Skip to main content
QUICK REVIEW

[Paper Review] Gaussian process emulation for discontinuous response surfaces with applications for cardiac electrophysiology models

Sanmitra Ghosh, David J. Gavaghan|arXiv (Cornell University)|May 25, 2018
Fault Detection and Control SystemsEngineering35 references8 citations
TL;DR

This paper proposes a two-step Gaussian process (GP) emulator for discontinuous response surfaces in cardiac electrophysiology models, where bifurcations cause abrupt changes in action potential duration (APD). It uses a GP classifier to detect discontinuity boundaries and constrains GP regression within these regions, enabling accurate uncertainty quantification with 10% of the computational cost of full simulations and under one minute inference time on 100,000 test points.

ABSTRACT

Mathematical models of biological systems are beginning to be used for safety-critical applications, where large numbers of repeated model evaluations are required to perform uncertainty quantification and sensitivity analysis. Most of these models are nonlinear both in variables and parameters/inputs which has two consequences. First, analytic solutions are rarely available so repeated evaluation of these models by numerically solving differential equations incurs a significant computational burden. Second, many models undergo bifurcations in behaviour as parameters are varied. As a result, simulation outputs often contain discontinuities as we change parameter values and move through parameter/input space. Statistical emulators such as Gaussian processes are frequently used to reduce the computational cost of uncertainty quantification, but discontinuities render a standard Gaussian process emulation approach unsuitable as these emulators assume a smooth and continuous response to changes in parameter values. In this article, we propose a novel two-step method for building a Gaussian Process emulator for models with discontinuous response surfaces. We first use a Gaussian Process classifier to detect boundaries of discontinuities and then constrain the Gaussian Process emulation of the response surface within these boundaries. We introduce a novel `certainty metric' to guide active learning for a multi-class probabilistic classifier. We apply the new classifier to simulations of drug action on a cardiac electrophysiology model, to propagate our uncertainty in a drug's action through to predictions of changes to the cardiac action potential. The proposed two-step active learning method significantly reduces the computational cost of emulating models that undergo multiple bifurcations.

Motivation & Objective

  • To address the challenge of emulating cardiac electrophysiology models with discontinuous response surfaces due to bifurcations in dynamics.
  • To reduce the computational burden of uncertainty quantification and sensitivity analysis in safety-critical biological models.
  • To develop a statistical emulator that remains accurate despite abrupt changes in output (e.g., APD) across parameter space.
  • To introduce a novel active learning scheme guided by a certainty metric for efficient boundary detection.
  • To enable scalable uncertainty propagation from experimental drug screening data to whole-cell electrophysiological predictions.

Proposed method

  • A two-step framework: first, a multi-class GP classifier detects discontinuity boundaries in parameter space using a novel certainty metric for active learning.
  • The certainty metric quantifies classifier confidence, guiding where to sample next to improve boundary detection with minimal simulations.
  • Within each identified region, a sparse GP regression model (using FITC approximation) emulates the APD response surface.
  • Active learning prioritizes sampling near uncertain boundaries, reducing the number of required simulator evaluations.
  • The method combines probabilistic classification with GP regression, leveraging uncertainty quantification in both stages.
  • The emulator is trained on a small number of simulator runs and used to predict APD across large parameter spaces efficiently.

Experimental results

Research questions

  • RQ1Can a statistical emulator accurately model discontinuous response surfaces in cardiac electrophysiology models where bifurcations cause abrupt changes in action potential duration?
  • RQ2How can active learning guided by a certainty metric improve the efficiency of boundary detection in high-dimensional parameter space?
  • RQ3What is the computational cost and prediction accuracy of a two-step GP emulator compared to full simulation for uncertainty quantification?
  • RQ4Can the proposed method be extended to other biomarkers or biophysical models with similar bifurcation behavior?
  • RQ5How does the use of a probabilistic GP classifier improve robustness to numerical errors near bifurcation points?

Key findings

  • The two-step GP emulator achieved high prediction accuracy on a test set of 100,000 points, with a computational cost of only about 10% of full simulation.
  • Prediction inference on the entire test set took less than one minute using sparse GP approximation (FITC).
  • The active learning scheme guided by the certainty metric significantly reduced the number of required simulator evaluations.
  • The GP classifier with EP inference provided higher accuracy than alternative methods like Laplace approximation, despite higher computational cost.
  • The method successfully captured discontinuities in the APD 90 response surface across varying drug block parameters in the O’Hara model.
  • The approach is generalizable to other biomarkers and biophysical models that exhibit bifurcations and discontinuous responses.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.