaded decoder architecture that progressively refines multi-stage features from hierarchical vision transformer encoders.
  • It introduces a Graph Convolutional Attention Module (GCAM) that combines spatial attention with global receptive fields via graph convolution to preserve long-range context.
  • The decoder uses an efficient up-convolution block (UCB) that reduces computational cost while maintaining performance.
  • Graph convolution blocks (GCB) are used in place of standard 3×3 convolutions to enable global feature aggregation and reduce parameter count.
  • Skip-connections are aggregated using additive concatenation, which balances performance and computational efficiency.
  • The model is trained end-to-end with cross-entropy and Dice loss on multiple public medical image segmentation datasets.

Experimental results

Research questions

  • RQ1Can a graph convolution-based decoder outperform convolution-based decoders in preserving long-range dependencies for 2D medical image segmentation?
  • RQ2How does the proposed G-CASCADE decoder compare in accuracy and efficiency to the SOTA CASCADE decoder?
  • RQ3What is the optimal architectural configuration of graph convolution and spatial attention modules in the GCAM block?
  • RQ4Does the G-CASCADE decoder generalize across diverse medical image segmentation tasks with varying anatomical structures and lesion types?
  • RQ5How does the choice of skip-connection aggregation (addition vs. concatenation) affect performance and computational cost?

Key findings

  • G-CASCADE achieves a DICE score of 83.28% on the Synapse Multi-organ dataset using PVTv2-b2, outperforming the baseline CASCADE decoder by 0.5% with 80.8% fewer parameters and 82.3% fewer FLOPs.
  • The G-CASCADE decoder achieves a 3.2% improvement in DICE score over a non-cascaded baseline when using both GCB and SPA modules.
  • The GCB followed by SPA configuration in GCAM yields better performance than the reverse order, with a 0.4% higher DICE score.
  • Additive aggregation of skip-connections reduces computational cost by 60% compared to concatenation while maintaining comparable performance.
  • On the MERIT backbone, G-CASCADE achieves 84.63% DICE with 4.27G FLOPs and 5.99M parameters, outperforming SOTA methods on five benchmarks.
  • Ablation studies confirm that the cascaded structure, GCB, and SPA modules each contribute significantly to performance, with the full configuration achieving the highest DICE score.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.