TL;DR

This paper presents gate-tunable graphene Hall sensors with hBN encapsulation and graphite back-gating, achieving ultrahigh magnetic field sensitivity of 80 nT/Hz¹/² at liquid helium temperatures. The devices exhibit minimal charge inhomogeneity and tunable carrier density, enabling precise Hall measurements with suppressed noise and robust quantum Hall plateaus at low magnetic fields (as low as 40 mT).

ABSTRACT

Solid-state magnetic field sensors are important to both modern electronics and fundamental materials science. Many types of these sensors maintain high sensitivity only in a limited range of temperature and background magnetic field, but Hall-effect sensors are in principle able to operate over a broad range of these conditions. Here, we fabricate and characterize micrometer-scale graphene Hall sensors demonstrating high magnetic field sensitivity from liquid-helium to room temperature and in background magnetic field up to several Tesla. By tuning the charge carrier density with an electrostatic gate, we optimize the magnetic field sensitivity for different working conditions. From measurements of the Hall coefficient and the Hall voltage noise at 1 kHz, we estimate an optimum magnetic field sensitivity of 80 nT Hz$^{-1/2}$ at 4.2 K, 700 nT Hz$^{-1/2}$ at room temperature, and 3 $μ$T Hz$^{-1/2}$ in 3 T background magnetic field at 4.2 K. Our devices perform competitively with the best existing Hall sensor technologies at room temperature, outperform any Hall sensors reported in the literature at 4.2 K, and demonstrate high sensitivity for the first time in a few Tesla applied magnetic field.

Motivation & Objective

  • To develop graphene Hall sensors with enhanced magnetic field sensitivity by minimizing charge inhomogeneity and noise.
  • To achieve high-sensitivity Hall measurements at low magnetic fields (down to 40 mT) using gate-tunable graphene devices.
  • To reduce contact resistance and improve device stability through optimized fabrication, including selective etching and low-pressure electron-beam evaporation.
  • To investigate the role of gate electrodes (graphite vs. Si/SiO₂) in controlling carrier density and minimizing disorder.
  • To characterize the temperature dependence of Hall response and noise, including room-temperature operation.

Proposed method

  • Fabricated monolayer graphene/hBN heterostructures using dry transfer of exfoliated flakes with intentional misalignment to avoid Moiré patterns.
  • Employed a poly(carbonate)/PDMS stamp for precise dry transfer, followed by high-temperature annealing (300 °C, <10⁻⁶ Torr) to remove polymer residues.
  • Used CHF₃/O₂/Ar inductively coupled plasma etching to selectively etch hBN, increasing metal-graphene contact area and reducing contact resistance.
  • Applied graphite back-gates and top gates to independently tune the Hall cross and contacts, minimizing charge inhomogeneity (δn ~ 4×10⁹ cm⁻² in best device).
  • Measured Hall resistance (R_H) and noise spectral density (S_V, S_B) at 1 kHz, with noise modeled using a Lorentzian + 1/f noise function: S_V = [4δV²/(τ₁+τ₂)]·[τ²/(1+(2πfτ)²)] + A/f.
  • Conducted low-temperature (4.2 K) and room-temperature measurements using a cryostat insert in a C-frame electromagnet, with bias current varied to probe carrier density gradients.

Experimental results

Research questions

  • RQ1Can graphite-gated, hBN-encapsulated graphene Hall sensors achieve sub-100 nT/Hz¹/² magnetic field sensitivity at low temperatures?
  • RQ2How does charge inhomogeneity (δn) affect the visibility and stability of quantum Hall plateaus in graphene Hall sensors?
  • RQ3What is the impact of gate electrode type (graphite vs. Si/SiO₂) on contact resistance, Hall coefficient, and noise performance?
  • RQ4How does bias current influence carrier density gradients and Hall response in graphene Hall devices?
  • RQ5To what extent does room-temperature operation preserve high magnetic field sensitivity and low noise in these devices?

Key findings

  • The best device (D1) achieved a minimum magnetic field sensitivity of 80 nT/Hz¹/² at 1 kHz, with a peak Hall coefficient of ~1.5×10⁴ V·s/T·C.
  • Quantum Hall plateaus emerged at magnetic fields as low as 40 mT in D1, indicating high mobility and low disorder.
  • Charge inhomogeneity δn was measured at ~4×10⁹ cm⁻² in D1, significantly lower than in comparable Si-gated devices (δn ~10¹⁰ cm⁻²), due to effective screening by graphite gates.
  • Applying a gate voltage to the contacts in D1 reduced both two-point resistance and voltage noise without degrading the peak Hall coefficient.
  • At room temperature, the device maintained a minimum S_B¹/² of ~700 nT/Hz¹/² under small hole doping, demonstrating robust performance at elevated temperatures.
  • Noise analysis revealed two-state voltage fluctuations with lifetimes τ₁ = 3.9 ms and τ₂ = 49 ms, well-modeled by a Lorentzian + 1/f noise spectrum with A ≈ 3.1×10⁻¹² V and δV ≈ 52.5 µV.