K. Hagiwara, T. Yano|arXiv (Cornell University)|Sep 10, 2018
Nuclear Physics and ApplicationsPhysics and Astronomy36 references8 citations
TL;DR

This study presents a precise model for the gamma-ray spectrum from thermal neutron capture on enriched 157Gd, combining measured high-energy peaks (up to 8 MeV) with theoretical nuclear level density and photon strength function inputs for the continuum. The model, validated via Geant4 Monte Carlo simulation and calibrated with 60Co, 137Cs, 152Eu, and 35Cl(n,γ) sources, achieves sub-10% agreement across 14 HPGe detectors, enabling accurate neutron tagging in neutrino detectors like Super-Kamiokande.

ABSTRACT

We have measured the $γ$-ray energy spectrum from the thermal neutron capture, ${}^{157}$Gd$(n,γ){}^{158}$Gd, on an enriched $^{157}$Gd target (Gd$_{2}$O$_{3}$) in the energy range from 0.11 MeV up to about 8 MeV. The target was placed inside the germanium spectrometer of the ANNRI detector at J-PARC and exposed to a neutron beam from the Japan Spallation Neutron Source (JSNS). Radioactive sources ($^{60}$Co, $^{137}$Cs, and $^{152}$Eu) and the reaction $^{35}$Cl($n$,$γ$) were used to determine the spectrometer's detection efficiency for $γ$ rays at energies from 0.3 to 8.5 MeV. Using a Geant4-based Monte Carlo simulation of the detector and based on our data, we have developed a model to describe the $γ$-ray spectrum from the thermal ${}^{157}$Gd($n$,$γ$) reaction. While we include the strength information of 15 prominent peaks above 5 MeV and associated peaks below 1.6 MeV from our data directly into the model, we rely on the theoretical inputs of nuclear level density and the photon strength function of ${}^{158}$Gd to describe the continuum $γ$-ray spectrum from the ${}^{157}$Gd($n$,$γ$) reaction. Our model combines these two components. The results of the comparison between the observed $γ$-ray spectra from the reaction and the model are reported in detail.

Motivation & Objective

  • To measure the full gamma-ray energy spectrum from thermal neutron capture on 157Gd, covering 0.11–8 MeV.
  • To develop a precise model for the gamma-ray spectrum that combines experimental data and theoretical nuclear structure inputs.
  • To calibrate and validate the detection efficiency of a high-purity germanium spectrometer (ANNRI) across a wide energy range and solid angle.
  • To enable accurate Monte Carlo simulations for neutron tagging in large-scale neutrino detectors such as Super-Kamiokande.
  • To support non-hermetic anti-neutrino monitors by improving the modeling of gamma-ray cascade energy deposition.

Proposed method

  • Measured the 157Gd(n,γ) gamma-ray spectrum using an enriched 157Gd2O3 target in the ANNRI detector at J-PARC.
  • Used radioactive sources (60Co, 137Cs, 152Eu) and the 35Cl(n,γ) reaction to calibrate the HPGe detector's efficiency from 0.3 to 8.5 MeV.
  • Applied a Geant4-based Monte Carlo simulation to model the detector response and optimize efficiency corrections.
  • Fitted single and coincidence detection efficiencies using a χ² minimization approach with dead time and angular correlation corrections.
  • Incorporated 15 prominent gamma-ray peaks above 5 MeV and associated lower-energy peaks directly from data, while modeling the continuum using theoretical photon strength function and level density of 158Gd.
  • Validated the model by comparing simulated spectra (M2H2, M3H3) with measured data, achieving <10% deviation across all crystal pairs.

Experimental results

Research questions

  • RQ1What is the complete gamma-ray energy spectrum from thermal neutron capture on 157Gd from 0.11 MeV to 8 MeV?
  • RQ2How accurately can the detector's photopeak efficiency be modeled across a wide energy range and solid angle using Geant4 simulation?
  • RQ3To what extent does the measured spectrum of 157Gd(n,γ) agree with a hybrid model combining experimental peaks and theoretical continuum?
  • RQ4How well does the model reproduce multiplicity-dependent spectra (e.g., M2H2, M3H3) observed in the data?
  • RQ5Can the model support reliable neutron tagging in Cherenkov neutrino detectors like Super-Kamiokande?

Key findings

  • The model achieves a weighted mean ratio of data-to-simulation efficiency within 10% of unity across all 14 HPGe crystals and 11 energy points.
  • The maximum deviation between measured and simulated single photopeak efficiencies is approximately 20%, with a weighted sample standard deviation of 6%.
  • The 35Cl(n,γ) reaction at 7414 keV served as a normalization reference, showing perfect agreement (ratio = 1) with simulation.
  • The model successfully reproduces the M2H2 and M3H3 gamma-ray spectra, with softening trends consistent with cascade emission physics.
  • The optimal dead time correction factor was determined to be C = 0.225, ensuring consistency between fitted and nominal live-time values.
  • The final single photopeak efficiency for all 14 crystals combined is (1.3 ± 0.1)% at 1.3 MeV, with high uniformity across the detector solid angle.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.