[Paper Review] Geant4 simulations of soft proton scattering in X-ray optics. A tentative validation using laboratory measurements
This paper presents a Geant4 implementation of the Remizovich model for soft proton scattering in X-ray optics, validated against laboratory measurements at 250 keV. It finds that single scattering and the Remizovich model best reproduce experimental scattering efficiency, though energy losses remain underestimated; multiple scattering fails to model soft proton funnelling, and no model fully captures low-energy behavior due to data limitations at <200 keV and small angles.
Low energy protons (< 300 keV) can enter the field of view of X-ray space telescopes, scatter at small incident angles, and deposit energy on the detector, causing intense background flares at the focal plane or in the most extreme cases, damaging the X-ray detector. A correct modelization of the physics process responsible for the grazing angle scattering processes is mandatory to evaluate the impact of such events on the performance of future X-ray telescopes as the ESA ATHENA mission. For the first time the Remizovich model, in the approximation of no energy losses, is implemented top of the Geant4 release 10.2. Both the new scattering physics and the built-in Coulomb scattering are used to reproduce the latest experimental results on grazing angle proton scattering. At 250 keV multiple scattering delivers large proton angles and it is not consistent with the observation. Among the tested models, the single scattering seems to better reproduce the scattering efficiency at the three energies but energy loss obtained at small scattering angles is significantly lower than the experimental values. In general, the energy losses obtained in the experiment are higher than what obtained by the simulation. The experimental data are not completely representative of the soft proton scattering experienced by current X-ray telescopes because of the lack of measurements at low energies (< 200 keV) and small reflection angles, so we are not able to address any of the tested models as the one that can certainly reproduce the scattering behavior of low energy protons expected for the ATHENA mission. We can, however, discard multiple scattering as the model able to reproduce soft proton funneling, and affirm that Coulomb single scattering can represent, until further measurements, the best approximation of the proton scattered angular distribution at the exit of X-ray optics.
Motivation & Objective
- To implement and validate the Remizovich model for grazing-angle soft proton scattering in Geant4 for use in X-ray space telescope background simulations.
- To assess the performance of the Remizovich model, single scattering, and multiple scattering models against recent laboratory measurements of proton scattering at 250 keV.
- To determine which physics model best reproduces experimental scattering efficiency and energy loss in X-ray mirror shells.
- To support the development of accurate radiation background models for future X-ray missions such as ESA's ATHENA.
- To identify limitations in current models and data, particularly at low energies (<200 keV) and small scattering angles, for future refinement.
Proposed method
- Implemented the Remizovich model in Geant4 using the Boltzmann transport equation with diffuse approximation and continuous slowing down, allowing for constant energy loss per interaction.
- Verified the new model against theoretical probability distributions and independent ray-tracing simulations.
- Compared the Remizovich model and single scattering (SS) with multiple scattering (MSC) and existing Geant4 physics lists (opt3/opt4) in simulating the same experimental setup.
- Optimized the Geant4 algorithm using loop-level parallelization and fine-tuned angle resolution, achieving ~50% CPU time gain.
- Used experimental data from 2015ExA….39..343D on proton angular and energy distributions after grazing incidence on X-ray mirror shells.
- Evaluated model performance by comparing simulated scattering efficiency and energy loss to measured values at 250 keV.
Experimental results
Research questions
- RQ1Can the Remizovich model, implemented in Geant4, accurately reproduce the angular and energy distribution of soft protons scattered at grazing angles on X-ray mirror shells?
- RQ2How do the simulated scattering efficiencies of the Remizovich model, single scattering, and multiple scattering compare to experimental measurements at 250 keV?
- RQ3To what extent do the simulated energy losses in the models match the experimentally observed energy losses at small scattering angles?
- RQ4Why does multiple scattering fail to reproduce soft proton funnelling in X-ray optics, and what are the implications for background modeling in X-ray telescopes?
- RQ5Can the current models be trusted for simulating soft proton backgrounds in future missions like ATHENA, given the lack of data at low energies and small angles?
Key findings
- The Remizovich model and single scattering (SS) show good agreement with experimental scattering efficiency at 250 keV, except at very small angles (<1°), where simulations slightly underestimate efficiency.
- Single scattering produces the closest match to experimental scattering efficiency at small angles, but predicts energy losses that are a factor of 10 lower than measured values.
- Multiple scattering (MSC) fails to reproduce the observed angular distribution and cannot simulate soft proton funnelling, rendering it unsuitable for this application.
- At large scattering angles, both the Remizovich and SS models yield consistent scattering efficiencies.
- The azimuthally focused Firsov model with φ=0 overestimates the scattering distribution by more than a factor of 10, indicating it is not suitable for this setup.
- No significant differences were found between the opt3 and opt4 settings for multiple scattering, suggesting they perform similarly in this context.